    							MX-B200    DISASSEMBLY AND ASSEMBLY  8 - 18 1) Remove the E-ring.
    2) Remove the bearing.
    3) Remove the paper guide unit.
    4) Remove the paper exit roller.
    D. Set sensor, scan front sensor
    1) Remove the set sensor.
    2) Remove the scan front sensor.
    3) Disconnect the connectors.
    * When assembling, attach the blue harness to the marking B side
    of the sensor, and attach the orange harness to the opposite side
    sensor.
    E. Transport roller
    1) Remove the actuator.
    2) Remove the transport roller.
    3) Remove the gear and the bearing.
    1)
    3) 2)
    4)
    1)
    3)
    3)
    2)B
    3)
    1)2) 
    						
    							MX-B200  ADJUSTMENTS  9 - 1
    [9] ADJUSTMENTS
    1. Optical section
    A. Copy magnification ratio adjustment
    The copy magnification ratio must be adjusted in the main scan-
    ning direction and in the sub scanning direction. To adjust, use
    SIM 48-1.
    (1) Outline
    The main scanning (front/rear) direction magnification ratio adjust-
    ment is made automatically or manually.
    Automatic adjustment: The width of the reference line marked on
    the shading correction plate is scanned to perform the main scan-
    ning (front/rear) direction magnification ratio adjustment automati-
    cally.
    Manual adjustment: The adjustment is made by [Copy quantity]
    keys operations. (In either of the automatic and manual adjust-
    ments, the zoom data register set value is changed for adjustment.)
    The magnification ratio in the sub scanning direction is adjusted by
    changing the carriage (scanner) scanning speed.
    (2) Main scanning direction magnification ratio 
    adjustment
    a. Cases when the adjustment is required
    1) When the main PWB is replaced.
    2) When the EEPROM in the main PWB is replaced.
    3) When U2 trouble occurs.
    4) When repairing or replacing the optical section.
    b. Necessary tools
     Screwdriver (+)
    
    c. Adjustment procedure
    1) Set the scale vertically on the document table. (Use a long
    scale for precise adjustment.)
    2) Set the copy magnification ratio to 100%.
    3) Make a copy on A4 or 81/2 x 11 paper.
    4) Measure the length of the copied scale image.5) Calculate the main scanning direction magnification ratio. 
    Main scanning direction magnification ratio
    6) Check that the copy magnification ratio is within the specified
    range. If it is not within the specified range, perform the follow-
    ing procedures.
    7) Execute SIM 48-1 to select the main scanning direction copy
    magnification ratio adjustment mode.
    To select the adjustment mode, use the [Exposure mode selec-
    tor] key.
    In the case of the automatic adjustment, when the START switch is
    pressed, the mirror base unit moves to the white plate for shading
    to scan the width of the reference line, calculating the correction
    value and displaying and storing this value.
    After execution of the automatic adjustment, go out from the simu-
    lation mode and make a copy to check the magnification ratio.
    If the magnification ratio is not in the specified range (100 ± 1.0%),
    manually adjust as follows.
    8) Enter the new set value of main scanning direction copy magni-
    fication ratio with the copy quantity key, and press the [START]
    key.
    9) Change the set value and repeat the adjustment until the ratio
    is within the specified range.
    When the set value is changed by 1, the magnification ratio is
    changed by 0.1%.
    (3) Sub scanning direction copy magnification ratio
    a. Cases when the adjustment is required
    1) When the scanner unit drive section is disassembled or the part
    is replaced.
    2) When the main PWB is replaced.
    3) When the EEPROM in the main PWB is replaced.
    4) When U2 trouble occurs.
    b. Necessary tools
    
    =Copy image dimensions
    X 100 (%)
    Original dimension
    Adjustment mode Display lamp Default
    Main scanning direction 
    magnification ratioTEXT mode lamp 50
    OC mode sub scan 
    direction magnification ratioPHOTO mode lamp 50
    100 110 120130150140mm
    1/2mmJAPANHARDENED
    STAINLESS
    Shizuoka
    100110120130150140mm
    1/2mmJAPANHARDENED
    STAINLESS
    Shi zuoka
    110
    10 20
    1020
    (When a 100mm scale is used as the original.)
    Paper feed
    direction
    ReferenceComparison pointOriginal (Scale)
    Copy 
    						
