    							MX-B200  SIMULATION, TROUBLE CODES  10 - 4 8 01 Developing bias[Function]
    When [START] key is pressed, the developing bias signal is turned ON for 30sec.
    When, however, an actual output value is measured, use simulation 25-01.
    After completion of this process, the machine goes into the sub code entry standby mode.
    02 Main charger (Grid high)[Function]
    When [START] key is pressed, the main charger is outputted for 30sec in the grid voltage HIGH
    move.
    After completion of this process, the machine goes into the sub code entry standby mode. 
    03 Grid voltage (Low)[Function]
    When [START] key is pressed, the main charger is outputted for 30sec in the grid voltage LOW
    move.
    After completion of this process, the machine goes into the sub code entry standby mode.
    06 Transfer charger[Function]
    When [START] key is pressed, the transfer charger is outputted for 30sec.
    After completion of this process, the machine goes into the sub code entry standby mode.
    10 Toner motor aging[Function]
    When [START] key is pressed, the toner motor is rotated for 30sec.
    After completion of this process, the machine goes into the main code entry standby mode.
    14 Cancel of troubles other than 
    U2[Function]
    Used to cancel troubles other than U2.
    ∗Cancel troubles such as H trouble which writes data into EEPROM, and perform hardware 
    reset.
    16 Cancel of U2 trouble[Function]
    Used to cancel U2 trouble.
    When [START] key is pressed, check sum of the total counter in the EEPROM is rewritten and
    hardware reset is made.
    20 01 Maintenance counter clear[Function]
    When [START] key is pressed, the maintenance counter value is cleared to display “000,000.”
    The upper three digits and the lower three digits of “000,000” are displayed on the 7seg display.
    21 01 Maintenance cycle setting[Function]
    The code of the currently set maintenance cycle value (default display) is displayed and the set
    data are saved.
    22 01 Maintenance counter display[Function]
    When [START] key is pressed, the maintenance counter value is displayed.
    The display method is the same as SIM20-01.
    02 Maintenance preset display[Function]
    When [START] key is pressed, the number of sheets (25,000 sheets, etc.) corresponding to the 
    code set with SIM21-01 is displayed. 
    The display method of the value is the same as SIM20-01.
    04 JAM total counter display[Function]
    The JAM total counter is displayed.
    [Operation]
    05 Total counter display[Function]
    The total counter value is displayed.
    [Operation]
    The operation is similar to simulation 22-04. Main 
    codeSub 
    codeContents Details of function/operation
    Code number Setting Remark
    0 3,000 sheets
    1 6,000 sheets
    2 9,000 sheets
    3 13,000 sheets
    4 25,000 sheets Default
    5 Free (999,999 sheets)
    The count value is displayed in 3 digits X 2 times repeatedly.
    
    01
    2 →Bla
    nk→34
    5→Bla
    nk→01
    2
    0.
    7s0.3s 0.
    7s1.0s 0.
    7s 
    						
