Page 31
FIGURE 23- “S” EKT WIRE ROUTING 10.21 An optional handset hanger kit (HWMA) is also required to convert the optional EKTs for wall mounting. 10.22 All optional EKTs are mounted in the same manner, and they may be mounted on a wall or any other flat, vertical surface to which the base can be secured. When selecting the mounting site, consider the EKT weight and the additional stresses to which the mounting will be subjected. 10.23 Mounting screws or mollies, appropriate for the surface on which...
Page 32
INSTALLATION SECTION 100-003-200 JULY 1994 . - 10.34 install the handset hanger into place and tighten the screws. Reinstall the number card and card cover. FIGURE 27-HANDSET HANGER KIT 10.35 An optional 13-ft. handset cord is avail- able from your Toshiba supplier, and it is sug- gested that this cord be used when wall-mounting an EKT. 10.40 EKT Connections 10.41 Connect the appropriate length line cord to the modular connector, route the cord to the EKT and connect to the EKT modular...
Page 33
l The SET LED and MW/FL LED on station j) Depress the wj key. 17 will go off. . DND LED: off. 12 SYSTEM TEST PROCEDURES 12.00 1 O-key S EKT Functional Check 12.01 In order to verify the basic system func- tions and confirm the proper functioning of the EKT itself, perform the following test procedure at each station equipped with a IO-key S EKT, begin- ning with station 10. k) Depress the m key. l CO 1 LED: l-use flash. l SPKR LED: on steady. l Listen for CO/PBX dial tone via EKT speaker....
Page 34
lNSTAU.ATlON SECTION 100-003-200 JULY 1984 check for the standard EKT; repeat the procedure for all standard EKTs in the system. See Paragraph 12.10 for optional EKT functional checks. 12.10 Optional EKT Functional Check 12.11 In order to verify the optional EKT’s func- tions and confirm the proper functioning of the EKT itself, perform the following test procedure on each optional EKT. 12.12 With handset on-hook: a) b) d d) d f) Depress the m key. 0 INT LED: l-use flash. l SPKR LED:...
Page 35
-.‘v) Hold down the [ml key, and set the handset back on-hook. 0 INT LED: l-use flash. l SPKR & MIC LEDs: on steady. w) Tap the EKT microphone and verify that the sound can be heard via the called EKT speaker. x) Depress the (MUIE/MICI key while tapping the microphone and verify that the sound cannot be heard via the called EKT speaker (MIC LED off momentarily-if equipped). y) Depress the m key. . INT LED: off. . SPKR & MIC LEDs: off. 12.13 This completes the station functional check for...
Page 36
INSTALLATION ‘. SECTION 100-003-200 JULY 1984 on the type of speaker used, the conductor resist- ante, and the desired volume. 13.32 Install the AEPU PCB per Paragraph 07.30. The 8R output impedance must be selected with the SW2 switch on the MMAU (Figure 31). 13.33 Connect the external speaker to the two 81600 terminals on the modular connector panel on the MKSU. 13.34 Adjust the speaker volume with the volume control on the AEPU PC8 (Figure 32). FIGURE 31-MMAU SW2 SWITCH FIGURE 32-AEPU...
Page 37
INSTALLATION SECTION 100-003-200 JULY 1984 13.51 The power failure transfer feature is designed, upon power failure, to switch the sys- tem CO lines directly to dedicated- customer- provided conventional telephones. 13.52 The MKSU must be equipped with the APFU PC6 and the power failure telephones must be directly compatible with the CO lines. 13.53 A simplified diagram of the power failure transfer feature is shown in Figure 33. 13.54 The power failure telephones are con- nected to the...
Page 38
6c TOSHIBA SYSTEM PRACTICES ELECTRONIC KEY TELEPHONE SYSTEM MPSA-512 INSTALLATION SECTION 100-003-250 JULY 1984 Strata S POWER SUPPLY (MPSA-512) a - .. -- INSTALLATION INSTRUCTIONS
Page 39
TOSHIBA SYSTEM PRACTICES ELECTRONIC KEY TELEPHONE SYSTEM Strata S MPSA-512 INSTALLATION SECTION 100-003-250 JULY 1984 MPSA-512 INSTALLATION INSTRUCTIONS TABLE of CONTENTS PARAGRAPH SUBJECT PAGE TABLE of CONTENTS ........................ i ILLUSTRATION LIST ......................... i 01 GENERAL ............................. 1 01 .oo Description ........................... 1 01.10 Mounting the MPSA ....................... 1 01.20 Fuses .............................. 1 02 POWER CONNECTION...
Page 40
-. 01 -GENERAL ’ 01 .OO Description 01 .Ol The MPSA-512 power supply is perman- ently configured for wall mounting. Its design will not allow proper cooling if it is not mounted upright as shown in Figure 1. FIGURE l-MPSA-512 01.02 Unpack and inspect the power supply and the enclosed hardware. Examine the package and make careful note of any visible damage. If any damage is found, bring it to the attention of the delivery carrier and make the proper claims. 01.03 Check the hardware list; if...