    							MX-B200  ADJUSTMENTS  9 - 2 c. Adjustment procedure
    1) Set the scale on the document table as shown below. (Use a
    long scale for precise adjustment.)
    2) Set the copy magnification ratio to 100%.
    3) Make a copy on A4 or 81/2 x 11 paper.
    4) Measure the length of the copied scale image.
    5) Calculate the sub scanning direction copy magnification ratio
    using the formula below.
    6) Check that the actual copy magnification ratio is within the
    specified range. (100 ± 1.0%).
    If it is not within the specified range, perform the following pro-
    cedures.
    7) Execute SIM 48-1 to select the sub scanning direction copy
    magnification ratio adjustment mode.
    To select the adjustment mode, use the [Exposure mode selec-
    tor] key. (PHOTO lamp ON)
    8) Enter the new set value of sub scanning direction copy magnifi-
    cation ratio with the [Copy quantity] keys, and press the
    [START] key.
    Repeat procedures 1) - 8) until the sub scanning direction actual
    copy magnification ratio in 100% copying is within the specified
    range.
    When the set value is changed by 1, the magnification ration is
    changed by 0.1%.
    B. Image position adjustment
    There are following eleven kinds of image position adjustments,
    which are made by laser control except for the image scan start
    position adjustment. For the adjustments, SIM 50-01 and  50-10 are
    used.
    To select the adjustment mode with SIM 50-01, use the [Exposure
    mode selector] key.
    The relationship between the adjustment modes and the lighting
    lamps are as shown in the table below.
    To select the adjustment mode with SIM 50-10, use the [Exposure
    mode selector] key.
    The relationship between the adjustment modes and the lighting
    lamps are as shown in the table below.
    Machine with the multi manual paper feed unit
    :Supported for the installing model and skipped for non-install-
    ing mode.
    (1) Lead edge adjustment
    1) Set a scale to the center of the paper lead edge guide as shown
    below, and cover it with B4 or 8 1/2 x 14 paper. =Copy image dimensions
    X 100 (%)
    Original dimension
    100110 120130150140mm
    1/2mmJAPANHARDDENCD
    STAINLESS
    Shizuoka
    100110 120130150140mm
    1/2mmJAPANHARDDENCD
    STAINLESS
    Shi zuoka
    110
    1020
    10 20
    Original (Scale)
    Paper feed
    direction
    ReferenceComparison point
    Copy
    No. Mode SIM
    1 Print start position 
    (Main cassette paper feed)50-01
    2 Print start position (Manual paper feed) 50-01
    3 Image lead edge void amount 50-01
    4 Image scan start position 50-01
    5 Image rear edge void amount 
    (Cassette paper feed)50-01
    6 Print center offset 
    (Main cassette paper feed)50-10
    7 Print center offset (Manual paper feed) 50-10
    Adjustment mode Lamp ON
    Print start position 
    (Main cassette paper feed)AE, main cassette lamp
    Print start position 
    (Manual paper feed)AE, manual feed lamp
    Image lead edge void quantity TEXT lamp
    Image scan start position PHOTO lamp
    Image rear edge void quantity AE, TEXT, PHOTO lamp
    Adjustment mode Lamp ON
    Print center offset 
    (Main cassette paper feed)AE, main cassette lamp
    Print center offset 
    (Manual paper feed)AE, manual paper feed 
    lamp
    Second side center offset TEXT lamp 
    						
