MX-B200 SIMULATION, TROUBLE CODES 10 - 14 46 18 Image contrast adjustment (300dpi)[Function] Contrast is set for each mode. When this simulation is executed, the current set value is displayed in 2 digits (Default: 50). Change the set value and press [START] key to make a copy under the set value. When the set value is increased, the contrast becomes higher. When the set value is decreased, the contrast becomes lower. In this case, only Exp.3 copy is made. When, however, the setting is made to make higher con- trast, Exp.1 and Exp.5 copies also become in higher contrast. When made to a lower contrast, Exp1. and Exp.5 copies become lower contrast, too. Press [Exposure mode selector] key to switch the mode. The set value of the selected mode is displayed on the LED/display. (Adjustment value: 1 – 99) [Operation] The operation is similar to simulation 46-01. 19 Exposure mode setup (AE mode)[Function] < γ table setting> When this simulation is executed, the code number of the current set gamma table is displayed. (Default: 2) Enter the code number corresponding to the desired gamma table, and press [Exposure mode selector] key to change the mode and write into the EEPROM. When setting the γ table, press [Exposure mode selector] key to change to the AE operation mode, and the current set code number of the AE operation mode is displayed. (Default: 0) Enter the code number corresponding to the desired AE operation mode and press [Exposure mode selector] key to change the mode and write into the EEPROM. When [Exposure mode selector] key is pressed in AE operation mode setting, the mode is changed to the PHOTO image process setting and the code number of the current set PHOTO image process setting is displayed. (Default: 1) Enter the code number corresponding to the desired PHOTO image process setting and press [Exposure mode selector] key to change the mode and write into the EEPROM. [Operation] The operation is similar to simulation 46-01. Main codeSub codeContents Details of function/operation Mode Display lamp Default AE mode (300dpi) AE mode lamp 50 TEXT mode (300dpi) TEXT mode lamp 50 PHOTO mode PHOTO mode lamp 50 TS mode (TEXT) (300dpi) TEXT mode lamp PHOTO mode lamp50 TS mode (AE) (300dpi) AE mode lamp PHOTO mode lamp50 Dither mode AE mode lamp TEXT mode lamp PHOTO mode lamp50 Mode Display lampCode numb erSetting contentRemar k γ OFF1 Image quality priority mode 2Toner consumption priority modeDefault AE AE 0 Lead edge stop Default 1 Real time process PHOT OPHOTO1 Error diffusion process Default 2 Dither process
![](/img/blank.gif)
MX-B200 SIMULATION, TROUBLE CODES 10 - 15 46 20 SPF exposure correction (Option)[Function] Used to adjust the exposure correction amount in the SPF mode. The adjustment is made by adjusting Vref voltage variation for the OC mode. When this simulation is executed, the current set value is displayed in 2 digits (Default: 50). Change the set value and press [START] key to save the setting and make a copy. When the set value is increased, copy becomes darker. When the set value is decreased, copy becomes lighter. (Adjustment range: 1 – 99) [Operation] The operation is similar to simulation 46-01. 29 Image contrast adjustment (600dpi)[Function] Contrast is set for each mode. When this simulation is executed, the current set value is displayed in 2 digits (Default: 50). Change the set value and press [START] key to make a copy under the set value. When the set value is increased, the contrast becomes higher. When the set value is decreased, the contrast becomes lower. In this case, only Exp.3 copy is made. When, however, the setting is made to make higher con- trast, Exp.1 and Exp.5 copies also become in higher contrast. When made to a lower contrast, Exp1. and Exp.5 copies become lower contrast, too. Press [Exposure mode selector] key to switch the mode. The set value of the selected mode is displayed on the LED/display. (Adjustment value: 1 – 99) [Operation] The operation is similar to simulation 46-01. 30 AE limit adjustment[Function] Used to set the limit value in AE and AE (toner save). Change the setting and press [START] key to write the setting into the EEPROM. The machine goes into the sub code entry standby mode. By pressing [Exposure mode selector] key, setting is changed. (Setting range: 0 – 255, Default: 196) When simulation 26-06 (Destination setting) or simulation 46-19 Auto Exposure mode is changed, the setting of this simulation is also changed to the default in connection. [Operation] The operation is similar to simulation 46-19. Main codeSub codeContents Details of function/operation Mode Display item Display lamp Default Remark SPF SPF TEXT mode lamp 50 Mode Display lamp Default AE mode (600dpi) AE mode lamp 50 TEXT mode (600dpi) TEXT mode lamp 50 PHOTO mode PHOTO mode lamp 50 TS mode (TEXT) (600dpi) TEXT mode lamp PHOTO mode lamp50 TS mode (AE) (600dpi) AE mode lamp PHOTO mode lamp50 Dither mode AE mode lamp TEXT mode lamp PHOTO mode lamp50 Mode Display lamp Remark Limit value for AE (OC) AE mode lamp Limit value for AE (OC) (toner save)TEXT mode lamp Limit value for AE (SPF) AE mode lamp PHOTO mode lamp Limit value for AE (SPF) (toner save)TEXT mode lamp PHOTO mode lamp
