MX-B200 SIMULATION, TROUBLE CODES 10 - 4 8 01 Developing bias[Function] When [START] key is pressed, the developing bias signal is turned ON for 30sec. When, however, an actual output value is measured, use simulation 25-01. After completion of this process, the machine goes into the sub code entry standby mode. 02 Main charger (Grid high)[Function] When [START] key is pressed, the main charger is outputted for 30sec in the grid voltage HIGH move. After completion of this process, the machine goes into the sub code entry standby mode. 03 Grid voltage (Low)[Function] When [START] key is pressed, the main charger is outputted for 30sec in the grid voltage LOW move. After completion of this process, the machine goes into the sub code entry standby mode. 06 Transfer charger[Function] When [START] key is pressed, the transfer charger is outputted for 30sec. After completion of this process, the machine goes into the sub code entry standby mode. 10 Toner motor aging[Function] When [START] key is pressed, the toner motor is rotated for 30sec. After completion of this process, the machine goes into the main code entry standby mode. 14 Cancel of troubles other than U2[Function] Used to cancel troubles other than U2. ∗Cancel troubles such as H trouble which writes data into EEPROM, and perform hardware reset. 16 Cancel of U2 trouble[Function] Used to cancel U2 trouble. When [START] key is pressed, check sum of the total counter in the EEPROM is rewritten and hardware reset is made. 20 01 Maintenance counter clear[Function] When [START] key is pressed, the maintenance counter value is cleared to display “000,000.” The upper three digits and the lower three digits of “000,000” are displayed on the 7seg display. 21 01 Maintenance cycle setting[Function] The code of the currently set maintenance cycle value (default display) is displayed and the set data are saved. 22 01 Maintenance counter display[Function] When [START] key is pressed, the maintenance counter value is displayed. The display method is the same as SIM20-01. 02 Maintenance preset display[Function] When [START] key is pressed, the number of sheets (25,000 sheets, etc.) corresponding to the code set with SIM21-01 is displayed. The display method of the value is the same as SIM20-01. 04 JAM total counter display[Function] The JAM total counter is displayed. [Operation] 05 Total counter display[Function] The total counter value is displayed. [Operation] The operation is similar to simulation 22-04. Main codeSub codeContents Details of function/operation Code number Setting Remark 0 3,000 sheets 1 6,000 sheets 2 9,000 sheets 3 13,000 sheets 4 25,000 sheets Default 5 Free (999,999 sheets) The count value is displayed in 3 digits X 2 times repeatedly. 01 2 →Bla nk→34 5→Bla nk→01 2 0. 7s0.3s 0. 7s1.0s 0. 7s
![](/img/blank.gif)
MX-B200 SIMULATION, TROUBLE CODES 10 - 5 22 06 Developer counter display[Function] When [START] key is pressed, the developer counter data are acquired and displayed. The display method of the value is the same as SIM20-01. 08 SPF counter display (Option)[Function] The SPF counter is displayed. [Operation] The operation is similar to simulation 22-04. 12 Drum counter display[Function] The drum counter is displayed. [Operation] The operation is similar to simulation 22-04. 13 CRUM type display[Function] When [START] key is pressed, the CRUM type which is currently set (written) in the CRUM chip is displayed. 14 ROM version display[Function] The P-ROM version is displayed. [Operation] The operation is similar to simulation 22-04. 17 Copy counter display[Function] The copy counter is displayed. [Operation] The operation is similar to simulation 22-04. 18 Printer counter display[Function] The printer counter is displayed. [Operation] The operation is similar to simulation 22-04. 19 Scanner mode counter display[Function] The scanner mode counter is displayed. [Operation] The operation is similar to simulation 22-16. 21 Scanner counter display[Function] The scanner counter is displayed. [Operation] The operation is similar to simulation 22-04. 22 SPF JAM counter display (Option)[Function] The SPF JAM counter is displayed. [Operation] The operation is similar to simulation 22-04. 24 01 JAM total counter clear[Function] When [START] key is pressed, the JAM total counter is cleared to 0 and 000,000 is displayed on the LED/display. [Operation] The operation is similar to simulation 22-04. 04 SPF counter clear (Option)[Function] When [START] key is pressed, the SPF counter value is cleared to 0 and 000,000 is displayed on the LED/display. [Operation] The operation is similar to simulation 22-04. 06 Developer counter clear[Function] When [START] key is pressed, the developer counter value is cleared to 0. The display method of the value is the same as SIM20-01. Main codeSub codeContents Details of function/operation Code number CRUM type 00 Unsetting 01 BTA-A 02 BTA-B 03 BTA-C 99 Conversion Code number Version 0 Main unit Program