    							MX-B200  ADJUSTMENTS  9 - 3 2) Execute SIM 50-01
    3) Set the print start position (AE lamp ON) (A), the lead edge void
    amount (TEXT lamp ON) (B), and the scan start position
    (PHOTO lamp ON) (C) to 0, and make a copy of a scale at
    100%.
    4) Measure the image loss amount (R mm) of the scale image.
    Set C = 10 X R (mm). (Example: Set the value of C to 30.)
    When the value of C is increased by 10, the image loss is
    decreased by 1mm. (Default: 50)
    5) Measure the distance (H mm) between the paper lead edge
    and the image print start position.
    Set A = 10 X H (mm). (Example: Set the value of A to 50.)
    When the value of A is increased by 10, the image lead edge is
    shifted to the paper lead edge by 1mm. (Default: 50)
    6) Set the lead edge void amount to B = 50 (2.5mm).
    When the value of B is increased by 10, the void amount is
    increased by about 1mm. For 25 or less, however, the void
    amount becomes zero. (Default: 50)
    (2) Image rear edge void amount adjustment
    1) Set a scale to the rear edge section of A4 or 11 x 8 1/2 paper
    size as shown in the figure below, and cover it with B4 or 8 1/2
    x 14 paper.
    2) Execute SIM 50-01 to select the image rear edge void amount
    adjustment mode.
    The set adjustment value is displayed on the copy quantity dis-
    play.
    3) Make a copy and measure the void amount of image rear edge.4) If the measurement value is out of the specified range, change
    the set value and repeat the adjustment procedure.
    The default value is 50.
    Note:The rear edge void cannot be checked with the first sheet
    after entering the simulation mode, the first sheet after turn-
    ing off/on the power, or the first sheet after inserting the
    cassette. Use the second or later sheet to check the rear
    edge void.
    (3) Center offset adjustment
    1) Set the self-made test chart for the center position adjustment
    so that its center line is aligned with the center mark of the doc-
    ument guide.
     Test chart for the center position adjustment.
    Draw a line at the center of A4 or 8 1/2 x 11 paper in the paper
    transport direction.
    2) Execute SIM 50-10 to select the print center offset (cassette
    paper feed) adjustment mode.
    The set adjustment value is displayed on the copy quantity dis-
    play.
    3) Make a copy and check that the copied center line is properly
    positioned.
    The standard value is 0 ± 2mm from the paper center.
    4) If the measured value is out of the specified range, change the
    set value and repeat the adjustment procedure.
    When the set value is increased by 1, the copy image is
    shifted by 0.1mm toward the rear frame.
     For the manual paper feed, change the manual paper feed
    adjustment mode and perform the similar procedures.
     Since the document center offset is automatically adjusted by
    the CCD which scan the reference lines (F/R) on the back of
    document guide, there is no need to adjust manually.
    5mm
    10mm
    (Example)
    Distance between paper lead
    edge and image: H = 5mm
    Image loss:
    R = 3mm
    B4 or 8 1/2″ × 14″ paper
    A4 size rear edge
    Paper rear edge Void amount (Standard value: 2 - 3mm)
    Scale image
    Document guide
    Center
    Copy paper
    (A4 or 8 1/2″ × 11″)
    (Copy A)
    (Copy B)2.0mm or less
    2.0mm or less
    Copy image
    Copy paper
    folding line
    Copy image
    Copy paper
    folding line Shift
    Shift
    (Paper feed direction) 
    						
    							MX-B200  ADJUSTMENTS  9 - 4
    2. Copy density adjustment
    A. Copy density adjustment timing
    The copy density adjustment must be performed in the following
    cases:
     When maintenance is performed.
     When the developing bias/grid bias voltage is adjusted.
     When the optical section is cleaned.
     When a part in the optical section is replaced.
     When the optical section is disassembled.
     When the OPC drum is replaced.
     When the main control PWB is replaced.
     When the EEPROM on the main control PWB is replaced.
     When the memory trouble (U2) occurs.
    B. Note for copy density adjustment
    1) Arrangement before execution of the copy density adjustment
     Clean the optical section.
     Clean or replace the charger wire.
     Check that the voltage at the high voltage section and the devel-
    oping bias voltage are in the specified range.
    C. Necessary tool for copy density adjustment
     One of the following test charts:
    UKOG-0162FCZZ, UKOG-0089CSZZ, KODAK GRAY SCALE
     B4 (14 x 8 1/2) white paper
     The user program AE setting should be 3.
    Test chart comparison table
    D. Features of copy density adjustment
    For the copy density adjustment, the image data shift function pro-
    vided in the image process LSI is used.
    List of the adjustment modes
    E. Copy density adjustment procedure
    Use SIM 46-1 to set the copy density for each copy mode.
    For selection of modes, use the [Exposure mode selector] key.
    (1) Test chart (UKOG-0162FCZZ) setting
    1) Place the test chart so that its edge is aligned with the A4 (Let-
    ter) reference line on the document table. Then place a A4
    (14 x 8 1/2) white paper on the test chart and close the docu-
    ment cover.
    (2) Perform the adjustment in each mode.
    1) Execute SIM 46-01 (300dpi). To adjust in 600dpi, execute SIM
    46-02.
    2) Select the mode to be adjusted with the exposure mode select
    key. Set the exposure level to 3 for all adjustment. (Except for
    the auto mode.) UKOG-
    0162FCZZ
    DENSITY
    No.12345678910W
    UKOG-
    0089CSZZ
    DENSITY
    No.0.1 0.2 0.3 0.5 1.9 0
    KO DAK
    GRAY
    SCALE123419A
    Auto mode Brightness 1 step only
    Manual mode Brightness 5 steps. Adjustment of only the 
    center brightness is made.
    Photo mode Brightness 5 steps. Adjustment of only the 
    center brightness is made.
    Manual T/S mode Brightness 5 steps. Adjustment of only the 
    center brightness is made.
    T/S Auto mode Brightness 1 step only
    110W23456789
    Adjustment 
    modeExposure mode
    display lampSharp gray chart 
    adjustment level
    Auto mode Auto lamp ON 3 is slightly copied.
    Manual mode Manual lamp ON 3 is slightly copied.
    Photo mode Photo lamp ON 3 is slightly copied.
    Manual T/S 
    modeManual lamp/Photo lamp ON 3 is slightly copied.
    Auto T/S 
    modeAuto lamp/Photo lamp ON 3 is slightly copied.
    Test chartWhite paper
    Exposure mode select key/display lamp
    [Exposure mode selector] key/
    display lamp (1)
    (2)
    (1) (2) 
    						