![](/img/blank.gif)
MX-B200 SIMULATION, TROUBLE CODES 10 - 16 46 31 Image sharpness adjustment[Function] Used to adjust sharpening/blurring of image in each mode. When this simulation is executed, warm-up and shading are performed and the current set value is displayed. (Default: 1) Change the set value and press [START] key to make a copy under the set conditions. To change the mode, press [Exposure mode selector] key. The code number of the selected mode is diplayed on the LED/display. [Operation] The operation is similar to simulation 46-01. 32 Copier color reproduction setup[Function] Used to set color reproduction in each mode. Colors easy to be copied and colors difficult to be copied can be switched. * This setting has virtually no effect on black-and-white documents. When this simulation is executed, warm-up and shading are performed and the current set value is displayed. (Default: 0) Press [START] key to make a copy under the set conditions . At that time, color components are changed for used in copying. To change the mode, press [Exposure mode selector] key. The code number of the selected mode is displayed on the LED/display. [Operation] The operation is similar to simulation 46-01. Main codeSub codeContents Details of function/operation Image quality Setting No Remark Blurring 0 Standard 1 Default Sharpening 2 Mode Display lamp Default AE mode AE mode lamp 1 TEXT mode TEXT mode lamp 1 PHOTO mode PHOTO mode lamp 1 TS mode (TEXT) TEXT mode lamp PHOTO mode lamp1 TS mode (AE) AE mode lamp PHOTO mode lamp1 Dither mode AE mode lamp TEXT mode lamp PHOTO mode lamp1 Set value Colors easy to be copied Colors difficult to be copied 0 Purple, Blue, Red Yellow, Green, Water blue 1 Water blue, Green, Blue Purple, Red, Yellow 2 Yellow, Red, Green Blue, Water blue, Purple Specification component Setting No Remark Green 0 Default Red 1 Blue 2 Mode Display lamp Default AE mode (including TS) AE mode lamp 0 TEXT mode (including TS) TEXT mode lamp 0 PHOTO mode PHOTO mode lamp 0
![](/img/blank.gif)
MX-B200 SIMULATION, TROUBLE CODES 10 - 17 48 01 Front/rear (main scanning) direction and scan (sub scanning) direction magnification ratio adjustment[Function] Used to adjust the magnification ratio in the main scan (front/rear) direction and sub scan direc- tion. Enter the adjustment value with [ ] [ ] key. Press [START] key to save the set value and make a copy. (When the adjustment value is increased by 1, the magnification ratio is increased by 0.1%.) The adjustment mode can be changed by pressing [Exposure mode selector] key. (Adjustment range: 1 – 99, Default: 50) [Operation] The operation is similar to simulation 46-01. 05 SPF mode sub scan direction magnification ratio in copying (Option)[Function] Used to display the current SPF mode sub scan direction magnification ratio on the LED/dis- play. When [START] key is pressed, the entered data is acquired and saved into the EEPROM, and a copy is made. (When the set value is increased by 1, the magnification ratio is increased by 0.1%.) The adjustment mode can be changed by pressing [Exposure mode selector] key. (Adjustment range: 1 – 99, Default: 50) For printing, regardless of the density mode and the density level, Density mode = TEXT Density level = 3 * When there is no document in SPF, copy is inhibited. [Operation] The operation is similar to simulation 46-01. 49 01 Flash ROM program writing mode[Function] When this simulation is executed, d is displayed on the display, the machine goes into the pro- gram writing mode from PC to Flash ROM. Use the writing tool on the PC and write the program. During writing, the display shows as follows: After completion of download, turn OFF/ON the power to reset. To enter the download mode, there is a method to use key operations as well as to use a simu- lation. With the power OFF, press and hold [Exposure mode select] key + [ZOOM DOWN] key, turn on the power. Main codeSub codeContents Details of function/operation Mode Display lamp Default Main scan direction magnification ratioTEXT mode lamp 50 OC mode sub scan direction magnification