E -05.02 A functio.nal block diagram of the Strata S MKSU is shown in Figure 9; it con- sists of the main PCB (MMAU), which includes a station interface and central control equipment, and a CO interface (ACOU). The optional Paging Amplifier module (AEPU), internal music-on-hold .source (AMOU), and Power Failure module(APFU) are also shown. 05.03 Connections between the station voice GENERAL DESCRIPTION ‘. SECTION 100-003-l 00 JULY 1994 lines and the CO lines are via theswitching matrix...
Page 12
GENERAL DESCRIPTION SECTION 100-003-l 00 JULY 1984 e.. 06 SYSTEM CONFIGURATION 06.00 Key Service Unit 06.01 Completewith all options, the MKSU util- izes five circuit boards. The names and functions of the PCBs are: ACOU (MF or DP): An interface between the MKSU and the pub- lic telephone network or PBX lines. Ring detec- tion, hold and dial outpulsing for three circuits are performed by this PCB. Depending upon local CO requirements, an MF or DP type of ACOU will be provided (MF for DTMF...
Page 13
-..06.12 An optional battery back-up unit (PBBU) is available for the MPSA-200. With the optional battery back-up assembly installed, all functions of the Strata S system. will continue to operate for several hours (the actual time period is in direct ratio to the type and size of batteries selected) after a loss of normal electrical power. No calls will be disconnected during switch-over to battery power. FIGURE 1 l-l O-key “S” EKT 06.20 Station Equipment 06.21 The principal components of the...
Page 14
GENEML DESCRlPTlDN SECTION 100-003-l 00 aJ~lY 1994 _ _ 06.24 The optional lo-key BLF EKT (Figure 14) provides the same features as those listed in Para- graph 06.23, plus an LED indication on which stations are in use. I - : . . 06.26 All EKTs feature modular handset cords and are connected to the system via 4-conductor modular line cords. . . 06.27 All EKTs are easily converted for wall mounting with an optional kit. 06.30 Installation 06.31 External devices are connected to the MKSU via...
Page 15
--.Alternate Point Answer: CO/PBX or intercom calls can be answered from any station. Automatic Dialing-System: This standard feature allows 40 numbers to be stored in the system memory. After selecting an outgoing line, any station user can cause one of the stored numbers to be outpulsed by dialing the proper address code. Automatic Hold Recall: A CO line placed on hold by any station will recall that station after a programmable period of time. Automatic Privacy: Privacy is automatic on...
Page 16
GENERAL OESCRlWlON SECTION 100-003-l 00 JULY 1984 e.. - Private CO Lines: Restrictions may be programmed into the sys- tem so that selected CO line(s) may appear only on selected station(s). Repeat Last Number Dialed: The last number dialed by each station is always stored by the system and will be dialed automatically whenever the station user selects an outgoing line and depresses the q key. Toll Restriction: Selectively programmed on a per-station, per- line basis. Strata S performs...
Page 17
f a- GENERAL DESCRIPTION SECTION 100-003-l 00 JULY 1994 each station. A station in the DND mode will show as busy. ZO-key Executive EKT: An optional executive unit provides handsfree answerback, full speakerphone capability and, via 10 additional feature keys, automatic dial- ing access, four one-touch automatic dialing telephone numbers, redial last number dialed, a pause key, or may be used as a DSS station. External Page Amplifier: This optional external page 3-watt amplifier (AEPU PCB)...
Page 18
- TOSHIBA SYSTEM PRACTICES ELECTRONIC KEY TELEPHONE SYSTEM INSTALLATION SECTION 100-003-200 JULY 1984 , StrataS --. INSTALLATION INSTRUCTIONS
Page 19
INSTALLATION SECTION 100-003-200 JULY 1984 TOSHIBA SYSTEM PRACTICES ELECTRONIC KEY TELEPHONE SYSTEM _.. Strata S INSTALLATION INSTRUCTIONS TABLE of CONTENTS PARAGRAPH SUBJECT PAGE 01 02 02.00 03 03.00 03.10 03.20 03.30 04 04.00 05 o:.:o 06.10 07 07.00 07.10 07.20 07.30 07.40 08 08.00 08.10 09 09.00 09.10 09.20 09.30 10 10.00 10.10 10.20 10.30 10.40 11 11.10 12 12.00 12.10 12.20 13 13.00 13.10 13.20 13.30 13.40 13.50 TABLE of CONTENTS...
Page 20
TOSHIBA SYSTEM PRACTICES ELECTRONIC KEY TELEPHONE SYSTEM INSTALLATION SECTION 100-003-200 JULY 1984 w.. NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 :: 33 34 Strata S INSTALLATION INSTRUCTIONS ILLUSTRATION LIST TITLE PAGE SideCovers ................................................................. 2 WallMountedMKSU ........................................................ 2 MKSUwith PCBs...