MX-B200 DISASSEMBLY AND ASSEMBLY 8 - 18 1) Remove the E-ring. 2) Remove the bearing. 3) Remove the paper guide unit. 4) Remove the paper exit roller. D. Set sensor, scan front sensor 1) Remove the set sensor. 2) Remove the scan front sensor. 3) Disconnect the connectors. * When assembling, attach the blue harness to the marking B side of the sensor, and attach the orange harness to the opposite side sensor. E. Transport roller 1) Remove the actuator. 2) Remove the transport roller. 3) Remove the gear and the bearing. 1) 3) 2) 4) 1) 3) 3) 2)B 3) 1)2)
![](/img/blank.gif)
MX-B200 ADJUSTMENTS 9 - 1 [9] ADJUSTMENTS 1. Optical section A. Copy magnification ratio adjustment The copy magnification ratio must be adjusted in the main scan- ning direction and in the sub scanning direction. To adjust, use SIM 48-1. (1) Outline The main scanning (front/rear) direction magnification ratio adjust- ment is made automatically or manually. Automatic adjustment: The width of the reference line marked on the shading correction plate is scanned to perform the main scan- ning (front/rear) direction magnification ratio adjustment automati- cally. Manual adjustment: The adjustment is made by [Copy quantity] keys operations. (In either of the automatic and manual adjust- ments, the zoom data register set value is changed for adjustment.) The magnification ratio in the sub scanning direction is adjusted by changing the carriage (scanner) scanning speed. (2) Main scanning direction magnification ratio adjustment a. Cases when the adjustment is required 1) When the main PWB is replaced. 2) When the EEPROM in the main PWB is replaced. 3) When U2 trouble occurs. 4) When repairing or replacing the optical section. b. Necessary tools Screwdriver (+) c. Adjustment procedure 1) Set the scale vertically on the document table. (Use a long scale for precise adjustment.) 2) Set the copy magnification ratio to 100%. 3) Make a copy on A4 or 81/2 x 11 paper. 4) Measure the length of the copied scale image.5) Calculate the main scanning direction magnification ratio. Main scanning direction magnification ratio 6) Check that the copy magnification ratio is within the specified range. If it is not within the specified range, perform the follow- ing procedures. 7) Execute SIM 48-1 to select the main scanning direction copy magnification ratio adjustment mode. To select the adjustment mode, use the [Exposure mode selec- tor] key. In the case of the automatic adjustment, when the START switch is pressed, the mirror base unit moves to the white plate for shading to scan the width of the reference line, calculating the correction value and displaying and storing this value. After execution of the automatic adjustment, go out from the simu- lation mode and make a copy to check the magnification ratio. If the magnification ratio is not in the specified range (100 ± 1.0%), manually adjust as follows. 8) Enter the new set value of main scanning direction copy magni- fication ratio with the copy quantity key, and press the [START] key. 9) Change the set value and repeat the adjustment until the ratio is within the specified range. When the set value is changed by 1, the magnification ratio is changed by 0.1%. (3) Sub scanning direction copy magnification ratio a. Cases when the adjustment is required 1) When the scanner unit drive section is disassembled or the part is replaced. 2) When the main PWB is replaced. 3) When the EEPROM in the main PWB is replaced. 4) When U2 trouble occurs. b. Necessary tools =Copy image dimensions X 100 (%) Original dimension Adjustment mode Display lamp Default Main scanning direction magnification ratioTEXT mode lamp 50 OC mode sub scan direction magnification ratioPHOTO mode lamp 50 100 110 120130150140mm 1/2mmJAPANHARDENED STAINLESS Shizuoka 100110120130150140mm 1/2mmJAPANHARDENED STAINLESS Shi zuoka 110 10 20 1020 (When a 100mm scale is used as the original.) Paper feed direction ReferenceComparison pointOriginal (Scale) Copy
![](/img/blank.gif)
