Home > Tone Commander > Telephone > Tone Commander 30e120 Installation Instructions

Tone Commander 30e120 Installation Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Tone Commander 30e120 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 24 Tone Commander manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							CONNECTOR #5 CONNECTOR #6
    PIN NO.
    WIRE COLORDESIGNATION(left)DESIGNATION(right)
    26·······WHT-BLU·······T61 ··········T76
    1·······BLU-WHT·······R61 ··········R76
    27·······WHT-ORN·······T62 ··········T77
    2·······ORN-WHT·······R62 ··········R77
    28·······WHT-GRN·······T63 ··········T78
    3·······GRN-WHT·······R63 ··········R78
    29·······WHT-BRN·······T64 ··········T79
    4·······BRN-WHT·······R64 ··········R79
    30·······WHT-SLT·······T65 ··········T80
    5·······SLT-WHT·······R65 ··········R80
    31·······RED-BLU·······T66 ··········T81
    6·······BLU-RED·······R66 ··········R81
    32·······RED-ORN·······T67 ··········T82
    7·······ORN-RED·······R67 ··········R82
    33·······RED-GRN·······T68 ··········T83
    8·······GRN-RED·······R68 ··········R83
    34·······RED-BRN·······T69 ··········T84
    9·······BRN-RED·······R69 ··········R84
    35·······RED-SLT·······T70 ··········T85
    10·······SLT-RED·······R70 ··········R85
    36·······BLK-BLU·······T71 ··········T86
    11·······BLU-BLK·······R71 ··········R86
    37·······BLK-ORN·······T72 ··········T87
    12·······ORN-BLK·······R72 ··········R87
    38·······BLK-GRN·······T73 ··········T88
    13·······GRN-BLK·······R73 ··········R88
    39·······BLK-BRN·······T74 ··········T89
    14·······BRN-BLK·······R74 ··········R89
    40·······BLK-SLT········T75 ··········T90
    15·······SLT-BLK········R75 ··········R90
    41·······YEL-BLU······· – ·········· –
    16·······BLU-YEL······· – ·········· –
    42·······YEL-ORN······· – ·········· –
    17·······ORN-YEL······· – ·········· –
    43·······YEL-GRN······· – ·········· –
    18·······GRN-YEL······· – ·········· –
    44·······YEL-BRN······· – ·········· –
    19·······BRN-YEL······· – ·········· –
    45·······YEL-SLT········ – ·········· –
    20·······SLT-YEL········ – ·········· –
    46·······VIO-BLU········ – ·········· –
    21·······BLU-VIO········ – ·········· –
    47·······VIO-ORN······· – ·········· –
    22·······ORN-VIO······· – ·········· –
    48·······VIO-GRN······· – ·········· –
    23·······GRN-VIO······· – ·········· –
    49·······VIO-BRN······· – ·········· –
    24·······BRN-VIO······· – ·········· –
    50·······VIO-SLT········ – ·········· –
    25·······SLT-VIO········ – ·········· –
    13-102499 Rev. GPage 21
    Tone Commander 30e120 Installation Instructions
    Table 5
    120 Block #3
    Pinout
    station
    monitor
    circuits 
    						