ratioPHOTO mode lamp 50 Mode Display lamp Default Sub scan magnification ratio adjustment on the front surface of SPF documentAE mode lamp 50 * ∗ in an error display indicates the error position.Status DisplayPre- heat lampReady lampRemark Download data receiving d ON ON OFF Date delete start d ON OFF ON Data write (Boot section) d ON Blink OFF Data write (Program section)d ON Blink Blink During SUM CHECK d ON ON ON Download complete 0FF ONOFF OFF Error state E ∗ ONOFF OFF 1 Data reception error 6 Sum check (Loader section) 2 Loader function transfer 7 Sum check (Boot section) 3 FLASH ROM delete 8 Sum check (Program section) 4 FLASH ROM writing (Boot section)9 Sum check (EEPROM section) 5 FLASH ROM writing (Program section)10 Data error
![](/img/blank.gif)
MX-B200 SIMULATION, TROUBLE CODES 10 - 18 50 01 Lead edge image position[Function] Used to adjust the copy image position and the lead edge void amount on copy paper. The adjustment is made by adjusting the image scan start position at 100% and the print start posi- tion (resist roller ON timing). When this simulation is executed, the current set value is dis- played in 2 digits. (Center value: 50) When [Exposure mode selector] key is pressed, the setting mode and the display are changed. Enter the adjustment value and press [START] key to save the set value and make a copy. When the adjustment is made by the main cassette paper feed, the adjustment values of all the paper feed ports become the same. (When the set value is increased by 1, shift is made by 0.1mm.) * When printing with the manual paper feed tray, use paper of the letter size. [Adjustment procedure] 1) Set the print start position (AE lamp ON) (A), the lead edge void amount (TEXT lamp ON) (B), and the scan start position (PHOTO lamp ON) (C) to 0, and make a copy of a scale at 100%. 2) Measure the image loss (Rmm) of the scale. Set C = 10 x R (mm). (Example: Set to 40.) When the value of C is increased by 10, the image loss is decreased by 1mm. (Default: 50) 3) Measure the distance (Hmm) from the paper lead edge to the image print start position. Set A = 10 x H (mm). (Example: Set to 50.) When the value of A is increased by 10, the image lead edge is moved to the paper lead edge by 1mm. (Default: 50). 4) Set the lead edge void amount to B = 50 (2.5mm). (Default: 50) When the value of B is increased by 10, the void is extended by about 0.1mm. (For 25 or less, however, the void amount is regarded as 0.) ∗The SPF adjustment is made by adjusting the SPF image scan start position after OC adjustment. [Operation] The operation is similar to simulation 46- 01. Main codeSub codeContents Details of function/operation Mode Display lamp Default Print start position (Main cassette paper feed)AE mode lamp Main cassette lamp50 Print start position (2nd cassette paper feed)AE mode lamp 2nd cassette lamp50 Print start position (Manual paper feed)AE mode lamp Manual feed lamp50 Image lead edge void amountTEXT mode lamp Main cassette lamp50 Image scan start position PHOTO mode lamp Main cassette lamp50 Image rear edge void amount (Cassette paper feed)AE mode lamp TEXT mode lamp PHOTO mode lamp Main cassette lamp50 Image rear edge void tAE mode lamp TEXT d l50 5mm 10mm Distance from the paper lead edge to the image lead edge, H = 5mm Image loss, R = 4mm (Example)
![](/img/blank.gif)
MX-B200 SIMULATION, TROUBLE CODES 10 - 19 50 06 Copy lead edge position adjustment (SPF) (Option)[Function] Used to adjust the SPF copy lead edge. When the adjustment value of the document scan position adjustment is increased by 1, the scan start timing is advanced by 0.1mm. The print result is shifted to the opposite direction of the scan start position. The adjustment mode can be changed by pressing [Exposure mode selector] key. (Adjustment range: 1 – 99, Default: 50) ∗When there is no document in the SPF, copy is inhibited. [Operation] The operation is similar to simulation 46-01. 10 Center offset adjustment[Function] Used to adjust the center offset position of copy images on copy paper and that in scanning document. When this simulation is executed, the current set value is displayed. Enter the adjustment value and press [START] key to save the setting and make a copy. (When the set value is changed by 1, the center is shifted by 0.1mm.) When the adjustment value is increased, the center is shifted to right. When decreased, the center is shifted to left. The modes can be selected by pressing [Exposure mode selector] key. When the set value is changed largely, the area outside the shading area may be scanned to cause black streaks on the edges. * When printing with the manual paper feed tray, use paper of the letter size. * In the 2nd print center offset adjustment, print is made forcibly as 1to2/Short Edge from OC regardless of duplex setting. [Operation] The operation is similar to simulation 46-01. 