MX-B200 ADJUSTMENTS 9 - 2 c. Adjustment procedure 1) Set the scale on the document table as shown below. (Use a long scale for precise adjustment.) 2) Set the copy magnification ratio to 100%. 3) Make a copy on A4 or 81/2 x 11 paper. 4) Measure the length of the copied scale image. 5) Calculate the sub scanning direction copy magnification ratio using the formula below. 6) Check that the actual copy magnification ratio is within the specified range. (100 ± 1.0%). If it is not within the specified range, perform the following pro- cedures. 7) Execute SIM 48-1 to select the sub scanning direction copy magnification ratio adjustment mode. To select the adjustment mode, use the [Exposure mode selec- tor] key. (PHOTO lamp ON) 8) Enter the new set value of sub scanning direction copy magnifi- cation ratio with the [Copy quantity] keys, and press the [START] key. Repeat procedures 1) - 8) until the sub scanning direction actual copy magnification ratio in 100% copying is within the specified range. When the set value is changed by 1, the magnification ration is changed by 0.1%. B. Image position adjustment There are following eleven kinds of image position adjustments, which are made by laser control except for the image scan start position adjustment. For the adjustments, SIM 50-01 and 50-10 are used. To select the adjustment mode with SIM 50-01, use the [Exposure mode selector] key. The relationship between the adjustment modes and the lighting lamps are as shown in the table below. To select the adjustment mode with SIM 50-10, use the [Exposure mode selector] key. The relationship between the adjustment modes and the lighting lamps are as shown in the table below. Machine with the multi manual paper feed unit :Supported for the installing model and skipped for non-install- ing mode. (1) Lead edge adjustment 1) Set a scale to the center of the paper lead edge guide as shown below, and cover it with B4 or 8 1/2 x 14 paper. =Copy image dimensions X 100 (%) Original dimension 100110 120130150140mm 1/2mmJAPANHARDDENCD STAINLESS Shizuoka 100110 120130150140mm 1/2mmJAPANHARDDENCD STAINLESS Shi zuoka 110 1020 10 20 Original (Scale) Paper feed direction ReferenceComparison point Copy No. Mode SIM 1 Print start position (Main cassette paper feed)50-01 2 Print start position (Manual paper feed) 50-01 3 Image lead edge void amount 50-01 4 Image scan start position 50-01 5 Image rear edge void amount (Cassette paper feed)50-01 6 Print center offset (Main cassette paper feed)50-10 7 Print center offset (Manual paper feed) 50-10 Adjustment mode Lamp ON Print start position (Main cassette paper feed)AE, main cassette lamp Print start position (Manual paper feed)AE, manual feed lamp Image lead edge void quantity TEXT lamp Image scan start position PHOTO lamp Image rear edge void quantity AE, TEXT, PHOTO lamp Adjustment mode Lamp ON Print center offset (Main cassette paper feed)AE, main cassette lamp Print center offset (Manual paper feed)AE, manual paper feed lamp Second side center offset TEXT lamp
![](/img/blank.gif)
MX-B200 ADJUSTMENTS 9 - 3 2) Execute SIM 50-01 3) Set the print start position (AE lamp ON) (A), the lead edge void amount (TEXT lamp ON) (B), and the scan start position (PHOTO lamp ON) (C) to 0, and make a copy of a scale at 100%. 4) Measure the image loss amount (R mm) of the scale image. Set C = 10 X R (mm). (Example: Set the value of C to 30.) When the value of C is increased by 10, the image loss is decreased by 1mm. (Default: 50) 5) Measure the distance (H mm) between the paper lead edge and the image print start position. Set A = 10 X H (mm). (Example: Set the value of A to 50.) When the value of A is increased by 10, the image lead edge is shifted to the paper lead edge by 1mm. (Default: 50) 6) Set the lead edge void amount to B = 50 (2.5mm). When the value of B is increased by 10, the void amount is increased by about 1mm. For 25 or less, however, the void amount becomes zero. (Default: 50) (2) Image rear edge void amount adjustment 1) Set a scale to the rear edge section of A4 or 11 x 8 1/2 paper size as shown in the figure below, and cover it with B4 or 8 1/2 x 14 paper. 