![](/img/blank.gif)
MX-B200 SIMULATION, TROUBLE CODES 10 - 6 24 07 Drum counter clear[Function] When [START] key is pressed, the drum counter value is cleared to 0, and 000,000 is dis- played on the LED/display. [Operation] The operation is similar to simulation 22-04. 08 Copy counter clear[Function] When [START] key is pressed, the copy counter value is cleared to 0, and 000,000 is dis- played on the LED/display. [Operation] The operation is similar to simulation 22-04. 09 Printer counter clear[Function] When [OK]/[START] key is pressed, the printer counter value is cleared to 0, and 000,000 is displayed on the LED/display. [Operation] The operation is similar to simulation 22-04. 13 Scanner counter clear[Function] When [OK]/[START] key is pressed, the scanner counter value is cleared to 0, and 000,000 is displayed on the LED/display. [Operation] The operation is similar to simulation 22-04. 14 SPF JAM total counter clear (Option)[Function] When [START] key is pressed, the SPF JAM total counter value is cleared to 0, and 000,000 is displayed on the LED/display. [Operation] The operation is similar to simulation 22-04. 15 Scanner mode counter clear[Function] When [START] key is pressed, the scanner mode counter value is cleared to 0, and 000,000 is displayed on the LED/display. [Operation] The operation is similar to simulation 22-16. 25 01 Main motor operation check (Cooling fan motor rotation check)[Function] When [START] key is pressed, the main motor is operated for 30sec. To reduce toner consumption, if the developing unit is installed, the developing bias, the main charger, and the grid are also outputted. In this case, laser discharge is required when stopping the motor, the polygon motor is also operated at the same time. Check for installation of the developing unit. If it is not installed, the high voltage above is not outputted and only the motor is rotated. To check the developing bias, install the developing unit. After completion of 30sec operation, the machine goes into the sub code entry standby mode. 10 Polygon motor ON[Function] When [START] key is pressed, the Bios is called to rotate the polygon motor for 30sec. After completion of 30sec operation, the operation is turned off with the Bios and the machine goes into the sub code entry standby mode. 26 02 SPF setup (Option)[Function] When this simulation is executed, the current set SPF is displayed. Enter the code number cor- responding to the desired SPF and press [START] key to save the setting. 03 2nd cassette setup (Option)[Function] When this simulation is executed, the current set 2nd cassette is displayed. Enter the code number corresponding to the desired 2nd cassette and press [START] key to save the setting. Main codeSub codeContents Details of function/operation Code number SPF 0SPF NO 1SPF YES Code number 2nd cassette 0 2nd cassette NO 1 2nd cassette YES
![](/img/blank.gif)
MX-B200 SIMULATION, TROUBLE CODES 10 - 7 26 06 Destination setup[Function] When this simulation is executed, the current set destination is displayed. Enter the code num- ber corresponding to the desired destination and press [OK]/[START] key to save the setting. * Code number 2 and 3 cannot be selected. [Operation] The operation is similar to simulation 26-02. 07 Machine conditions check[Function] When this simulation is executed, the current machine setting is displayed. 20 Rear edge void setup[Function] When this simulation is executed, the current set rear edge void is displayed. Enter the code number corresponding to the desired rear edge void and press [START] key to save the setting. [Operation] The operation is similar to simulation 26-02. 30 CE mark support control ON/OFF[Function] When this simulation is executed, the current set CE mark support control is displayed. Enter the code number corresponding to the desired CE mark support control and press [START] key to save the setting. [Operation] The operation is similar to simulation 26-02. 