12 Document off-center adjustment[Function] Used to adjust document scan off-center adjustment. The adjustment modes can be selected by pressing [Exposure mode selector] key. (Adjustment range: 1 – 99, Default: 50) When the adjustment value is increased, the print result is shifted to left. [Operation] The operation is similar to simulation 46-01. Main codeSub codeContents Details of function/operation Mode Display lamp Default Front surface document scan position adjustmentAE mode lamp 50 Rear edge void adjustment (SPF)PHOTO mode lamp 50 Mode Display lamp Default Print center offset (Main cassette paper feed)AE mode lamp Main cassette lamp50 Print center offset (2nd cassette paper feed)AE mode lamp 2nd cassette lamp50 Print center offset (Manual paper feed)AE mode lamp Manual paper feed lamp50 Mode Display lamp Default Platen document scan AE mode lamp 50 SPF document front scan TEXT mode lamp 50
![](/img/blank.gif)
MX-B200 SIMULATION, TROUBLE CODES 10 - 20 51 02 Resist quantity adjustment[Function] Used to adjust the contact pressure of the main unit resist roller and the SPF resist roller onto paper. When this simulation is executed, the current set value is displayed. The adjustment modes can be selected by pressing [Exposure mode selector] key. Enter the adjustment value with [ ] [ ] key and press [START] key to save the set value and make a copy. [Operation] The operation is similar to simulation 46-01. 53 08 SPF scan position automatic adjustment (Option)[Function] Place a A4 paper (white chart) so that it covers the SPF scan glass and the OC glass together, and close the SPF. When this simulation is executed, the current adjustment value is displayed as the initial display. * Default is 50. Adjustment range is 1 – 99. Adjustment unit 1 = about 0.127mm In case of AUTO, press [START] key, and the mirror unit scans from the home position to the SPF scan position with the adjustment value displayed. The SPF glass cover edge position is calculated from the difference between the SPF glass cover edge and the OC side document glass CCD output level. If the adjustment is normal, the adjusted value is displayed. If abnor- mal, the JAM LED lights up with the current set value displayed. During the JAM LED is lighted, when [START] key is pressed again, execution is performed again. [Operation] The operation is similar to simulation 46-01. (In MANUAL) 61 03 Polygon motor check (HSYNC output check)[Function] When [START] key is pressed, HSYNC is performed and the polygon motor is rotated for 30sec. At that time, the ZOOM lamp is lighted for 100msec every time when HSYNC is detected. The sub code display is lighted. (After completion of execution, it blinks.) 63 01 Shading check[Function] Used to display the detection level of white plate for shading. When [START] key is pressed, the mirror base unit moves to the white plate for shading and the copy lamp is lighted. When the light quantity is stabilized, revision is made for every second, and the level of one pixel at the center of CCD which is not corrected is detected and the value is displayed in deci- mal values on the LED. Main codeSub codeContents Details of function/operation Mode Display lamp Default Main cassette paper feed AE mode lamp Main cassette lamp50 2nd cassette paper feed AE mode lamp 2nd cassette lamp50 Manual paper feed AE mode lamp Manual paper feed lamp50 Mode Display lamp Default SPF scan position auto adjustmentAE mode lamp 50 SPF scan position manual adjustmentTEXT mode lamp 50
![](/img/blank.gif)
MX-B200 SIMULATION, TROUBLE CODES 10 - 21 63 02 Black level automatic correction[Function] Used to acquire the black level target value used for the black level adjustment of white balance. When this simulation is executed, the current correction value is displayed in 3 digits of 12bit hexadecimal number. Place the gray gradation chart (UKOG-0162FCZZ) used as the correction document so that the density 10 (black side) comes on the left side and that the chart is upside down at the center of the plate left center. When [START] key is pressed, the mirror base unit scans the chart and calculates the correc- tion value. After completion of correction, the corrected value is displayed on the LED/display. ∗Default: 0 ∗If the value is set to the default, operation is made with 0x60. ∗Incase of an error, the JAM lamp lights up. ∗If C key is pressed during canceling, the machine goes into the sub code entry standby mode after canceling. 