Sharp Mx 2300n Service Manual
Here you can view all the pages of manual Sharp Mx 2300n Service Manual. The Sharp manuals for Printer are available online for free. You can easily download all the documents as PDF.
Page 151
MX-2300/2700 N/G SIMULATION 7 – 45 43 43-1 Purpose: Setting Function (Purpose): Used to set the fusing temperature in each operation mode. Section:Fusing Item: Operation Operation/Procedure 1) Select the set item with [↑] and [↓] buttons. The highlighted set value is switched and the value is dis- played in the setting area. * If there is any item over [↑], an active display is made and item is shifted. If there is no item over [↑], the display grays out and the operation is invalid. If there is...
Page 152
MX-2300/2700 N/G SIMULATION 7 – 46 *1: Japan, China, AB-B *2: U.S.A, Canada, Europe, U.K, Australia, Inch, AB_A 43-20 Purpose: Setting Function (Purpose): Used to correct the environments of low temperature and low humidity (L/L) for the fusing temperature setting 1 for each paper (SIM 43-01). Section:Fusing Item: Operation Operation/Procedure 1) When the machine enters Simulation 43-20, the screen on the right is displayed. (The current set value is displayed.) 2) Select the set item with [↑] and...
Page 153
MX-2300/2700 N/G SIMULATION 7 – 47 43-21 Purpose: Setting Function (Purpose): Used to perform correction of high temper- ature and high humidity (H/H) environment for the fusing temperature setting 1 (SIM 43-01) for each paper. Section:Fusing Item: Operation Operation/Procedure 1) When the machine enters SIM 43-21, the following screen is displayed. (The current set value is displayed.) 2) Select the set item with [↑] and [↓] buttons.The highlighted section of the set value is switched and dis-...
Page 154
MX-2300/2700 N/G SIMULATION 7 – 48 * WARMUP END TIME HH → 1s change by 1 count The other correction values → 1°C change by 1 count 43-22 Purpose:Setting Function (Purpose): Used to perform L/L (low temperature, low humidity) correction for the fusing tempera- ture setting 1 (SIM 43-04) for each paper. Section:Fusing Item: Operation Operation/Procedure 1) When the machine enters Simulation 43-22, the following screen is displayed. (The current set value is displayed.) 2) Select the set item with [↑]...
Page 155
MX-2300/2700 N/G SIMULATION 7 – 49 * PLAIN BW DUPCNT LL, PLAIN CL DUPCNT LL, HEAVY BW DUP APCNT LL, HEAVY CL DUP APCNT LL → 1s change by 1 count The other correction values → 1°C change by 1 count 43-23 Purpose: Setting Function (Purpose): Used to perform H/H (high temperature, high humidity) correction for the fusing tem- perature setting 1 (SIM 43-04) for each paper. Section:Fusing Item: Operation Operation/Procedure 1) When the machine enters Simulation 43-23, the following screen is displayed....
Page 156
MX-2300/2700 N/G SIMULATION 7 – 50 43-24 Purpose: Setting Function (Purpose): Used to enter the correction values for SIM 43-1 and SIM 43-4 temperature correc- tions. Section:Fusing Item: Operation Operation/Procedure 1) Select the set item with [↑] and [↓] buttons. The highlighted section of the set value is switched and dis- played on the set setting area. * If there is any item over [↑], an active display is made and item is shifted. If there is no item over [↑], the display grays out and the...
Page 157
MX-2300/2700 N/G SIMULATION 7 – 51 44 44-1 Purpose: Setting Function (Purpose): Used to set whether the correction func- tions of the image forming (process) sec- tion are enabled or not. Section:— Item:— Operation/Procedure 1) When the machine enters Simulation 44-01, the currently set button is highlighted. Set the item to be set to the normal display. (Two or more items can be selected.) When an item is selected, its button is highlighted. When the highlighted button is pressed again, it returns...
Page 158
MX-2300/2700 N/G SIMULATION 7 – 52 1) Adjust so that the LED light emitting quantity of BK/CL is the target value ± 2. * Target value BK: Item B of SIM 44-04 CL: Item A of SIM 44-13 2) After completion of the adjustment, check the belt surface con- dition with the BK sensor. 44-4 Purpose:Setting Function (Purpose): Used to perform the correction operation of the image forming section and to set the process control sensor adjustment condi- tions. Section: Process Item: Operation...
Page 159
MX-2300/2700 N/G SIMULATION 7 – 53 3) When [OK] button is pressed, the current set value is saved to EEPROM and RAM. * When [↑], [↓], [COLOR], or [BLACK] key is pressed, the cur- rent set value is saved to EEPROM and RAM. 44-6 Purpose: Operation test/Check Function (Purpose): Used to forcibly execute the correction in the image process section (high-density process correction) (process correction). Section:Process Item: Operation Operation/Procedure 1) When the machine enters SIM 44-06, the screen...
Page 160
MX-2300/2700 N/G SIMULATION 7 – 54 [OTHER] button: Display of environment area, membrane decrease correction steps and process control execution counter, and model type. * When [CLOSE] button is pressed, the display shifts to the copy basic screen of simulation. * Copying can be performed also by pressing [COLOR]/[BLACK] key. Mode Page number Display item (*: correction value) Content description Display rangeDefault value CPY/PRN 1/2 P (PROCON) Left BLACK : GB ***/*** DV ***/*** High density process...