Home
>
Toshiba
>
Communications System
>
Toshiba Strata S Electronic Key Telephone System Installation And Maintenance Manual
Toshiba Strata S Electronic Key Telephone System Installation And Maintenance Manual
Here you can view all the pages of manual Toshiba Strata S Electronic Key Telephone System Installation And Maintenance Manual. The Toshiba manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 21
--. 01. GENERAL I 01.01 This section describes the installation procedures necessary to ensure proper operation of the Strata S system. 02 PACKING 02.00 Inspection 02.01 When a Strata S system is received, examine all packages and carefully note any vis- ible damage. If any damage is found, bring it to the attention of the delivery carrier and make the proper claims. 02.02 Check the number of cartons and the contents of the Strata S shipment against the purchase order and packing slip. If...
Page 22
INSTALLATION SECTION 100-003-200 JULY 1994 5) Knockouts are provided on the top and bottom of the side covers to permit cables to enter the MKSU. Remove the appropriate knockouts. FIGURE 1 -SIDE COVERS 6) Reinstall the side covers. 7) Refer to Section 100-003-250, MPSA-512 Installation (or Section 100-003-255, MPSA- 200 installation), and follow the appropriate instructions for installing the selected MPSA. A completed installation with an MPSA-512 should aooear as shown in Fiaure 2....
Page 23
_.. amplifier is required. Eight ohms is used when the AEPU PCB is installed. The output will then be via a 3-watt amplifier on the AEPU. FIGURE 4 EXTERNAL PAGE TERMINALS 06.02 External page options are selected using the SW2 switch located on the MMAU (Figure 5). Decide if the 8 or 6DOQ impedance is required and then make the selection by positioning SW2 to “8” or FIGURE 5-MMAU SWITCHES 06.10 Music-on-hold Option Selection 06.11 A customer-provided MOH program source or the optional AMOU...
Page 24
INSTALLATION SECTION 100-003-200 JULY 1994 v.. vided, as shown in Figure 7. FIGURE 7-MOUNTED AMOU PCB 07.12 Connect the AMOU cable to PB on the MMAU PCB Der Figure 8. FIGURE 8 AMOWMMAU CABLE CONNECTION 07.20 APFU (Power Failure Transfer Unit) Installation 07.21 Secure the APFU to the upper part of the MKSU right side panel with the two screws pro- vided, as shown in Figure 9. 07.22 Connect the 8-pin jack (from the OPL jack) into the Pl plug on,the APFU (Figure 10). FIGURE g--MOUNTED...
Page 25
e.. shown in Figure 11. Mount the PCB on the lo-pin connectors P5 and P6 (note the “6” arrow on the AEPU and pin alignment when positioning the PCB) and secure it with the two screws provided (Figure 11). FIGURE 1 l-MOUNTED AEPU 07.32 Note the location of the volume control in Figure 11. It will be necessary to leave the MKSU cover off until this has been adjusted per Para- graph 11.30. 07.40 MKSU Cover Installation 07.41 Reinstall the MKSU top cover in the reverse order the instructions...
Page 26
INSTALLATION SECTION 100-003-200 JULY 1994 -.. - 6) If a reading of OV on one terminal and a read- ing of 90 - 130 VAC on the other terminal is obtained, remove both probes from the outlet. 7) Set the meter on the “OHMS/Rxl” scale, place one probe on the GND terminal and the other probe on the terminal which produced a reading of OV. A reading of less than IS2 should be obtained. If a reading of more than 1 R is obtained, the outlet is not adequately grounded. 8) If the above tests show...
Page 27
-‘09.02 A 25-pair &ale-amphenoliended cable is connecteddirectlytothefemale-amphenol-connec- tor on the riqht side connector panel (Figure 13). FIGURE 13-MKSU CABLE CLAMPING 09.03 Secure the cable to the panel using the plastic strap and cable clamp provided. 09.04 Use the industry-standard color code sequence and terminate the cable on the MDF block as shown in Figure 14. 09.10 Station Cable Connections 09.11 Terminate the individual 2-pair station cables consecutively on the MDF block;...
Page 28
lNSTALl.ATlON . SECTION 100-003-200 JlJlv1994 : I-pair JACKETED STATION CABLE L -El-l- Ynbu” %R “7r: -c --i BRIDGING -7 CLIPS idOT USED I 66M160 SPLIT BLOCK MODULAR STATION BLOCK TO MKSU II 5432 - . I .... J MODULAR CORD STATION l-IcjUHt 14-MUi- tK I WlHlNIj (EKTs) may be used in the Strata system. The standard EKT (Figure 16). known as the 1 O-key “S” EKT, is equipped with three permanentlyded- icated keys and ten line/feature keys. The three optional (full speakerphone) EKTs...
Page 29
I ; ‘. _. -. I FIGURE 16-l O-key “S” EKT ‘.. INSTALLATION SECTION 100-003-200 JULY 1984 I FIGURE 17-lo-key SPEAKERPHONE EKT FIGURE 18-BLF EKT FIGURE 19-20-key EKT for intercom access, and the remaining keys for feature operation. 10.03 All three optional EKTs share the same external dimensions: 10.05 The optional 1 O-key BLF EKT provides the same features as those listed in Paragraph 10.04, plus an LED indication on which stations are in use. Height: 4.0 inches (102 mm) Width: 8.8...
Page 30
INSTALLATION SECTION 100-003-200 JULY 1994 . - PAU H - FIGURE 20-KEY LAYOUT 10.10 1 O-key S EKT Wall Mounting 10.11 An optional ‘SKWM” kit is required to convert the IO-key S EKT for wall mounting. The “SKWM” kit consists of a metal wall bracket and a handset hanger kit. 10.12 TheEKTmaybemountedonawallorany other flat, vertical surface to which the wall bracket can be secured. When selecting the mounting site, consider the EKT weight and the additional stresses to which the mounting will...