2) Execute SIM 50-01 to select the image rear edge void amount adjustment mode. The set adjustment value is displayed on the copy quantity dis- play. 3) Make a copy and measure the void amount of image rear edge.4) If the measurement value is out of the specified range, change the set value and repeat the adjustment procedure. The default value is 50. Note:The rear edge void cannot be checked with the first sheet after entering the simulation mode, the first sheet after turn- ing off/on the power, or the first sheet after inserting the cassette. Use the second or later sheet to check the rear edge void. (3) Center offset adjustment 1) Set the self-made test chart for the center position adjustment so that its center line is aligned with the center mark of the doc- ument guide. Test chart for the center position adjustment. Draw a line at the center of A4 or 8 1/2 x 11 paper in the paper transport direction. 2) Execute SIM 50-10 to select the print center offset (cassette paper feed) adjustment mode. The set adjustment value is displayed on the copy quantity dis- play. 3) Make a copy and check that the copied center line is properly positioned. The standard value is 0 ± 2mm from the paper center. 4) If the measured value is out of the specified range, change the set value and repeat the adjustment procedure. When the set value is increased by 1, the copy image is shifted by 0.1mm toward the rear frame. For the manual paper feed, change the manual paper feed adjustment mode and perform the similar procedures. Since the document center offset is automatically adjusted by the CCD which scan the reference lines (F/R) on the back of document guide, there is no need to adjust manually. 5mm 10mm (Example) Distance between paper lead edge and image: H = 5mm Image loss: R = 3mm B4 or 8 1/2″ × 14″ paper A4 size rear edge Paper rear edge Void amount (Standard value: 2 - 3mm) Scale image Document guide Center Copy paper (A4 or 8 1/2″ × 11″) (Copy A) (Copy B)2.0mm or less 2.0mm or less Copy image Copy paper folding line Copy image Copy paper folding line Shift Shift (Paper feed direction)
![](/img/blank.gif)
MX-B200 ADJUSTMENTS 9 - 4 2. Copy density adjustment A. Copy density adjustment timing The copy density adjustment must be performed in the following cases: When maintenance is performed. When the developing bias/grid bias voltage is adjusted. When the optical section is cleaned. When a part in the optical section is replaced. When the optical section is disassembled. When the OPC drum is replaced. When the main control PWB is replaced. When the EEPROM on the main control PWB is replaced. When the memory trouble (U2) occurs. B. Note for copy density adjustment 1) Arrangement before execution of the copy density adjustment Clean the optical section. Clean or replace the charger wire. Check that the voltage at the high voltage section and the devel- oping bias voltage are in the specified range. C. Necessary tool for copy density adjustment One of the following test charts: UKOG-0162FCZZ, UKOG-0089CSZZ, KODAK GRAY SCALE B4 (14 x 8 1/2) white paper The user program AE setting should be 3. Test chart comparison table D. Features of copy density adjustment For the copy density adjustment, the image data shift function pro- vided in the image process LSI is used. List of the adjustment modes E. Copy density adjustment procedure Use SIM 46-1 to set the copy density for each copy mode. For selection of modes, use the [Exposure mode selector] key. (1) Test chart (UKOG-0162FCZZ) setting 1) Place the test chart so that its edge is aligned with the A4 (Let- ter) reference line on the document table. Then place a A4 (14 x 8 1/2) white paper on the test chart and close the docu- ment cover. (2) Perform the adjustment in each mode. 1) Execute SIM 46-01 (300dpi). To adjust in 600dpi, execute SIM 46-02. 