    							MX-B200  SIMULATION, TROUBLE CODES  10 - 5 22 06 Developer counter display[Function]
    When [START] key is pressed, the developer counter data are acquired and displayed. 
    The display method of the value is the same as SIM20-01.
    08 SPF counter display (Option)[Function]
    The SPF counter is displayed.
    [Operation]
    The operation is similar to simulation 22-04.
    12 Drum counter display[Function]
    The drum counter is displayed.
    [Operation]
    The operation is similar to simulation 22-04.
    13 CRUM type display[Function]
    When [START] key is pressed, the CRUM type which is currently set (written) in the CRUM chip 
    is displayed.
    14 ROM version display[Function]
    The P-ROM version is displayed.
    [Operation]
    The operation is similar to simulation 22-04.
    17 Copy counter display[Function]
    The copy counter is displayed.
    [Operation]
    The operation is similar to simulation 22-04.
    18 Printer counter display[Function]
    The printer counter is displayed.
    [Operation]
    The operation is similar to simulation 22-04.
    19 Scanner mode counter 
    display[Function]
    The scanner mode counter is displayed.
    [Operation]
    The operation is similar to simulation 22-16.
    21 Scanner counter display[Function]
    The scanner counter is displayed.
    [Operation]
    The operation is similar to simulation 22-04.
    22 SPF JAM counter display 
    (Option)[Function]
    The SPF JAM counter is displayed.
    [Operation]
    The operation is similar to simulation 22-04.
    24 01 JAM total counter clear[Function]
    When [START] key is pressed, the JAM total counter is cleared to 0 and 000,000 is displayed
    on the LED/display.
    [Operation]
    The operation is similar to simulation 22-04.
    04 SPF counter clear 
    (Option)[Function]
    When [START] key is pressed, the SPF counter value is cleared to 0 and 000,000 is displayed
    on the LED/display.
    [Operation]
    The operation is similar to simulation 22-04.
    06 Developer counter clear[Function]
    When [START] key is pressed, the developer counter value is cleared to 0. 
    The display method of the value is the same as SIM20-01. Main 
    codeSub 
    codeContents Details of function/operation
    Code number CRUM type
    00 Unsetting
    01 BTA-A
    02 BTA-B
    03 BTA-C
    99 Conversion
    Code number Version
    0 Main unit Program 
    						
    							MX-B200  SIMULATION, TROUBLE CODES  10 - 6 24 07 Drum counter clear[Function]
    When [START] key is pressed, the drum counter value is cleared to 0, and 000,000 is dis-
    played on the LED/display.
    [Operation]
    The operation is similar to simulation 22-04.
    08 Copy counter clear[Function]
    When [START] key is pressed, the copy counter value is cleared to 0, and 000,000 is dis-
    played on the LED/display.
    [Operation]
    The operation is similar to simulation 22-04.
    09 Printer counter clear[Function]
    When [OK]/[START] key is pressed, the printer counter value is cleared to 0, and 000,000 is
    displayed on the LED/display.
    [Operation]
    The operation is similar to simulation 22-04.
    13 Scanner counter clear[Function]
    When [OK]/[START] key is pressed, the scanner counter value is cleared to 0, and 000,000 is 
    displayed on the LED/display.
    [Operation]
    The operation is similar to simulation 22-04.
    14 SPF JAM total counter clear 
    (Option)[Function]
    When [START] key is pressed, the SPF JAM total counter value is cleared to 0, and 000,000 is
    displayed on the LED/display.
    [Operation]
    The operation is similar to simulation 22-04.
    15 Scanner mode counter clear[Function]
    When [START] key is pressed, the scanner mode counter value is cleared to 0, and 000,000 is
    displayed on the LED/display.
    [Operation]
    The operation is similar to simulation 22-16.
    25 01 Main motor operation check 
    (Cooling fan motor rotation 
    check)[Function]
    When [START] key is pressed, the main motor is operated for 30sec.
    To reduce toner consumption, if the developing unit is installed, the developing bias, the main
    charger, and the grid are also outputted.
    In this case, laser discharge is required when stopping the motor, the polygon motor is also
    operated at the same time. Check for installation of the developing unit. If it is not installed, the
    high voltage above is not outputted and only the motor is rotated.
    To check the developing bias, install the developing unit.
    After completion of 30sec operation, the machine goes into the sub code entry standby mode.
    10 Polygon motor ON[Function]
    When [START] key is pressed, the Bios is called to rotate the polygon motor for 30sec. 
    After completion of 30sec operation, the operation is turned off with the Bios and the machine
    goes into the sub code entry standby mode.
    26 02 SPF setup (Option)[Function]
    When this simulation is executed, the current set SPF is displayed. Enter the code number cor-
    responding to the desired SPF and press [START] key to save the setting.
    03 2nd cassette setup (Option)[Function]
    When this simulation is executed, the current set 2nd cassette is displayed. Enter the code
    number corresponding to the desired 2nd cassette and press [START] key to save the setting. Main 
    codeSub 
    codeContents Details of function/operation
    Code number SPF
    0SPF NO
    1SPF YES
    Code number 2nd cassette
    0 2nd cassette NO
    1 2nd cassette YES 
    						