37 Cancel of stop at developer life over[Function] When this simulation is executed, the current setting is displayed. When the code number is entered and [START] key is pressed, the setting is changed. 39 Memory capacity check[Function] When the simulation is executed, the currently installed SDRAM of the main unit is displayed. 40 Polygon motor OFF time setup (Time required for turning OFF after completion of printing)[Function] When this simulation is executed, the current setting is displayed. Enter the code number corre- sponding to the desired setting and press [START] key to save the setting. [Operation] The operation is similar to simulation 26-02. Main codeSub codeContents Details of function/operation Code number Destination 0 Inch series 1 EX Japan AB series 2 Japan AB series 3 China CPM Copy quantity Remark 20 CPM 20 Code number Setting Remark 0 Rear edge void NO 1 Rear edge void YES Default Code number Setting Remark 0 CE mark support control OFF Default (100V series) 1 CE mark support control ON Code number Setup Remark 0 Stop at developer life over 1 Cancel of stop at developer life over Default Code number Setting Remark 32 32 MBYTE Code number Setting Display item Remark 00sec0 1 30sec 30 Default 2 60sec 60 3 90sec 90
![](/img/blank.gif)
MX-B200 SIMULATION, TROUBLE CODES 10 - 8 26 42 Transfer ON timing control setup[Function] Enter the code number with [UP/UP] key and press [START] key, and the entered set value is saved and the machine enters the sub code input standby state. Use [Density Select] key to select a mode. The set value of the selected mode is displayed in the 7seg display. Main codeSub codeContents Details of function/operation * The default value, 11, of the transfer ON timing indicates 236msec passed from PS release. * When set to 0, it is same as setting to the default, 11. * The transfer ON timing can be adjusted to 236msec ± 2ms. * The default 50 of the transfer OFF timing indicates 210msec passed from PPD1OFF.Mode LED Default Setting range Front surface paper lead edgeAE mode lamp 11 0 - 21 Front surface paper rear edgeTEXT mode lamp 50 1 - 99 Back surface paper lead edgePHOTO mode lamp 11 0 - 21 Back surface paper rear edgeAE mode lamp TEXT mode lamp50 1 - 99 Code number Setting Code number Setting 0 Default (236 msec) 11 Default (236 msec) 1 –20 msec 12 +2 msec 2 –18 msec 13 +4 msec 3 –16 msec 14 +6 msec 4 –14 msec 15 +8 msec 5 –12 msec 16 +10 msec 6 –10 msec 17 +12 msec 7 –8 msec 18 +14 msec 8 –6 msec 19 +16 msec 9 –4 msec 20 +18 msec 10 –2 msec 21 +20 msec Code Setting Remark 1 –98 msec . . . . . . 49 –2 msec 50 0 msec Default 51 +2 msec . . . . . . 99 +98 msec
![](/img/blank.gif)
MX-B200 SIMULATION, TROUBLE CODES 10 - 9 26 43 Side void setup[Function] When this simulation is executed, the currently set code of the side void quantity is displayed (initial display), and the set data are saved. (Setting range: 0 – 10, Default: 4 (= One side 2.0mm)) * When the adjustment value is increased by 1, the side void is changed as follows: Side void adjustment: The side void is increased by 0.5mm. (The side void of Set value x 0.5mm is made.) [Operation] The operation is similar to simulation 09-04. 54γ life correction setting[Function] Used to set the γ life correction. When this simulation is executed, the current set code number is displayed. Enter the desired code number and press [START] key to save the setting. (Setting range: 0 – 1, default: 1) [Operation] The operation is similar to simulation 26-02. 62 Energy-save mode copy lamp setup[Function] Used to set half-ON /OFF of the copy lamp in the pre-heat mode. When this simulation is executed, the current set code number is displayed. Enter the desired code number and press [START] key to save the setting. [Operation] The operation is similar to simulation 26-02. 69 Used to set the operating conditions for toner near end[Function] This simulation is used to set the operating conditions for toner near end. The setting mode is switched by [Density select] key. The set value of the selected mode is displayed on the 7seg display. When the code number is entered and [START] key is pressed, the setting is switched. Main codeSub codeContents Details of function/operation Code Setting Remark 00 mm 10.5 mm 21.0 mm 31.5 mm 4 2.0 mm Default 52.5 mm 63.0 mm 73.5 mm 84.0 mm 94.5 mm 10 5.0 mm Code number Setting Remark 0OFF 1 ON Default Code number Setting Remark 0 Copy lamp OFF 1 Copy lamp half-ON Default Lighting LED: AE mode lamp Code number Setting contents 0 Toner near end is displayed 1 Toner near end is not displayed Code number Setting contents 1 Operation setting 1 2 Operation setting 2 3 Operation setting 3