    							CONNECTOR #7 CONNECTOR #8
    PIN NO.
    WIRE COLORDESIGNATION(left)DESIGNATION(right)
    26·······WHT-BLU·······T91 ··········T106
    1·······BLU-WHT·······R91 ··········R106
    27·······WHT-ORN·······T92 ··········T107
    2·······ORN-WHT·······R92 ··········R107
    28·······WHT-GRN·······T93 ··········T108
    3·······GRN-WHT·······R93 ··········R108
    29·······WHT-BRN·······T94 ··········T109
    4·······BRN-WHT·······R94 ··········R109
    30·······WHT-SLT·······T95 ··········T110
    5·······SLT-WHT·······R95 ··········R110
    31·······RED-BLU·······T96 ··········T111
    6·······BLU-RED·······R96 ··········R111
    32·······RED-ORN·······T97 ··········T112
    7·······ORN-RED·······R97 ··········R112
    33·······RED-GRN·······T98 ··········T113
    8·······GRN-RED·······R98 ··········R113
    34·······RED-BRN·······T99 ··········T114
    9·······BRN-RED·······R99 ··········R114
    35·······RED-SLT·······T100··········T115
    10·······SLT-RED·······R100··········R115
    36·······BLK-BLU·······T101··········T116
    11·······BLU-BLK·······R101··········R116
    37·······BLK-ORN·······T102··········T117
    12·······ORN-BLK·······R102··········R117
    38·······BLK-GRN·······T103··········T118
    13·······GRN-BLK·······R103··········R118
    39·······BLK-BRN·······T104··········T119
    14·······BRN-BLK·······R104··········R119
    40·······BLK-SLT········T105··········T120
    15·······SLT-BLK········R105··········R120
    41·······YEL-BLU······· – ·········· –
    16·······BLU-YEL······· – ·········· –
    42·······YEL-ORN······· – ·········· –
    17·······ORN-YEL······· – ·········· –
    43·······YEL-GRN······· – ·········· –
    18·······GRN-YEL······· – ·········· –
    44·······YEL-BRN······· – ·········· –
    19·······BRN-YEL······· – ·········· –
    45·······YEL-SLT········ – ·········· –
    20·······SLT-YEL········ – ·········· –
    46·······VIO-BLU········ – ·········· –
    21·······BLU-VIO········ – ·········· –
    47·······VIO-ORN······· – ·········· –
    22·······ORN-VIO······· – ·········· –
    48·······VIO-GRN······· – ·········· –
    23·······GRN-VIO······· – ·········· –
    49·······VIO-BRN······· – ·········· –
    24·······BRN-VIO······· – ·········· –
    50·······VIO-SLT········ – ·········· –
    25·······SLT-VIO········ – ·········· –
    Page 2213-102499 Rev. G
    Tone Commander 30e120 Installation Instructions
    Table 6
    120 Block #4
    Pinout
    station
    monitor
    circuits 
    						
    							Data Link Cable
    1. Plug the supplied data link cable to the 30e port on the 120 CPU.
    2. Plug the other end of the cable to the lower 120 port on the 30e CPU.
    3. Route the cable through the slots at the bottom of the CPU housings.
    4.Excess cable must be stored in the 120 CPU as shown to assure FCC Part 15 compliance.
    Secure with a cable tie.
    5. If this installation has two 120 CPUs (121-240 stations), connect the second 120 CPU to the upper
    120 port on the 30e CPU.
    Page 2413-102499 Rev. G
    Tone Commander 30e120 Installation Instructions
    Figure 3 
    						
    							Reference Grounding
    1. Connect telco or PABX ground to the GRD pin on the bottom of 30e block #2.
    2. For each 120 CPU, connect telco or PABX ground to the GRD pin on the bottom right of 120 block #1.
    These connections may be daisy chained as shown.
    DO NOT connect this reference ground to the metal housing of any CPU or power supply!
    CPU Chassis Grounding
    This ground connection is required for safety and EMI shielding. It is usually provided by the 3rd wire on
    the CPU power cords. If the integrity of the power outlet ground is questionable, use the ground
    connection shown below for each 30e and 120 CPU.
    1. Connect a solid copper #10 or #12 AWG wire to the ground terminal on the CPU. The wire should be
    tightly clamped between the ground screw and the cup washer.
    2. Connect the wire to an approved ground, such as MGN (multi-grounded neutral) from the power lines,
    building ground, a metallic cold water pipe, or a grounding rod.
    13-102499 Rev. GPage 25
    Tone Commander 30e120 Installation Instructions
    Reference grounding of the system is necessary for proper operation.
    Figure 4
    Figure 5 
    						
    							Connections to Telco/PABX Lines
    Line Testing
    Connect a test telephone to each line; verify the presence of dial tone, and break dial tone by dialing a
    number.
    The 30e allows DTMF tone dialing only – refer to the SYSTEM DESCRIPTION - Telco/PABX Requirements
    section.
    Test any additional features ordered with the lines. Open circuit voltage must be approximately 48 volts.
    Station Connections
    Page 2613-102499 Rev. G
    Tone Commander 30e120 Installation Instructions
    1. Connect Tip and Ring of each line to the associatedT
    andRpair on the right side of 30e block #1.
    If the 30e is used with a key system, connect to the
    C.O. side of the line cards.
    2. If this installation has stations in parallel with console
    lines, the stations should be connected to Tip and
    Ring at the telco/PABX block.
    Figure 6
    Figure 7
    ConnectTandRon the 120 blocks to Tip and
    Ring of each station to be monitored. The 120
    connects in parallel with the station sets. 
    						