2) Select the mode to be adjusted with the exposure mode select key. Set the exposure level to 3 for all adjustment. (Except for the auto mode.) UKOG- 0162FCZZ DENSITY No.12345678910W UKOG- 0089CSZZ DENSITY No.0.1 0.2 0.3 0.5 1.9 0 KO DAK GRAY SCALE123419A Auto mode Brightness 1 step only Manual mode Brightness 5 steps. Adjustment of only the center brightness is made. Photo mode Brightness 5 steps. Adjustment of only the center brightness is made. Manual T/S mode Brightness 5 steps. Adjustment of only the center brightness is made. T/S Auto mode Brightness 1 step only 110W23456789 Adjustment modeExposure mode display lampSharp gray chart adjustment level Auto mode Auto lamp ON 3 is slightly copied. Manual mode Manual lamp ON 3 is slightly copied. Photo mode Photo lamp ON 3 is slightly copied. Manual T/S modeManual lamp/Photo lamp ON 3 is slightly copied. Auto T/S modeAuto lamp/Photo lamp ON 3 is slightly copied. Test chartWhite paper Exposure mode select key/display lamp [Exposure mode selector] key/ display lamp (1) (2) (1) (2)
![](/img/blank.gif)
MX-B200 ADJUSTMENTS 9 - 5 3) Make a copy. Check the adjustment level (shown in the above table) of the exposure test chart (Sharp Gray Scale). (When too bright):Decrease the value displayed on the copy quantity display. (When too dark):Increase the value displayed on the copy quan- tity display. * The value can be set in the range of 1 - 99. 3. High voltage adjustment A. Main charger (Grid bias) Note: Use a digital multi meter with internal resistance of 10MΩ or more measurement. After adjusting the grid LOW output, adjust the HIGH output. Do not reverse the sequence. Procedures 1) Set the digital multi meter range to DC700V. 2) Set the positive side of the test rod to the connector CN11-3 (GRID) of high voltage section of the power PWB and set the negative side to the frame ground (power frame). 3) Execute SIM 8-2. (The main charger output is supplied for 30 sec in the grid voltage HIGH output mode.) 4) Adjust the control volume (VRG1) so that the output voltage is 580 ± 12V. B. DV bias check Procedures 1) Set the digital multi meter range to DC500V. 2) Set the positive side of the test rod to the connector CN-10-1 (DV BIAS) and set the negative side to the frame ground (power frame). 3) Execute SIM 8-1 to output the developing bias for 30sec, and check that the output is –400 ± 8V. 4. SPF scan position automatic adjustment (Option) Place a A4 paper (white chart) so that it covers the SPF scan glass and the OC glass together, and close the SPF. When simulation 53-08 is executed, the current adjustment value is displayed as the initial display. * Default is 1. Adjustment range is 1 – 99. Adjustment unit 1 = about 0.127mm * If the values are kept as the default values, SPF scan is not per- formed properly. The front area of the proper scan position may be scanned. In case of AUTO, press [START] key, and the mirror unit scans from the home position to the SPF scan position with the adjust- ment value displayed. The SPF glass cover edge position is calcu- lated from the difference between the SPF glass cover edge and the OC side document glass CCD output level. If the adjustment is normal, the adjusted value is displayed. If abnormal, the error LED lights up with the current set value displayed. During the error LED is lighted, when [START] key is pressed again, execution is performed again. Sharp Gray Scale adjustment level Non toner save mode Toner save mode 110W23456789 Slightly copied. Not copied. 110W23456789 Slightly copied. Not copied. VRG1 Note: A digital multi meter with internal resistance of 1GΩ must be use for correct check. The adjustment volume is locked, and no adjustment can be made. ModeDisplay itemDefault LED SPF scan position auto adjustmentAUTO 1 AE mode lamp (Option) SPF scan position manual adjustmentMANU 1 TEXT mode lamp (Option) VRDV
![](/img/blank.gif)
