Page 471
Programming LCR TablesB-11 Appendix B - Least Cost Routing 2. Enter the table information as follows: T T = Insert/Delete Table Number 00–19 X = [0] Pre-Delete numbers (first digits dialed in the number), -or- [1] Pre-Insert numbers (insert digits in front of number dialed, -or- [2] Post-Insert numbers (insert digits behind number dialed). DDD = Digits (up to 16-digits may be deleted from the beginning of the number dialed and up to 40 digits can be inserted (20 pre and 20 post). 3. Press the HOLD...
Page 472
B-12Programming LCR Tables Appendix B - Least Cost Routing Entries in the Daily Start Time table are used to select the time period to reference in the weekly schedule. Based on the time a call is placed, the daily start time table selects the time period to choose in the weekly schedule. The weekly schedule is then used to determine the time period route list in the Route List Table to use for routing the call for a particular day of the week. Times are entered in the 24-hour format. Figure B-2:...
Page 473
Programming LCR TablesB-13 Appendix B - Least Cost Routing EXAMPLE -- If a call is placed at 5:45 pm on a Monday, then according to the Daily Start Time Table (using default values) the entry for time period two of the weekly schedule is checked. Because it is Monday the entry for time period two on Monday is used and the result is that the Time Period Route List number two (again using default values) is used for all routes. Thus, the call is routed according to the entries in Time Period Two Route...
Page 474
B-14Programming LCR Tables Appendix B - Least Cost Routing LCR Routing for Toll Information Description The LCR Routing for Toll Information feature adds provisions to the LCR call processing which allows common call routing for all toll information calls. 1-(XXX) 555-1212, (XXX) 555-1212, 1-555-1212, and 555-1212 calls are intercepted and sent to a selected route in the Route List Table. Numbers dialed are integrated and if it is determined to be a toll information call, either preceded with an area...
Page 475
Programming LCR TablesB-15 Appendix B - Least Cost Routing 3. Press HOLD to save the entry. A confirmation tone sounds. DEFAULT … LCR Call Progress feature is enabled. Default LCR Database Description In an effort to decrease installation and set up time usually associated with LCR, a default LCR database was incorporated. The default LCR database provides basic routing for local and long distance dialing. Default entries have been made in the 3-Digit Table for local office codes (NNXs) and all area...
Page 476
B-16Programming LCR Tables Appendix B - Least Cost Routing 3. Press HOLD to save the entry. A confirmation tone sounds and the display updates. Flexible button #19 is lit. The display updates to reflect current programming for Page A: 4. Press the FORCE LCR flexible button (Button #11). The following message displays: 5. Enter a 0 or 1 on the dial pad to enable/disable this feature. [0] = Disabled [1] = Enabled 6. Press HOLD to save the entry. A confirmation tone sounds. Conditions » Only one station at...
Page 477
Programming LCR TablesB-17 Appendix B - Least Cost Routing Programming Steps 1. Press FLASH and dial [50] or dial [51]. Flexible button #24 (New Range) is lit and one of the following messages displays: 2. Enter the range of fixed station numbers (100-351) to be programmed. If only one station is being programmed, enter that number twice, e.g., [100 100]. -or- Enter a valid flexible number (100-8999) to be programmed. 3. Press HOLD to save the entry. A confirmation tone sounds and the display updates....
Page 478
B-18Programming LCR Tables Appendix B - Least Cost Routing Conditions » Only one station at a time can be programmed when using a flexible station number. » When in Flash 51 programming, if you press HOLD without specifying a flexible number to be programmed, you will get the station that is in port/station 100. Enable / Disable Least Cost Routing Description To use Least Cost Routing, it must be enabled. Before enabling LCR, refer to the Least Cost Routing programming tables. After the tables are...
Page 479
Programming LCR TablesB-19 Appendix B - Least Cost Routing Programming Steps 1. Press the CALL COST DISPLAY flexible button (FLASH 05, Button #11). 2. Enter a 0 or 1 that corresponds with the following entries: [0] = Disabled [1] = Enabled 3. Press HOLD to save the entry. A confirmation tone sounds. DEFAULT … Call Cost Display is disabled. Conditions » The user must have LCR enabled to get the Call Cost Display. Initialize LCR Tables Description The LCR Tables may be initialized to set all tables to...
Page 480
B-20Programming LCR Tables Appendix B - Least Cost Routing Programming Steps 1. Press the LCR TABLES flexible button (FLASH 80, Button #7). The following message displays: 2. Press the HOLD button. A confirmation tone sounds. Print LCR Tables Description The Print LCR Tables command dumps the entire database as a permanent record which can serve as a hardcopy of the database. The system baud rate must match that of the printer or receiving device. When printing information from the LCR Tables, the...