TABLE 19-5a (continued) 
7 7. Dialing was not complete when q was entered. A second q is required. 
12. Enter the port number (TNNX) of the trunk (B) to be tested. 
73. Requested trunk was idle and has been 
seized. 
14. Requested trunk (B) is busy. 
15. Requested trunk (B) does not exist in the system. 
16. Enter the DN that should be dialed by the trunk under test, followed by a 
q , 
17. After the dialing is complete, the audio from the trunk...

Page 272

PROGRAMMINGPROCEDURES 
SECTION 200-255-319 
FEBRUARY1992 
TABLE19-6 
DISKDRIVEOPERATIONERRORCODES 
Error Codes 
Program Name: Floppy Disk Drive Error 
Error Code Meaning 
ERFD 01 
File is closed. 
ERFD 02 Read error. 
ERFD 03 
ERFD 04 
ERFD 05 Write error. 
Directory is full. 
Disk is full. 
I ERFD 06 
I End-of-file error. 
1 ERFD 07 1 Disk drive is not readv. 
I ERFD 08 
I Incorrect version number. 
I 
ERFD 09 
ERFD 10 File is write-protected. 
File not found. 
ERFD 11 
ERFD 12 
ERFD FF Volume not...

Page 273

PERCEPTIONea, 
LCFVTR PROGRAMMING GUIDE 
MARCH 1991 
Perception& 63 ex 
DIGITAL HYBRID PBX 
APPENDIX #2 
LEAST COST ROUTING (LCR) 
and 
TOLL RESTRICTION (TR) 
PROGRAMMING GUIDE  

Page 274

PERCEPTIONeh, 
LCR/TR PROGRAMMING GUIDE 
MARCH 1991 
PARAGRAPH 
1. 
2. 
2.00 
2.10 
3. 
3.00 
4. 
4.00 
5. 
5.00 
6. 
6.00 
6.10 
6.20 
7. 
7.00 
PERCEPTION,,, 
LCR/TR PROGRAMMING GUIDE 
TABLE OF CONTENTS 
SUBJECT PAGE 
INTRODUCTION .............................................................................................. 
GENERAL DESCRIPTION ............................................................................... 
Least Cost Routing (LCR)...

Page 275

1. INTRODUCTION 
1 .Ol This document has two main purposes: a) to 
describe the Least Cost Routing (LCR) and Toll 
Restriction (TR) features, and b) to serve as a 
supplement to Section 200-255-300, System Pro- 
gramming, in order to guide the service technician 
in LCRflR programming. Various examples, tables, 
and flowcharts are provided to clarify feature expla- 
nations. 
a .02 This document assumes that the reader is 
familiar with PERCEPTIONekex programming 
procedures and the mnemonics used with...

Page 276

PERCEPTIONea, 
LCWTR PROGRAMMING GUIDE 
MARCH 1991 
to restrict calls to the local central office operator, 
international calls, and/or long distance directory 
assistance. 
2.13 Eight different TR classes (CLS 0 w 7) can be 
programmed in the previously-described manner. 
+I+ Also, CLS 8 restricts all I+ and a + calls. 
2.14 All stations programmed for TOL = NONE will 
have no restrictions. The TOL parameter (TR class 
number) is located in the 
DEKT, DSlT, and DTGP 
(TIECCSA Trunks) Programs. 
2.15...

Page 277

4) 
local call route table (LCR). 
Long distance directory assistance (555): This 
is a call using any area code (or no area code) 
plus 5551212. If allowed, this type of call is 
routed via the LDI route table, as indicated in the 
PAR table, or via the route table (DAC = N) to 
which this area code is assigned. 
NOTE: 
When a DDD callis dialed, 
needed before the area 
cause the local operator to be connected. 
4. SPECIAL COMMON CARRIER 
4.00 Description 
4.01 Dialing extra digits to access the Special...

Page 278

PERCEPTIONeh, 
LCR/TR PROGRAMMING GUIDE 
MARCH 1991 
CUSTOMER DATA PROGRAMMING FLOWCHART 
To 
0 
Pate 6 NO 
4 ------ 
YES 
; 
Assign an LCR 
accesscode 
(LCWDACD). 
Telecom 
environment and - - - - - - Define parameters 
miscellaneous (PAR/DLCl). 
parameters. 
Comments: 
Assign area 
codes to - - - - 
respective 
route tables. 
YES NOTE: 
in any application 
where an SPCC is to 
be automatically 
dialed and accessed, 
LCR must be used. 
i NO 
AOC table is 
area code requires 
more than one 
route table....

Page 279

PERCEPTIONeb, 
LCR/TR PROGRAMMING GUIDE 
MARCH 1991 
CUSTOMER DATA PROGRAMMING FLOWCHART (continued) 
List the office codes 
for the respective area 
codes that belong to a 
route table other than 
that shown in the ACT 
table (AOC/DLCl). 
I- 
Deny the LCR 
class as required 
for the respective 
class of service 
(DCOS).  one LCR class NO 
NOTE: 
Always complete 
the SCHB prompt 
even when schedule 
B is not used. Define the route 
tables for all the 
assigned ACT and 
AOC tables 
(RTB/DLC2). 
I 
Modify...

Page 280

PERCEPTIONek, 
LCR/TR PROGRAMMING GUIDE 
MARCH 1991 
CUSTOMER DATA PROGRAMMING FLOWCHART (continued) 
From 
NO 
Comments: 
Absorb the SPCC 
authorization code _ _ _ - - - 
1 anator AL I 
‘^../ 
(l’AH/U I VI 
I Define AUTHl 
*. 
- * IT,,2 
paramebl (s) 
-. - ‘--v. 
NO 
toll restriction? From 
r A 
-0 
Page 4 
LCR programmed? NO Define the TOL 
arameters 
(PAWDTOL). 
Assign a TR class 
restricted stations 4 
and TIE trunks 
(DSlT/DEKT/DTGP). 
Define each 
TR class used 
(CLSDTOL). 
-6-  