    							MX-B200  ADJUSTMENTS  9 - 5 3) Make a copy.
    Check the adjustment level (shown in the above table) of the
    exposure test chart (Sharp Gray Scale).
    (When too bright):Decrease the value displayed on the copy
    quantity display.
    (When too dark):Increase the value displayed on the copy quan-
    tity display.
    * The value can be set in the range of 1 - 99.
    3. High voltage adjustment
    A. Main charger (Grid bias)
    Note:
     Use a digital multi meter with internal resistance of 10MΩ or
    more measurement.
     After adjusting the grid LOW output, adjust the HIGH output. Do
    not reverse the sequence.
    Procedures
    1) Set the digital multi meter range to DC700V.
    2) Set the positive side of the test rod to the connector CN11-3
    (GRID) of high voltage section of the power PWB and set the
    negative side to the frame ground (power frame).
    3) Execute SIM 8-2. (The main charger output is supplied for 30
    sec in the grid voltage HIGH output mode.)
    4) Adjust the control volume (VRG1) so that the output voltage is
    580 ± 12V.
    B. DV bias check
    Procedures
    1) Set the digital multi meter range to DC500V.
    2) Set the positive side of the test rod to the connector CN-10-1
    (DV BIAS) and set the negative side to the frame ground
    (power frame).
    3) Execute SIM 8-1 to output the developing bias for 30sec, and
    check that the output is –400 ± 8V.
    4. SPF scan position automatic 
    adjustment (Option)
    Place a A4 paper (white chart) so that it covers the SPF scan glass
    and the OC glass together, and close the SPF.
    When simulation 53-08 is executed, the current adjustment value is
    displayed as the initial display.
    * Default is 1. Adjustment range is 1 – 99. Adjustment unit 1 =
    about 0.127mm
    * If the values are kept as the default values, SPF scan is not per-
    formed properly. The front area of the proper scan position may
    be scanned.
    In case of AUTO, press [START] key, and the mirror unit scans
    from the home position to the SPF scan position with the adjust-
    ment value displayed. The SPF glass cover edge position is calcu-
    lated from the difference between the SPF glass cover edge and
    the OC side document glass CCD output level. If the adjustment is
    normal, the adjusted value is displayed. If abnormal, the error LED
    lights up with the current set value displayed.
    During the error LED is lighted, when [START] key is pressed
    again, execution is performed again. Sharp Gray Scale adjustment level
    Non toner 
    save 
    mode
    Toner 
    save 
    mode
    110W23456789
    Slightly copied.
    Not copied.
    110W23456789
    Slightly copied.
    Not copied.
    VRG1
    Note: A digital multi meter with internal resistance of 1GΩ must
    be use for correct check.
     The adjustment volume is locked, and no adjustment can
    be made.
    ModeDisplay 
    itemDefault LED
    SPF scan 
    position auto 
    adjustmentAUTO 1 AE mode lamp (Option)
    SPF scan 
    position manual 
    adjustmentMANU 1 TEXT mode lamp (Option)
    VRDV 
    						