MX-B200 ADJUSTMENTS 9 - 6 5. SPF mode sub scanning direction magnification ratio adjustment (Option) Note:Before performing this adjustment, be sure to check that the OC mode adjustment in copying has been completed. 1) Put a scale on the original table as shown below, and make a normal copy (100%) on the front and the back surfaces to make a test chart. Note:Since the printed copy is used as a test chart, put the scale in paralled with the edge lines. 2) Set the test chart on the SPF and make a copy in the normal ratio (100%). (Option) 3) Compare the scale image and the actual image. If necessary, perform the following adjustment procedures. 4) Execute SIM 48-05. 5) The current sub scanning direction magnification ratio correc- tion value is displayed in two digits on the display section. 6) Enter the set value and press the [START] key. * When there is no document in SPF, copy is inhibited. 6. Automatic black level correction a. Cases when the adjustment is required 1) When the main PWB is replaced. 2) When the EEPROM in the main PWB is replaced. 3) When U2 trouble occurs. 4) When repairing or replacing the optical section. b. Adjustment procedure Used to acquire the black level target value used for the black level adjustment of white balance. When SIM 63-02 is executed, the current correction value is dis- played in 3 digits of 12bit hexadecimal number. Place the gray gradation chart (UKOG-0162FCZZ) used as the correction document so that the density 10 (black side) comes on the left side and that the chart is upside down at the center of the plate left center. When START key is pressed, the mirror base unit scans the chart and calculates the correction value. After completion of correction, the corrected value is displayed on the display section. * Default: 0 * If the value is set to the default, operation is made with 0x60. Mode LED Default Sub scan magnification ratio adjustment on the surface of SPF documentAE mode lamp (Option)50 Adjustment mode Spec value SIM Set valueSetting range Sub scanning direction magnification ratio (SPF mode)At normal: ±1.0%48-5 Add 1: 0.1% increase Reduce 1: 0.1% decrease1 – 99 Chart back surface 10
![](/img/blank.gif)
MX-B200 SIMULATION, TROUBLE CODES 10 - 1 [10] SIMULATION, TROUBLE CODES 1. Entering the simulation mode To enter the serviceman simulation mode, press the keys as fol- lows: [Clear] key → Exposure mode selector key → [Clear] key → Exposure mode selector key 2. Key rule 3. List of simulations [] [] key:Entry of MAIN CODE/SUB CODE Setting of the adjustment values for the adjustment-related simulations When [%] key is pressed simultaneously, the value is displayed in the descending sequence such as [0] → [9], not as [0] → [1]. [START] key: Settlement [START] key: Settlement / Print [Clear] key:(Interrupting operation check) Returns to the upper hierarchy. On the initial display (00-00), it terminates the simulation. Exits from the simulation mode. For a simulation of adjustment, the display returns to the initial display (00-00). Sim No.Sub codeOperation 1 01 Mirror scan operation 02 Mirror home position sensor (MHPS) status display 06 Aging of mirror scanning 2 01 SPF aging operation (Option) 02 SPF sensor status display (Option) 03 SPF Motor ON (Option) 5 01 Operation panel display check 02 Fusing lamp, cooling fan operation check 03 Copy lamp ON 6 01 Paper feed solenoid ON 02 Resist solenoid ON 7 01 Warm-up display and aging with jam 06 Intermittent aging 08 Shift to copy with the warm-up display 8 01 Developing bias 02 Main charger (Grid high) 03 Grid voltage (Low) 06 Transfer charger 10 Toner motor aging 14 Cancel of troubles other than U2 16 Cancel of U2 trouble 20 01 Maintenance counter clear 21 01 Maintenance cycle setting 22 01 Maintenance counter display 02 Maintenance preset display 04 JAM total counter display 05 Total counter display 06 Developer counter display 08 SPF counter display (Option) 12 Drum counter display 13 CRUM type display 14 ROM version display 17 Copy counter display 18 Printer counter display 19 Scanner mode counter display 21 Scanner counter display 22 SPF JAM counter display (Option) 24 01 JAM total counter clear 04 SPF counter clear (Option) 06 Developer counter clear 07 Drum counter clear 08 Copy counter clear 09 Printer counter clear 13 Scanner counter clear 14 SPF JAM total counter clear (Option) 15 Scanner mode counter clear 25 01 Main motor operation check (Cooling fan motor rotation check) 10 Polygon motor ON 26 02 SPF setup (Option) 03 2nd cassette setup (Option) 06 Destination setup 07 Machine conditions check 20 Rear edge void setup 30 CE