Home
>
Steinberg
>
Music Production System
>
Steinberg Cubase SX/SL 3 MIDI Devices And Features Manual
Steinberg Cubase SX/SL 3 MIDI Devices And Features Manual
Have a look at the manual Steinberg Cubase SX/SL 3 MIDI Devices And Features Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 523 Steinberg manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
CUBASE SX/SLMIDI devices 1 – 61 •All the values that have been defined now appear in the Add Parame- ters dialog and can be assigned to a so called “Formula”. 22.Click in the Formula column for the DevID and enter “DevID”, to set this value to a variable called “DevID”. As there is no “DevID” variable defined yet, you get “error” as a result. For now, this can be ignored. We will define the “DevID” variable later. 23.Now you need to set the right address. In the Scale Tune table of the manual, “Address1MSB” and “Address2” are set to 0 for all parame- ters of the “Scale Tune” nodes. Therefore, leave them as they are: al- ready set to 0. “Address3” indicates the part which is affected by each Scale Tune and ranges from 10H to 20H. Remember: you created the 17 Scale Tune nodes by using a variable called “Part” which ranged from 1-17, so if you add 15 to this “Part” variable, you get the desired range of 10H-20H, which is 16-32 in decimal. To achieve this, simply type in “Part+15” in the “Formula” column for “Address3”. (You can also use other operations in the “Formula” column: “-” (subtraction), “*” (multi- plication) and “()” (parentheses) for small calculations.) 24.Finally, enter “index” in the Formula column for “Address4LSB” be- cause this variable will be used to create multiple (12) parameters at once, as set in the “Variable” section of the “Add Parameters” dialog. Again, “error” is displayed in the Result field, because there is no such variable defined yet. In fact “index” is no real variable, because it sim- ply will be replaced by each of the values in the defined range after completion of the dialog.
CUBASE SX/SL1 – 62 MIDI devices The dialog should now be set up as follows: As you may have noticed, the variable “x” is automatically assigned to the “Data” value. “x” stands for the value that is represented by this parameter and is always defined individually by each parameter. If you later assign a control like a fader to this parameter, this fader will con- trol and modify “x”. “x” is automatically assigned to the last value of the message, but can be freely assigned to any other value. 25.Click OK to close the dialog. In the device editor, small plus symbols are now displayed next to the Scale Tune nodes, indicating further content. Before looking into these nodes, you should add the missing “DevID” variable to the root of the device, because this is a global value that affects the device as a whole. 26.Select the “Roland JV-1080” node, click the “Add Variable” button and rename it to “DevID”. Normally, you can keep the default value setting of “0”, except if your hardware device is set to another value.
CUBASE SX/SLMIDI devices 1 – 63 27.Now, let’s look into the Scale Tune 1 node by clicking its plus symbol. You can now browse the parameters, to verify that the correct MIDI messages are transmitted. You can of course also do this for any of the other nodes. 28.The next step is to rename the parameters according to the “Scale Tune” table of the device’s manual by selecting each of the 12 param- eters and entering their correct name in the “Name” field. Now, the parameters should be displayed as follows: …to display the parameters for the node. Click here…
CUBASE SX/SL1 – 64 MIDI devices •If you open any of the other Scale Tune nodes now, you’ll see that the names of the parameters have also changed. This is what was meant by “alias copies” in the beginning. Furthermore, you will notice that if you add a panel to one of the Scale Tune nodes (see page 20), it will be added to all of them, which makes it much easier to create panels with repeating sections. 29.Now, you need to add parameters to another node, “System Common”. In the list to the left, select “System Common”. 30.Click the Add Parameters button and select the Sysex message “Roland JV-1080 DataSet1 7 Bit” you created earlier. 31.Now set set up the DevID as described before. See page 61.
CUBASE SX/SLMIDI devices 1 – 65 32.Activate the Create Multiple checkbox and enter a range of 0-81, be- cause the System Common table in the manual of the JV-1080 con- tains 82 parameters, starting with an index of “0”. Address1MSB, Address2 and Address 3 are all 0 for all System Common parameters, so leave them as they are. Enter “index” in the Formula column for Address4LSB to ad- dress each of the 82 parameters separately. The dialog should now look like this:
CUBASE SX/SL1 – 66 MIDI devices When you click OK, you will notice that 82 new parameters have been added to the System Common node. You can now set the Names, Min, Max and Default values for each of the parameters according to the specifications in the System Com- mon table, as described earlier. You should now be familiar enough with the basic procedures to con- tinue with other parameter settings and adjustments and to finally cre- ate your own specific devices.
CUBASE SX/SLMIDI devices 1 – 67 About Studio Connections (Cubase SX only) Studio Connections is the name of an initiative led by Steinberg and Yamaha. The initiative intends to create industry standards for totally in- tegrated system environments using software and hardware products. First implementation stage of the Studio Connections open standard is the integration and support of Yamaha’s Studio Manager 2 and Total Recall for compatible hardware devices.
CUBASE SX/SL1 – 68 MIDI devices If you have a SM2 component installed, there is an additional menu item in the Devices menu for the Yamaha Studio Manager window. Total Recall Total Recall means that you can save and recall all settings of your hardware and software products by opening one integrated file in a DAW such as Cubase or Nuendo. Also you will have instant and or- ganized access to hardware editors. When you load a project or switch to another active project that con- tains SM2 data, the Total Recall Synchronization dialog appears: This dialog can also be opened any time from the Studio Manager’s Synchronize menu. Click OK for the Dump to start.
CUBASE SX/SLMIDI devices 1 – 69 Virtual MIDI Devices If you have a new OPT component (e. g. the DM2000) which uses a new special interface, you can access these components as virtual MIDI Devices in the MIDI track’s out port selection. When a MIDI Track is routed to such a device, the “Panel” Button becomes available. Click the Panel button… …to open the editor window for the device. •Please also refer to the separate Yamaha documentation.