    							Console Cable Installation
    30e Console Cables
    Console Positions #1 and #2
    Wall
    Jack
    PinoutWall Jack
    Typical
    Wire ColorConsole #1
    Designation
    (connector 1)Console #2
    Designation
    (connector 1)Typical 3 Pair
    Console Cable
    Wire Color(actual
    wire color)
    1 WHT 1C3 (WHT-GRN) 2C3 (RED-BLU) WHT-GRN
    2 BLK 1C1 (WHT-ORN) 2C1 (WHT-SLT) WHT-ORN
    3 RED 1RN (BLU-WHT) 2RN (BRN-WHT) BLU-WHT
    4 GRN 1TN (WHT-BLU) 2TN (WHT-BRN) WHT-BLU
    5 YEL 1C2 (ORN-WHT) 2C2 (SLT-WHT) ORN-WHT
    6 BLU 1C4 (GRN-WHT) 2C4 (BLU-RED) GRN-WHT
    Table 8– 30e Console “Voice/Data” Jack Pinout, Console Positions #1 and #2
    13-102499 Rev. GPage 27
    Tone Commander 30e120 Installation Instructions
    Figure 8 
    						
    							Wall
    Jack
    PinoutWall Jack
    Typical
    Wire ColorConsole #1
    DesignationConsole #2
    DesignationTypical 3 Pair
    Console Cable
    Wire Color(actual
    wire color)
    1 WHT 1C+ (YEL-BLU) 2C+ (YEL-SLT) WHT-GRN
    2 BLK 1C+ (BLK-SLT) 2C+ (YEL-BRN) WHT-ORN
    3 RED 1C- (BRN-BLK) 2C- (GRN-YEL) BLU-WHT
    4 GRN 1C+ (BLK-BRN) 2C+ (YEL-GRN) WHT-BLU
    5 YEL 1C- (SLY-BLK) 2C- (BRN-YEL) ORN-WHT
    6 BLU 1C- (BLU-YEL) 2C- (SLT-YEL) GRN-WHT
    Table 9 –30e Console “Power” Jack Pinout, Console Positions #1 and #2
    All 30e console cables from positions #1 and #2 connect to 30e block #2. The total length of each console
    cable, including line cord and equipment room cross connects, must not exceed 500 feet.
    1. Install two 6 position, 6 contact modular telephone jacks within 6 feet of the console.
    2. Label the jacks 30e voice/data and 30e power.
    3. Connect a 3 pair cable to each jack and run them to the equipment room.
    IMPORTANT– Whenever nonkey adapters are used in conjunction with existing multipair cable, verify
    that the adapters conform to Tables 8 and 9 above.
    4.Only if the colors of your cables differ from the typical colors: fill out Tables 8 and 9 with the actual wire
    colors of the cables for each connection.
    5. Punch down the voice/data cable to block #2 as listed in the Console #1 Designation column in
    Table 8.
    6. Punch down the power cable to block #2 as listed in the Console #1 Designation column in Table 9.
    7. If the system has two attendant positions, punch down the second consoles cables to the pins listed in
    the Console #2 Designation columns of Tables 8 and 9.
    Page 2813-102499 Rev. G
    Tone Commander 30e120 Installation Instructions
    CAUTION– Before connecting Voice/Data and Power, make sure that the CPU is powered down! 
    						