![](/img/blank.gif)
MX-B200 SIMULATION, TROUBLE CODES 10 - 10 30 01 Paper sensor status display[Function] The paper sensor status is displayed on the LED. ∗Since the manual paper feed sensor is a single bypass sensor, its status is not displayed. 41 06 OC cover float detection level adjustment (Option)[Function] When this simulation is executed, the current set value is displayed. When [START] key is pressed, the mirror base unit moves to the SPF scan position to acquire the OC cover float detection level. When the mirror base unit returns to the home position, the acquired value is displayed. If the adjustment is NG, the following message is displayed. Misfeed lamp lights up, and the 7seg display remains unchanged. Note that, this simulation must be executed with the OC cover closed. ∗If the value is 0, float detection is not performed in normal jobs. 07 OC cover float detection margin setting (Option)[Function] For the number of pixels between black markers on the SPF scanning position saved in 41-06: (OC cover float detection level adjustment), if the number of pixels between the markers when processing float detection is less than the number of pixels set with this simulation, it is judged as the float error. When the set value of this simulation is 0, no float error occurs. When this simulation is executed, the current set value is displayed. Enter the adjustment value with [ ] [ ] key and press [START] key. The setting is saved and the display is shifted to the sub code input standby menu. Setting range: 0 – 99 (Copes with margin 0 – 99 pixels.) Default: 30 (30 pixels) [Operation] The operation is similar to simulation 9-04. 43 01 Fusing temperature setting (Normal copy)[Function] Used to set the fusing temperature of 3rd or later sheet. (For 1st and 2nd sheets, SIM 43-14 is used.) When this simulation is executed, the current set code number is displayed. Press [ ] [ ] key to change the setting and press [START] key to save the setting into the EERPOM. The machine goes into the sub code entry standby mode. The [Exposure mode selector] key is used to select the mode. [Operation] 1) Press [Exposure mode selector] key to change the mode. 2) Press [ ] [ ] key to set the value. 3) Press [START] key to fix the code number. Main codeSub codeContents Details of function/operation Sensor Signal Display lamp Paper exit sensor POD Photoconductor cartridge replacement lamp Paper entry sensor PPD1 Developer cartridge replacement lamp Duplex sensor PPD2 JAM lamp 2nd CS sensor PPD3 2nd cassette lamp * The cassette feed and the manual feed are controlled similarly.CodeSet temperature (°C)Remark CodeSet temperature (°C)Remark 0 170 5 195 Default 1 175 6 200 2 180 7 205 3 185 8 210 4 190 Mode Display item Main cassette paper feed, 2nd cassette feedAE mode lamp Manual paper feed TEXT mode lamp
![](/img/blank.gif)
MX-B200 SIMULATION, TROUBLE CODES 10 - 11 43 04 Fusing temperature setting in multi copy[Function] For 20th sheet or later in multi copy, the fusing temperature is automatically changed from the temperature set with simulation 43-01 to the temperature set with this simulation. When this simulation is executed, the current set code number is displayed. Enter the code number and press [START] key to change the setting. [Operation] The operation is similar to simulation 43-01. 09 Postcard size paper fusing control setting[Function] When this simulation is executed, the currently set code number is displayed. Enter the code number and press [START] key, and the setting is changed. 11 Postcard size paper fusing temperature setting[Function] When the simulation is executed, the current set value is displayed. Press [UP/UP] key to switch the setting. Press [START] key to write into the EEPROM. The machine enters the sub code input standby state. Main codeSub codeContents Details of function/operation * The cassette feed and the manual feed are controlled similarly.Code Set temperature (°C) Remark 0 165 1 170 2 175 3 180 4 185 5 190 6 195 7 200 Mode Display lampDefault Europe Main cassette paper feed, 2nd cassette feedAE mode lamp 3 Manual paper feed TEXT mode lamp 3 Main cassette paper feed, 2nd cassette feed (small-size)PHOTO mode lamp 3 Manual paper feed (small-size) AE mode lamp TEXT mode lamp3 Code Shift temperature (°C) Remark 0 Cancel Default 1Set Code Shift temperature (°C) Remark 0 160 1 165 2 170 3 175 4 180 5 185 6 190 7 195 Default 8 200