    							MX-B200  SIMULATION, TROUBLE CODES  10 - 7 26 06 Destination setup[Function]
    When this simulation is executed, the current set destination is displayed. Enter the code num-
    ber corresponding to the desired destination and press [OK]/[START] key to save the setting.
    * Code number 2 and 3 cannot be selected.
    [Operation]
    The operation is similar to simulation 26-02.
    07 Machine conditions check[Function]
    When this simulation is executed, the current machine setting is displayed.
    20 Rear edge void setup[Function]
    When this simulation is executed, the current set rear edge void is displayed. Enter the code
    number corresponding to the desired rear edge void and press [START] key to save the setting.
    [Operation]
    The operation is similar to simulation 26-02.
    30 CE mark support control 
    ON/OFF[Function]
    When this simulation is executed, the current set CE mark support control is displayed. Enter
    the code number corresponding to the desired CE mark support control and press [START] key
    to save the setting.
    [Operation]
    The operation is similar to simulation 26-02.
    37 Cancel of stop at developer 
    life over[Function]
    When this simulation is executed, the current setting is displayed. When the code number is 
    entered and [START] key is pressed, the setting is changed.
    39 Memory capacity check[Function]
    When the simulation is executed, the currently installed SDRAM of the main unit is displayed.
    40 Polygon motor OFF time 
    setup (Time required for 
    turning OFF after completion 
    of printing)[Function]
    When this simulation is executed, the current setting is displayed. Enter the code number corre-
    sponding to the desired setting and press [START] key to save the setting.
    [Operation]
    The operation is similar to simulation 26-02. Main 
    codeSub 
    codeContents Details of function/operation
    Code number Destination
    0 Inch series
    1 EX Japan AB series
    2 Japan AB series
    3 China
    CPM Copy quantity  Remark
    20 CPM 20
    Code number Setting Remark
    0 Rear edge void NO
    1 Rear edge void YES Default
    Code number Setting Remark
    0 CE mark support control OFF Default (100V series)
    1 CE mark support control ON
     
    Code number  Setup Remark
    0 Stop at developer life over
    1 Cancel of stop at developer life over Default
    Code number Setting Remark
    32 32 MBYTE
    Code number Setting Display item Remark
    00sec0
    1 30sec 30 Default
    2 60sec 60
    3 90sec 90 
    						
    							MX-B200  SIMULATION, TROUBLE CODES  10 - 8 26 42 Transfer ON timing control 
    setup[Function]
    Enter the code number with [UP/UP] key and press [START] key, and the entered set value is
    saved and the machine enters the sub code input standby state.
    Use [Density Select] key to select a mode. The set value of the selected mode is displayed in
    the 7seg display. Main 
    codeSub 
    codeContents Details of function/operation
    
    * The default value, 11, of the transfer ON timing indicates 236msec passed from PS
    release.
    * When set to 0, it is same as setting to the default, 11.
    * The transfer ON timing can be adjusted to 236msec ± 2ms.
    
    * The default 50 of the transfer OFF timing indicates 210msec passed from PPD1OFF.Mode LED Default Setting range
    Front surface paper 
    lead edgeAE mode lamp 11 0 - 21
    Front surface paper 
    rear edgeTEXT mode lamp 50 1 - 99
    Back surface paper 
    lead edgePHOTO mode lamp 11 0 - 21
    Back surface paper 
    rear edgeAE mode lamp
    TEXT mode lamp50 1 - 99
    Code number Setting Code number Setting
    0 Default (236 msec)  11 Default (236 msec)
    1 –20 msec  12 +2 msec
    2 –18 msec  13 +4 msec
    3 –16 msec  14 +6 msec
    4 –14 msec  15 +8 msec
    5 –12 msec  16 +10 msec
    6 –10 msec  17 +12 msec
    7 –8 msec  18 +14 msec
    8 –6 msec  19 +16 msec
    9 –4 msec  20 +18 msec
     10 –2 msec  21 +20 msec
    Code Setting Remark
    1 –98 msec
    . . . . . .
    49 –2 msec
    50 0 msec Default
    51 +2 msec
    . . . . . .
    99 +98 msec 
    						