    							MX-B200  ADJUSTMENTS  9 - 6
    5. SPF mode sub scanning direction 
    magnification ratio adjustment (Option)
    Note:Before performing this adjustment, be sure to check that the
    OC mode adjustment in copying has been completed.
    1) Put a scale on the original table as shown below, and make a
    normal copy (100%) on the front and the back surfaces to
    make a test chart. 
    Note:Since the printed copy is used as a test chart, put the scale
    in paralled with the edge lines.
    2) Set the test chart on the SPF and make a copy in the normal
    ratio (100%). (Option)
    3) Compare the scale image and the actual image.
    If necessary, perform the following adjustment procedures.
    4) Execute SIM 48-05.
    5) The current sub scanning direction magnification ratio correc-
    tion value is displayed in two digits on the display section.
    6) Enter the set value and press the [START] key.
    * When there is no document in SPF, copy is inhibited.
    
    6. Automatic black level correction
    a. Cases when the adjustment is required
    1) When the main PWB is replaced.
    2) When the EEPROM in the main PWB is replaced.
    3) When U2 trouble occurs.
    4) When repairing or replacing the optical section.
    b. Adjustment procedure
    Used to acquire the black level target value used for the black level
    adjustment of white balance.
    When SIM 63-02 is executed, the current correction value is dis-
    played in 3 digits of 12bit hexadecimal number.
    Place the gray gradation chart (UKOG-0162FCZZ) used as the
    correction document so that the density 10 (black side) comes on
    the left side and that the chart is upside down at the center of the
    plate left center.
    When START key is pressed, the mirror base unit scans the chart
    and calculates the correction value.
    After completion of correction, the corrected value is displayed on
    the display section.
    * Default: 0
    * If the value is set to the default, operation is made with 0x60. Mode LED Default
    Sub scan magnification ratio 
    adjustment on the surface of SPF 
    documentAE mode lamp
    (Option)50
    Adjustment mode Spec value SIM Set valueSetting 
    range
    Sub scanning 
    direction 
    magnification ratio 
    (SPF mode)At normal: 
    ±1.0%48-5 Add 1: 
    0.1% increase
    Reduce 1: 
    0.1% decrease1 – 99
    Chart back surface 
    10 
    						
    							MX-B200  SIMULATION, TROUBLE CODES  10 - 1
    [10] SIMULATION, TROUBLE CODES
    1. Entering the simulation mode
    To enter the serviceman simulation mode, press the keys as fol-
    lows:
    [Clear] key 
    → Exposure mode selector key → [Clear] key → 
    Exposure mode selector key 
    2. Key rule
    3. List of simulations
    [] [] key:Entry of MAIN CODE/SUB CODE
    Setting of the adjustment values for the 
    adjustment-related simulations
    When [%] key is pressed simultaneously, the 
    value is displayed in the descending 
    sequence such as [0] 
    → [9], not as [0] → [1].
    [START] key: Settlement
    