    							Console Positions #3 and #4
    Wall
    Jack
    PinoutWall Jack
    Typical
    Wire ColorConsole #3
    DesignationConsole #4
    DesignationTypical 3 Pair
    Console Cable
    Wire Color(actual
    wire color)
    1 WHT 3C3 (RED-BRN) 4C3 (BLK-ORN) WHT-GRN
    2 BLK 3C1 (RED-GRN) 4C1 (BLK-BLU) WHT-ORN
    3 RED 3RN (ORN-RED) 4RN (SLT-RED) BLU-WHT
    4 GRN 3TN (RED-ORN) 4TN (RED-SLT) WHT-BLU
    5 YEL 3C2 (GRN-RED) 4C2 (BLU-BLK) ORN-WHT
    6 BLU 3C4 (BRN-RED) 4C4 (ORN-BLK) GRN-WHT
    Table 10 –30e Console “Voice/Data” Jack Pinout, Console Positions #3 and #4
    Wall
    Jack
    PinoutWall Jack
    Typical
    Wire ColorConsole #3
    DesignationConsole #4
    DesignationTypical 3 Pair
    Console Cable
    Wire Color(actual
    wire color)
    1 WHT 3C+ (WHT-GRN) 4C+ (RED-GRN) WHT-GRN
    2 BLK 3C+ (WHT-ORN) 4C+ (RED-ORN) WHT-ORN
    3 RED 3C- (BLU-WHT) 4C- (BLU-RED) BLU-WHT
    4 GRN 3C+ (WHT-BLU) 4C+ (RED-BLU) WHT-BLU
    5 YEL 3C- (ORN-WHT) 4C- (ORN-RED) ORN-WHT
    6 BLU 3C- (GRN-WHT) 4C- (GRN-RED) GRN-WHT
    Table 11 –30e Console “Power” Jack Pinout, Console Positions #3 and #4
    A PSE-3 power supply is required for these consoles. Each supply can power three consoles, either 30e or
    120 models.All PSE-3s must be powered from the same outlet box or power strip as the 30e and 120
    CPUs.
    The power cables from 30e consoles at positions #3 and #4 must connect to the power supply block. The
    voice/data cables connect to 30e block #2.
    The total length of each console cable, including line cord and equipment room cross connects, must not
    exceed 500 feet.
    1. Install the jacks and cables in the same manner as those for positions #1 and #2.
    2. Punch down the voice/data cables to block #2 as listed in Table 10.
    3. Punch down the power cables to the PSE-3 block as listed in Table 11.
    NOTE– The colors listed in the Console Designation columns of Table 11 show the console at position
    #3 connected to power output #1, and console at position #4 connected to power output #2.
    This is just an example; any of the three power outputs may be used (refer to Table 7).The
    PSE-3 contains three independent circuits. DO NOT connect them together – use a
    separate output for each console!
    13-102499 Rev. GPage 29
    Tone Commander 30e120 Installation Instructions 
    						
    							120 Console Cables
    Console Positions #1 and #2
    Wall
    Jack
    PinoutWall Jack
    Typical
    Wire ColorConsole #1
    Designation
    (connector 1)Console #2
    Designation
    (connector 1)Typical 3 Pair
    Console Cable
    Wire Color(actual
    wire color)
    1 WHT 1C+ (YEL-BRN) 2C+ (VIO-GRN) WHT-GRN
    2 BLK 1C+ (YEL-GRN) 2C+ (VIO-ORN) WHT-ORN
    3 RED 1C- (ORN-YEL) 2C- (BLU-VIO) BLU-WHT
    4 GRN 1C+ (YEL-ORN) 2C+ (VIO-BLU) WHT-BLU
    5 YEL 1C- (GRN-YEL) 2C- (ORN-VIO) ORN-WHT
    6 BLU 1C- (BRN-YEL) 2C- (GRN-VIO) GRN-WHT
    Table 12–120 Console “Power” Jack Pinout, Console Positions #1 and #2
    The power cables from consoles #1 and #2 connect to 120 block #1. The total length of each console
    cable, including line cord and equipment room cross connects, must not exceed 500 feet.
    Page 3013-102499 Rev. G
    Tone Commander 30e120 Installation Instructions
    Figure 9 
    						
    All Tone Commander manuals Comments (0)