    							MX-B200  SIMULATION, TROUBLE CODES  10 - 9 26 43 Side void setup[Function]
    When this simulation is executed, the currently set code of the side void quantity is displayed
    (initial display), and the set data are saved. (Setting range: 0 – 10, Default: 4 (= One side
    2.0mm)) 
    * When the adjustment value is increased by 1, the side void is changed as follows:
    Side void adjustment: The side void is increased by 0.5mm. (The side void of Set value x
    0.5mm is made.)
    [Operation]
    The operation is similar to simulation 09-04.
    54γ life correction setting[Function]
    Used to set the γ life correction.
    When this simulation is executed, the current set code number is displayed.
    Enter the desired code number and press [START] key to save the setting. 
    (Setting range: 0 – 1, default: 1)
    [Operation]
    The operation is similar to simulation 26-02.
    62 Energy-save mode copy 
    lamp setup[Function]
    Used to set half-ON /OFF of the copy lamp in the pre-heat mode.
    When this simulation is executed, the current set code number is displayed. Enter the desired
    code number and press [START] key to save the setting.
    [Operation]
    The operation is similar to simulation 26-02.
    69 Used to set the operating 
    conditions for toner near end[Function]
    This simulation is used to set the operating conditions for toner near end. The setting mode is 
    switched by [Density select] key. 
    The set value of the selected mode is displayed on the 7seg display.
    When the code number is entered and [START] key is pressed, the setting is switched. Main 
    codeSub 
    codeContents Details of function/operation
    Code Setting Remark
    00 mm
    10.5 mm
    21.0 mm
    31.5 mm
    4 2.0 mm Default
    52.5 mm
    63.0 mm
    73.5 mm
    84.0 mm
    94.5 mm
    10 5.0 mm
    Code number Setting Remark
    0OFF
    1 ON Default
    Code number Setting Remark
    0 Copy lamp OFF
    1 Copy lamp half-ON Default
    
    Lighting LED: AE mode lamp
    Code number Setting contents
    0 Toner near end is displayed
    1 Toner near end is not displayed
    Code number Setting contents
    1 Operation setting 1
    2 Operation setting 2
    3 Operation setting 3 
    						
    							MX-B200  SIMULATION, TROUBLE CODES  10 - 10 30 01 Paper sensor status display[Function]
    The paper sensor status is displayed on the LED.
    ∗Since the manual paper feed sensor is a single bypass sensor, its status is not displayed.
    41 06 OC cover float detection 
    level adjustment (Option)[Function]
    When this simulation is executed, the current set value is displayed. When [START] key is
    pressed, the mirror base unit moves to the SPF scan position to acquire the OC cover float
    detection level.
    When the mirror base unit returns to the home position, the acquired value is displayed.
    If the adjustment is NG, the following message is displayed.
    Misfeed lamp lights up, and the 7seg display remains unchanged.
    Note that, this simulation must be executed with the OC cover closed.
    ∗If the value is 0, float detection is not performed in normal jobs.
    07 OC cover float detection 
    margin setting (Option)[Function]
    For the number of pixels between black markers on the SPF scanning position saved in 41-06:
    (OC cover float detection level adjustment), if the number of pixels between the markers when
    processing float detection is less than the number of pixels set with this simulation, it is judged
    as the float error.
    When the set value of this simulation is 0, no float error occurs.
    When this simulation is executed, the current set value is displayed.
    Enter the adjustment value with [ ] [ ] key and press [START] key. The setting is saved and
    the display is shifted to the sub code input standby menu. 
    Setting range: 0 – 99 (Copes with margin 0 – 99 pixels.)
    Default: 30 (30 pixels)
    [Operation]
    The operation is similar to simulation 9-04.
    43 01 Fusing temperature setting 
    (Normal copy)[Function]
    Used to set the fusing temperature of 3rd or later sheet. (For 1st and 2nd sheets, SIM 43-14 is
    used.)
    When this simulation is executed, the current set code number is displayed. Press [ ] [ ] key
    to change the setting and press [START] key to save the setting into the EERPOM. 
    The machine goes into the sub code entry standby mode.
    The [Exposure mode selector] key is used to select the mode.
    [Operation]
    1) Press [Exposure mode selector] key to change the mode. 
    2) Press [ ] [ ] key to set the value.
    3) Press [START] key to fix the code number. Main 
    codeSub 
    codeContents Details of function/operation
    Sensor Signal Display lamp
    Paper exit sensor POD Photoconductor cartridge 
    replacement lamp
    Paper entry sensor   PPD1 Developer cartridge replacement 
    lamp
    Duplex sensor PPD2 JAM lamp  
    2nd CS sensor PPD3 2nd cassette lamp  
    * The cassette feed and the manual feed are controlled similarly.CodeSet temperature  
    (°C)Remark CodeSet temperature  
    (°C)Remark
    0 170  5 195 Default
    1 175  6 200
    2 180  7 205
    3 185  8 210
    4 190
    Mode Display item
    Main cassette paper 
    feed,  2nd cassette 
    feedAE mode lamp  
    Manual paper feed   TEXT mode lamp   
    						