    [START] key: Settlement / Print
    [Clear] key:(Interrupting operation check) Returns to the 
    upper hierarchy.
    On the initial display (00-00), it terminates the 
    simulation.
    Exits from the simulation mode.
    For a simulation of adjustment, the display 
    returns to the initial display (00-00).
     Sim 
    No.Sub 
    codeOperation
    1 01 Mirror scan operation
    02 Mirror home position sensor (MHPS) status display
    06 Aging of mirror scanning
    2 01 SPF aging operation (Option)
    02 SPF sensor status display (Option)
    03 SPF Motor ON (Option)
    5 01 Operation panel display check
    02 Fusing lamp, cooling fan operation check
    03 Copy lamp ON
    6 01 Paper feed solenoid ON
    02 Resist solenoid ON
    7 01 Warm-up display and aging with jam
    06 Intermittent aging
    08 Shift to copy with the warm-up display
    8 01 Developing bias
    02 Main charger (Grid high)
    03 Grid voltage (Low)
    06 Transfer charger
    10 Toner motor aging
    14 Cancel of troubles other than U2
    16 Cancel of U2 trouble
    20 01 Maintenance counter clear
    21 01 Maintenance cycle setting
    22 01 Maintenance counter display
    02 Maintenance preset display
    04 JAM total counter display
    05 Total counter display
    06 Developer counter display
    08 SPF counter display (Option)
    12 Drum counter display
    13 CRUM type display
    14 ROM version display
    17 Copy counter display
    18 Printer counter display
    19 Scanner mode counter display
    21 Scanner counter display
    22 SPF JAM counter display (Option)
    24 01 JAM total counter clear
    04 SPF counter clear (Option)
    06 Developer counter clear
    07 Drum counter clear
    08 Copy counter clear
    09 Printer counter clear
    13 Scanner counter clear
    14 SPF JAM total counter clear (Option)
    15 Scanner mode counter clear
    25 01 Main motor operation check 
    (Cooling fan motor rotation check)
    10 Polygon motor ON
    26 02 SPF setup (Option)
    03 2nd cassette setup (Option)
    06 Destination setup
    07 Machine conditions check
    20 Rear edge void setup
    30 CE mark support control ON/OFF
    37 Cancel of stop at developer life over
    39 Memory capacity check
    40 Polygon motor OFF time setup (Time required for 
    turning OFF after completion of printing)
    42 Transfer ON timing control setup
    43 Side void setup
    54
    γ life correction setting
    62 Energy-save mode copy lamp setup
    69
    Used to set the operating conditions for toner near end
    30 01 Paper sensor status display
    41 06 OC cover float detection level adjustment  (Option)
    07 OC cover float detection margin setting  (Option)
    43 01 Fusing temperature setting (Normal copy)
    04 Fusing temperature setting in multi copy
    09 Postcard size paper fusing control setting
    11 Postcard size paper fusing temperature setting
    14 Fusing start temperature setting
    15 Postcard size paper fusing control cycle 
    synchronization setting
    46 01 Copy density adjustment (300dpi)
    02 Copy density adjustment (600dpi)
    18 Image contrast adjustment (300dpi)
    19 Exposure mode setup (AE mode)
    20
    SPF exposure correction (Option)
    29 Image contrast adjustment (600dpi)
    30 AE limit adjustment
    31 Image sharpness adjustment
    32 Copier color reproduction setup
    48 01 Front/rear (main scanning) direction and scan (sub 
    scanning) direction magnification ratio adjustment
    05 SPF mode sub scan direction magnification ratio in 
    copying (Option)
    49 01 Flash ROM program writing mode
    50 01 Lead edge image position
    06 Copy lead edge position adjustment (SPF) 
    (Option)
    10 Center offset adjustment
    12 Document off-center adjustment
    51 02 Resist quantity adjustment
    53 08 SPF scan position automatic adjustment (Option)
    61 03 Polygon motor check (HSYNC output check)
    63 01 Shading check
    02 Black level automatic correction
    12 Light quantity stabilization wait time setting
    13 Light quantity stabilization band setting
    64 01 Self print  Sim 
    No.Sub 
    codeOperation 
    						
    							MX-B200  SIMULATION, TROUBLE CODES  10 - 2
    4. Descriptions of various simulations
    Main 
    codeSub 
    codeContents Details of function/operation
    1 01 Mirror scan operation[Function]
    When [OK]/[START] key is pressed, the home position is checked and the mirror base performs
    full scan at the speed of the set magnification ratio.
    During operation, the set magnification ratio is displayed.
    The mirror home position sensor status is displayed with the Drum replacement required lamp .
    (When the mirror is in the home position, the lamp lights up.)
    During operation, the copy lamp lights up.
    When [Clear] key is pressed, if the operation is on the way, it is terminated and the machine
    goes to the sub code entry standby mode.
    [ZOOM UP/DOWN] key (ZOOM LED ON) or [Fixed magnification ratio select] key (Fixed magni-
    fication ratio LED ON)
    ∗When [ZOOM UP/DOWN] key is pressed, the magnification ratio is displayed for a certain 
    period, and the display returns to the sub code display. 
    ∗When [%] key is being pressed, the magnification ratio can be displayed.
    02 Mirror home position sensor 
    (MHPS) status display[Function]
    Monitors the mirror home position sensor, and makes the Drum replacement required lamp
    turn on during the sensor ON status.
    06 Aging of mirror scanning[Function]
    When [START] key is pressed, the mirror base performs full scan at the speed of the set magni-
    fication ratio.
    During operation, the set magnification ratio is displayed.
    After 3sec, the mirror base performs full scan again. 
    ∗When [START] key is pressed once, the ready lamp remains OFF.
    The mirror home position sensor status is displayed on the Drum replacement required lamp.
    (The lamp is ON when the mirror is in the home position.)
    During aging, the copy lamp is ON.
    [Operation]
    The operation is similar to simulation 1-01.
    2 01 SPF aging operation 
    (Option)[Function]
    When [START] key is pressed, the set magnification ratio is obtained. For the SPF, the single-
    face document transport is performed.
    However, the operating conditions dont matter and the operation is not stopped even in case of
    a jam.
    [Operation]
    The operation is similar to simulation 1-01.
    02 SPF sensor status display 
    (Option)[Function]
    The ON/OFF status of the SPF sensors can be checked with the LED.
    When a sensor is ON, the sensor name is displayed on the LED.
    03 SPF Motor ON 
    (Option)[Function]
    When [START] key is pressed, the motor rotates for 10sec at the speed corresponding to the
    set magnification ratio.
    [Operation]
    The operation is similar to simulation 1-01.
    Sensor Display item (Option)
    Document set sensor Toner cartridge replacement required 
    lamp
    SPF document transport sensor Misfeed lamp 
    						