mark support control ON/OFF 37 Cancel of stop at developer life over 39 Memory capacity check 40 Polygon motor OFF time setup (Time required for turning OFF after completion of printing) 42 Transfer ON timing control setup 43 Side void setup 54 γ life correction setting 62 Energy-save mode copy lamp setup 69 Used to set the operating conditions for toner near end 30 01 Paper sensor status display 41 06 OC cover float detection level adjustment (Option) 07 OC cover float detection margin setting (Option) 43 01 Fusing temperature setting (Normal copy) 04 Fusing temperature setting in multi copy 09 Postcard size paper fusing control setting 11 Postcard size paper fusing temperature setting 14 Fusing start temperature setting 15 Postcard size paper fusing control cycle synchronization setting 46 01 Copy density adjustment (300dpi) 02 Copy density adjustment (600dpi) 18 Image contrast adjustment (300dpi) 19 Exposure mode setup (AE mode) 20 SPF exposure correction (Option) 29 Image contrast adjustment (600dpi) 30 AE limit adjustment 31 Image sharpness adjustment 32 Copier color reproduction setup 48 01 Front/rear (main scanning) direction and scan (sub scanning) direction magnification ratio adjustment 05 SPF mode sub scan direction magnification ratio in copying (Option) 49 01 Flash ROM program writing mode 50 01 Lead edge image position 06 Copy lead edge position adjustment (SPF) (Option) 10 Center offset adjustment 12 Document off-center adjustment 51 02 Resist quantity adjustment 53 08 SPF scan position automatic adjustment (Option) 61 03 Polygon motor check (HSYNC output check) 63 01 Shading check 02 Black level automatic correction 12 Light quantity stabilization wait time setting 13 Light quantity stabilization band setting 64 01 Self print Sim No.Sub codeOperation
![](/img/blank.gif)
MX-B200 SIMULATION, TROUBLE CODES 10 - 2 4. Descriptions of various simulations Main codeSub codeContents Details of function/operation 1 01 Mirror scan operation[Function] When [OK]/[START] key is pressed, the home position is checked and the mirror base performs full scan at the speed of the set magnification ratio. During operation, the set magnification ratio is displayed. The mirror home position sensor status is displayed with the Drum replacement required lamp . (When the mirror is in the home position, the lamp lights up.) During operation, the copy lamp lights up. When [Clear] key is pressed, if the operation is on the way, it is terminated and the machine goes to the sub code entry standby mode. [ZOOM UP/DOWN] key (ZOOM LED ON) or [Fixed magnification ratio select] key (Fixed magni- fication ratio LED ON) ∗When [ZOOM UP/DOWN] key is pressed, the magnification ratio is displayed for a certain period, and the display returns to the sub code display. ∗When [%] key is being pressed, the magnification ratio can be displayed. 02 Mirror home position sensor (MHPS) status display[Function] Monitors the mirror home position sensor, and makes the Drum replacement required lamp turn on during the sensor ON status. 06 Aging of mirror scanning[Function] When [START] key is pressed, the mirror base performs full scan at the speed of the set magni- fication ratio. During operation, the set magnification ratio is displayed. After 3sec, the mirror base performs full scan again. ∗When [START] key is pressed once, the ready lamp remains OFF. The mirror home position sensor status is displayed on the Drum replacement required lamp. (The lamp is ON when the mirror is in the home position.) During aging, the copy lamp is ON. [Operation] The operation is similar to simulation 1-01. 2 01 SPF aging operation (Option)[Function] When [START] key is pressed, the set magnification ratio is obtained. For the SPF, the single- face document transport is performed. However, the operating conditions dont matter and the operation is not stopped even in case of a jam. [Operation] The operation is similar to simulation 1-01. 02 SPF sensor status display (Option)[Function] The ON/OFF status of the SPF sensors can be checked with the LED. When a sensor is ON, the sensor name is displayed on the LED. 03 SPF Motor ON (Option)[Function] When [START] key is pressed, the motor rotates for 10sec at the speed corresponding to the set magnification ratio. [Operation] The operation is similar to simulation 1-01. Sensor Display item (Option) Document set sensor Toner cartridge replacement required lamp SPF document transport sensor Misfeed lamp