    							MX-B200  SIMULATION, TROUBLE CODES  10 - 11 43 04 Fusing temperature setting 
    in multi copy[Function]
    For 20th sheet or later in multi copy, the fusing temperature is automatically changed from the
    temperature set with simulation 43-01 to the temperature set with this simulation.
    When this simulation is executed, the current set code number is displayed. Enter the code
    number and press [START] key to change the setting.
    [Operation]
    The operation is similar to simulation 43-01.
    09 Postcard size paper fusing 
    control setting[Function]
    When this simulation is executed, the currently set code number is displayed. 
    Enter the code number and press [START] key, and the setting is changed.
    11 Postcard size paper fusing 
    temperature setting[Function]
    When the simulation is executed, the current set value is displayed.
    Press [UP/UP] key to switch the setting. Press [START] key to write into the EEPROM. 
    The machine enters the sub code input standby state. Main 
    codeSub 
    codeContents Details of function/operation
    * The cassette feed and the manual feed are controlled similarly.Code Set temperature (°C) Remark
    0 165
    1 170
    2 175
    3 180
    4 185
    5 190
    6 195
    7 200
    Mode Display lampDefault
    Europe
    Main cassette paper feed,  2nd cassette 
    feedAE mode lamp 3
    Manual paper feed TEXT mode lamp 3
    Main cassette paper feed,  2nd cassette 
    feed (small-size)PHOTO mode lamp 3
    Manual paper feed (small-size) AE mode lamp
    TEXT mode lamp3
    Code Shift temperature (°C) Remark
    0 Cancel Default
    1Set
    Code Shift temperature (°C) Remark
    0 160
    1 165
    2 170
    3 175
    4 180
    5 185
    6 190
    7 195 Default
    8 200 
    						
    							MX-B200  SIMULATION, TROUBLE CODES  10 - 12 43 14 Fusing start temperature 
    setting[Function]
    When this simulation is started, the currently set code number is displayed.
    Press [ ] [ ] key to switch the setting, and press [START] key to save it to the EEPROM. 
    The machine goes to the sub code entry standby mode.
    Switching to each mode is made by [Density Select] key. The set value of the selected mode is 
    displayed on the 7seg display.
    ∗The cassette feed and the manual feed are controlled similarly.
    [Operation]
    The operation is similar to simulation 43-01.
    15 Postcard size paper fusing 
    control cycle synchronization 
    setting[Function]
    When this simulation is executed, the currently set code number is displayed.
    When [UP/UP] key is pressed, setting is switched. When [START] key is pressed, setting is 
    written into the EEPROM, and the machine enters the sub code input standby state. 
    (Setting range: 0 - 20, Default: 0)
    ∗When set to 0, the setting is canceled and the fusing temperature control and the paper 
    pass timing are not synchronized. The conventional control (control same as other paper) is 
    performed. 
    ∗When set to 1 - 20, postcards are passed in synchronization with the fusing temperature 
    control, ensuring stable fusing. However, the CPM becomes smaller.
    ∗When set to 1 - 20 and when set value x 0.5°C + control temperature, the fusing heater 
    lamp is controlled to be OFF. Main 
    codeSub 
    codeContents Details of function/operation
    Code Set temperature (°C) Remark
    0 160
    1 165
    2 170
    3 175
    4 180
    5 185
    6 190
    7 195
    8 200
    9 205
    10 210
    Mode LEDDefault
    Europe
    Maine cassette paper feed & 
    2nd cassette paper feedAE mode lamp 8
    Manual paper feed TEXT mode lamp 8
    CodeSynchronization 
    settingFusing heater lamp OFF 
    timing temperatureRemark
    0 Cancel - Default
    1 Setting + 0.5°C
    n n nn n n
    6 + 3.0°Cn n nn n n
    20 + 10.0°C 
    						