12 Light quantity stabilization wait time setting[Function] Used to set the wait time before entering the light quantity level stable evaluation process in the light quantity stable process of white balance. (Note: The light quantity stable level in the previ- ous light quantity stable state is used as the target. When the light quantity level reaches the target during the wait time, the set time of this simulation is ignored and the operation enters the stable evaluation process.) When this simulation is executed, the currently set value is displayed. Enter the adjustment value with [ ] [ ] key and press [START] key. The entered value is stored and the machine goes into the sub code entry standby mode. Setting range: 0 – 99 (Complying with the light quantity stable wait time of 0 – 99sec.) Default: 15 (15sec) [Operation] The operation is similar to simulation 9-04. 13 Light quantity stabilization band setting[Function] When the difference between the maximum and the minimum values of the light quantity level sampled for 3.2sec in the cycle of 100msec in the white balance light quantity stable process is within the range set with this simulation, it is judged as the light quantity is stable. (Note: The magnification ratio of the AFE gain setting is automatically reflected on the stable width.) When this simulation is executed, the currently set value is displayed. Enter the adjustment value with [ ] [ ] key and press [START] key. The entered value is stored and the machine goes into the sub code entry standby mode. Setting range: 1 – 99 (Light quantity stable width: Complying with 1 – 99 in 4095 gradations.) Default: 16 [Operation] The operation is similar to simulation 9-04. Main codeSub codeContents Details of function/operation Chart back surface 10
![](/img/blank.gif)
MX-B200 SIMULATION, TROUBLE CODES 10 - 22 5. Trouble codes A. Trouble codes list B. Details of trouble codes 64 01 Self print[Function] The status of the optical section is ignored and printing of one page is made. Also when the print command is received from the host, printing is made. When this simulation is executed, warm-up is performed and the ready lamp is lighted. (Since, however, the scanner is disabled, initializing is not made.) Enter the code number and press [START] key to start paper feed from the selected cassette and print in the selected pattern. * For 4 – 99, flip. [Operation] The operation is similar to simulation 26-02. Main codeSub codeContents Details of function/operation Code number Pattern Display item 01by21 BY 2 1 Grid pattern CHECK 2 White paper WHITE 3 Black background BLACK Mai n codeSub codeDetails of trouble E7 01 Image data error 06 Image data decode error 10 Shading trouble (Black correction) 11 Shading trouble (White correction) 16 Abnormal laser output 20 LSU trouble F2 64 Toner supply abnormality 70 Improper cartridge 74 Toner cartridge CRUM error F5 02 Copy lamp lighting abnormality H2 00 Thermistor open H3 00 Heat roller high temperature detection H4 00 Heat roller low temperature detection L1 00 Feeding is not completed within the specified time after starting feeding. L3 00 Scanner return trouble L4 01 Main motor lock detection 31 Exhaust fan motor lock detection trouble L6 10 Polygon motor lock detection U2 00 EEPROM read/write error (Serial communication error) 11 Counter check sum error (EEPROM)Main codeSub codeDetails of trouble E7 01 ContentImage data error Detail Communication error with the E-sort module MCU PWB trouble ASIC trouble Check and remedyCheck if it occurs again when the power is turned OFF and ON. If so, replace the PWB. 06 ContentImage data decode error Detail Image expansion error Cause MCU PWB abnormality USB cable trouble Check and remedyReplace the MCU PWB. Replace the USB cable. 10 ContentShading trouble (Black correction) Detail The CCD black scan level is abnormal when the shading. Cause Improper connection of the CCD unit flat cable CCD unit abnormality MCU PWB abnormality Check and remedyCheck connection of the CCD unit flat cable. Check the CCD unit. 11 ContentShading trouble (White correction) Detail The CCD white scan level is abnormal when the shading. Cause Improper connection of the CCD unit flat cable Dirt on the mirror, the lens, and the reference white plate Copy lamp lighting abnormality CCD unit abnormality MCU PWB abnormality (When occurred in the SPF scan position.) Improper installation of the mirror unit Check and remedyClean the mirror, lens, and the reference white plate. Check the light quantity and lighting status of the copy lamp (SIM 05-03). Check the MCU PWB.