![](/img/blank.gif)
MX-B200 SIMULATION, TROUBLE CODES 10 - 12 43 14 Fusing start temperature setting[Function] When this simulation is started, the currently set code number is displayed. Press [ ] [ ] key to switch the setting, and press [START] key to save it to the EEPROM. The machine goes to the sub code entry standby mode. Switching to each mode is made by [Density Select] key. The set value of the selected mode is displayed on the 7seg display. ∗The cassette feed and the manual feed are controlled similarly. [Operation] The operation is similar to simulation 43-01. 15 Postcard size paper fusing control cycle synchronization setting[Function] When this simulation is executed, the currently set code number is displayed. When [UP/UP] key is pressed, setting is switched. When [START] key is pressed, setting is written into the EEPROM, and the machine enters the sub code input standby state. (Setting range: 0 - 20, Default: 0) ∗When set to 0, the setting is canceled and the fusing temperature control and the paper pass timing are not synchronized. The conventional control (control same as other paper) is performed. ∗When set to 1 - 20, postcards are passed in synchronization with the fusing temperature control, ensuring stable fusing. However, the CPM becomes smaller. ∗When set to 1 - 20 and when set value x 0.5°C + control temperature, the fusing heater lamp is controlled to be OFF. Main codeSub codeContents Details of function/operation Code Set temperature (°C) Remark 0 160 1 165 2 170 3 175 4 180 5 185 6 190 7 195 8 200 9 205 10 210 Mode LEDDefault Europe Maine cassette paper feed & 2nd cassette paper feedAE mode lamp 8 Manual paper feed TEXT mode lamp 8 CodeSynchronization settingFusing heater lamp OFF timing temperatureRemark 0 Cancel - Default 1 Setting + 0.5°C n n nn n n 6 + 3.0°Cn n nn n n 20 + 10.0°C
![](/img/blank.gif)
MX-B200 SIMULATION, TROUBLE CODES 10 - 13 46 01 Copy density adjustment (300dpi)[Function] Copy density is set for each mode. When this simulation is executed, the current set value is displayed in 2 digits (Default: 50). Change the set value and press [START] key to make a copy under the set value. When the set value is increased, the copy becomes darker. When the set value is decreased, the copy becomes lighter. In this case, only Exp.3 copy is made. When, however, the setting is made to make darker copy, Exp.1 and Exp.5 copies also become darker. When made to lighter copy, Exp1. and Exp.5 cop- ies become lighter, too. Press [Exposure mode selector] key to switch the mode. The set value of the selected mode is displayed on the LED/display. (Adjustment value: 1 – 99) The setting procedure of the magnification ratio is the same as that to copy operation. [Operation] 1) Press [Exposure mode selector] key to change the mode. 2) Press [ ] [ ] key to set the value. 3) [START] Fixing and printing value ∗Print is started in the set mode. ∗To cancel the manual paper feed tray paper empty MSG, press [Any] key. ∗When the AE mode exposure adjustment is made, put the chart on the rear side of the document table to avoid the center section (10cm). 02 Copy density adjustment (600dpi)[Function] Copy density is set for each mode. When this simulation is executed, the current set value is displayed in 2 digits (Default: 50). Change the set value and press [START] key to make a copy under the set value. When the set value is increased, the copy becomes darker. When the set value is decreased, the copy becomes lighter. In this case, only Exp.3 copy is made. When, however, the setting is made to make darker copy, Exp.1 and Exp.5 copies also become darker. When made to lighter copy, Exp1. and Exp.5 cop- ies become lighter, too. Press [Exposure mode selector] key to switch the mode. (Adjustment value: 1 – 99) [Operation] The operation is similar to simulation 46-01. Main codeSub codeContents Details of function/operation Mode Display lamp Default AE mode (300dpi) AE mode lamp 50 TEXT mode (300dpi) TEXT mode lamp 50 PHOTO mode PHOTO mode lamp 50 TS mode (TEXT) (300dpi) TEXT mode lamp PHOTO mode lamp50 TS mode (AE) (300dpi) AE mode lamp PHOTO mode lamp50 Dither mode AE mode lamp TEXT mode lamp PHOTO mode lamp50 Mode Display lamp Default AE mode (600dpi) AE mode lamp 50 TEXT mode (600dpi) TEXT mode lamp 50 PHOTO mode PHOTO mode lamp 50 TS mode (TEXT) (600dpi) TEXT mode lamp PHOTO mode lamp50 TS mode (AE) (600dpi) AE mode lamp PHOTO mode lamp50 Dither mode AE mode lamp TEXT mode lamp PHOTO mode lamp50