    							MX-B200  SIMULATION, TROUBLE CODES  10 - 3 5 01 Operation panel display 
    check[Function]
    
    When [ENTER/START] key is pressed, the LED on the operation panel lights up in all pixels.
    The status display is as follows:
     After all ON (5 sec)
    7seg panel model: 
    Returns to the sub code input standby (Sub code blinking).
     During LED check mode (All ON)
    7seg panel model: 
    When [1 UNIT UP] key is pressed, the machine goes into the individual lighting mode. 
    When [C] key is pressed, the machine enters the sub code input standby state (sub code 
    blinking).
    When [START] key is pressed, the machine goes into the key input check mode.
    In the individual lighting mode, the LED on the operation panel moves from the top of the left 
    edge to the bottom, then moves to the next right and from the top to the bottom. 
    In this manner, all LED’s are lighted sequentially. (For the 7seg display, the LED’s of three digits 
    are lighted at a time.) After completion of lighting all the LED’s, the machine returns to the all-
    lighting state. It enters the sub code input standby state 5 sec after returning to the all-lighting 
    state. (The cycle of the individual lighting mode is: ON: 300ms, OFF: 20ms)
    
    The status display is as follows:
     7seg display during the key input check mode
    7seg panel model: ---
    Every time a key on the operation panel is pressed, the number of input is added to be 
    displayed on the 7seg display.
    The key which was pressed once is not counted again. 
    When [START] key is pressed, the count is added. The machine goes to the LED lighting check 
    mode (LED all-lighting state) 3sec after that.
    02 Fusing lamp, cooling fan 
    operation check[Function]
    When [OK]/[START] key is pressed, the fusing lamp repeats ON for 500ms and OFF for 500ms
    5 times. During this period, the cooling fan motor rotates.
    03 Copy lamp ON[Function]
    When [START] key is pressed, the copy lamp turns ON for 5sec.
    6 01 Paper feed solenoid ON[Function]
    When [START] key is pressed, the selected paper feed solenoid repeats ON for 500ms and
    OFF for 500ms 20times.
    02 Resist solenoid ON[Function]
    When [START] key is pressed, the resist solenoid repeats ON for 500ms and OFF for 500ms 20
    times.
    7 01 Warm-up display and aging 
    with jam[Function]
    Copying is repeated to make the set quantity of copies.
    When the simulation is executed, warm-up is started and warm-up time is added for every sec-
    ond from 0 and displayed.
    When warm-up is completed, addition is stopped. When [Clear] key is pressed, the ready lamp
    lights up.
    After that, enter the copy quantity with [ ] [ ] key and press [START] key to repeat copying of
    the set quantity (interval 0sec).
    To cancel the simulation, turn off the power or execute a simulation which causes hardware
    reset.
    06 Intermittent aging[Function]
    Copying is repeated to make the set quantity of copies.
    When the simulation is executed, warm-up is performed and the ready lamp is lighted.
    Enter the copy quantity with the [ ] [ ] key and press [START] key, and copying is executed to
    make the set quantity of copies, and the ready state is kept for 3sec, and copying is executed
    again to make the set quantity of copies. These operations are repeated.
    To cancel the simulation, turn off the power or execute a simulation which executes hardware
    reset.
    08 Shift to copy with the 
    warm-up display[Function]
    Enter the simulation code, and warm-up is started and warm-up time is counted for every sec-
    ond from 0 and displayed.
    When [Clear] key is pressed during counting up, 0 is displayed on the display and counting is
    stopped. However, warm-up is continued.
    After completion of warm-up, counting is terminated. (The aging function is removed from simu-