    							MX-B200  SIMULATION, TROUBLE CODES  10 - 13 46 01 Copy density adjustment 
    (300dpi)[Function]
    Copy density is set for each mode.
    When this simulation is executed, the current set value is displayed in 2 digits (Default: 50).
    Change the set value and press [START] key to make a copy under the set value.
    When the set value is increased, the copy becomes darker. When the set value is decreased,
    the copy becomes lighter.
    In this case, only Exp.3 copy is made. When, however, the setting is made to make darker copy,
    Exp.1 and Exp.5 copies also become darker. When made to lighter copy, Exp1. and Exp.5 cop-
    ies become lighter, too.
    Press [Exposure mode selector] key to switch the mode. The set value of the selected mode is
    displayed on the LED/display. (Adjustment value: 1 – 99) 
    The setting procedure of the magnification ratio is the same as that to copy operation.
    [Operation]
    1) Press [Exposure mode selector] key to change the mode. 
    2) Press [ ] [ ] key to set the value. 
    3) [START] Fixing and printing value
    ∗Print is started in the set mode.
    ∗To cancel the manual paper feed tray paper empty MSG, press [Any] key. 
    ∗When the AE mode exposure adjustment is made, put the chart on the rear side of the 
    document table to avoid the center section (10cm).
    02 Copy density adjustment 
    (600dpi)[Function]
    Copy density is set for each mode.
    When this simulation is executed, the current set value is displayed in 2 digits (Default: 50).
    Change the set value and press [START] key to make a copy under the set value.
    When the set value is increased, the copy becomes darker. When the set value is decreased,
    the copy becomes lighter.
    In this case, only Exp.3 copy is made. When, however, the setting is made to make darker copy,
    Exp.1 and Exp.5 copies also become darker. When made to lighter copy, Exp1. and Exp.5 cop-
    ies become lighter, too.
    Press [Exposure mode selector] key to switch the mode. (Adjustment value: 1 – 99) 
    [Operation]
    The operation is similar to simulation 46-01. Main 
    codeSub 
    codeContents Details of function/operation
    Mode Display lamp Default
    AE mode (300dpi) AE mode lamp 50
    TEXT mode (300dpi) TEXT mode lamp 50
    PHOTO mode PHOTO mode lamp 50
    TS mode (TEXT) (300dpi) TEXT mode lamp
    PHOTO mode lamp50
    TS mode (AE) (300dpi) AE mode lamp
    PHOTO mode lamp50
    Dither mode AE mode lamp
    TEXT mode lamp
    PHOTO mode lamp50
    Mode Display lamp Default
    AE mode (600dpi) AE mode lamp 50
    TEXT mode (600dpi) TEXT mode lamp 50
    PHOTO mode PHOTO mode lamp 50
    TS mode (TEXT) (600dpi) TEXT mode lamp
    PHOTO mode lamp50
    TS mode (AE) (600dpi) AE mode lamp
    PHOTO mode lamp50
    Dither mode AE mode lamp
    TEXT mode lamp
    PHOTO mode lamp50 
    						