![](/img/blank.gif)
MX-B200 SIMULATION, TROUBLE CODES 10 - 23 E7 16 ContentAbnormal laser output Detail When the laser output is stopped, HSYNC is detected. Cause Laser abnormality MCU PWB abnormality. Check and remedyCheck the laser emitting diode operation. Replace the MCU PWB. 20 ContentLSU trouble Detail The BD signal from the LSU cannot be detected in a certain cycle. (Always OFF or always ON) Cause LSU connector or LSU harness defect or disconnection Polygon motor rotation abnormality Laser beams are not generated. MCU PWB abnormality. Check and remedyCheck connection of the LSU connector. Execute SIM 61-03 to check the LSU operations. Check that the polygon motor rotates normally. Check that the laser emitting diode generates laser beams. Replace the LSU unit. Replace the MCU PWB. F2 64 ContentToner supply abnormality Detail The maximum toner supply time is greatly exceeded. Cause CRUM chip trouble Improper developing unit Check and remedyReplace the CRUM chip. Replace the developing unit. 70 ContentImproper cartridge Detail The destination of the main unit differs from that of the CRUM. When the life cycle information is other than Not Used (FFh). Cause CRUM chip trouble Improper developing unit Check and remedyReplace the CRUM chip. Replace the developing unit. 74 ContentToner cartridge CRUM error Detail MCU Cause Toner cartridge (CRUM) trouble. MCU PWB trouble. Connector/harness trouble. Check and remedyReplace the toner cartridge. Replace the MCU PWB. Connector and harness check. Main codeSub codeDetails of trouble F5 02ContentCopy lamp lighting abnormality Detail The copy lamp does not turn on. Cause Copy lamp abnormality Copy lamp harness abnormality CCD PWB harness abnormality. Check and remedyUse SIM 5-3 to check the copy lamp operations. When the copy lamp lights up. Check the harness and the connector between the CCD unit and the MCU PWB. When the copy lamp does not light up. Check the harness and the connector between the copy lamp unit and the MCU PWB. Replace the copy lamp unit. Replace the MCU PWB. H2 00 ContentThermistor open Detail The thermistor is open. The fusing unit is not installed. Cause Thermistor abnormality Control PWB abnormality Fusing section connector disconnection The fusing unit is not installed. Check and remedyCheck the harness and the connector between the thermistor and the PWB. Use SIM 14 to clear the self diagnostic display. H3 00 ContentHeat roller high temperature detection Detail The fusing temperature exceeds 240°C. Cause Thermistor abnormality Control PWB abnormality Fusing section connector disconnection. Check and remedyUse SIM 5-02 to check the heater lamp blinking operation. When the lamp blinks normally. Check the thermistor and its harness. Check the thermistor input circuit on the control PWB. When the lamp keeps ON. Check the power PWB and the lamp control circuit on the MCU PWB. Use SIM 14 to clear the self diagnostic display. Main codeSub codeDetails of trouble