![](/img/blank.gif)
MX-B200 SIMULATION, TROUBLE CODES 10 - 3 5 01 Operation panel display check[Function] When [ENTER/START] key is pressed, the LED on the operation panel lights up in all pixels. The status display is as follows: After all ON (5 sec) 7seg panel model: Returns to the sub code input standby (Sub code blinking). During LED check mode (All ON) 7seg panel model: When [1 UNIT UP] key is pressed, the machine goes into the individual lighting mode. When [C] key is pressed, the machine enters the sub code input standby state (sub code blinking). When [START] key is pressed, the machine goes into the key input check mode. In the individual lighting mode, the LED on the operation panel moves from the top of the left edge to the bottom, then moves to the next right and from the top to the bottom. In this manner, all LED’s are lighted sequentially. (For the 7seg display, the LED’s of three digits are lighted at a time.) After completion of lighting all the LED’s, the machine returns to the all- lighting state. It enters the sub code input standby state 5 sec after returning to the all-lighting state. (The cycle of the individual lighting mode is: ON: 300ms, OFF: 20ms) The status display is as follows: 7seg display during the key input check mode 7seg panel model: --- Every time a key on the operation panel is pressed, the number of input is added to be displayed on the 7seg display. The key which was pressed once is not counted again. When [START] key is pressed, the count is added. The machine goes to the LED lighting check mode (LED all-lighting state) 3sec after that. 02 Fusing lamp, cooling fan operation check[Function] When [OK]/[START] key is pressed, the fusing lamp repeats ON for 500ms and OFF for 500ms 5 times. During this period, the cooling fan motor rotates. 03 Copy lamp ON[Function] When [START] key is pressed, the copy lamp turns ON for 5sec. 6 01 Paper feed solenoid ON[Function] When [START] key is pressed, the selected paper feed solenoid repeats ON for 500ms and OFF for 500ms 20times. 02 Resist solenoid ON[Function] When [START] key is pressed, the resist solenoid repeats ON for 500ms and OFF for 500ms 20 times. 7 01 Warm-up display and aging with jam[Function] Copying is repeated to make the set quantity of copies. When the simulation is executed, warm-up is started and warm-up time is added for every sec- ond from 0 and displayed. When warm-up is completed, addition is stopped. When [Clear] key is pressed, the ready lamp lights up. After that, enter the copy quantity with [ ] [ ] key and press [START] key to repeat copying of the set quantity (interval 0sec). To cancel the simulation, turn off the power or execute a simulation which causes hardware reset. 06 Intermittent aging[Function] Copying is repeated to make the set quantity of copies. When the simulation is executed, warm-up is performed and the ready lamp is lighted. Enter the copy quantity with the [ ] [ ] key and press [START] key, and copying is executed to make the set quantity of copies, and the ready state is kept for 3sec, and copying is executed again to make the set quantity of copies. These operations are repeated. To cancel the simulation, turn off the power or execute a simulation which executes hardware reset. 08 Shift to copy with the warm-up display[Function] Enter the simulation code, and warm-up is started and warm-up time is counted for every sec- ond from 0 and displayed. When [Clear] key is pressed during counting up, 0 is displayed on the display and counting is stopped. However, warm-up is continued. After completion of warm-up, counting is terminated. (The aging function is removed from simu- lation 7-01.) Main codeSub codeContents Details of function/operation