Page 11

EN-9
ENGLISH
hook
screw
INSTALL	POWER	CORD	HOOK	
•	Attach	the	hooks	to	the	back	of	air	conditioner	with	the	screws.
•	When	storing	or	moving	the	unit,	wind	the	power	cord	around	the	hooks.  

Page 12

EN-10
AB
ABC E
D
A
B
INSTALL DRAINAGE HOSE 
Drainage
1 
Remove drain cap from drain port.
2 Attach the drain hose clamp to the back panel of the air conditioner nea\
r the drain port with the screw.
A.	Drain	capB.	Drain	portA.	Drain	portB.	Drain	hose	clamp
A. Rubber plugB.	Drain	portC.	Drain	hose
D.	Drain	hose	clipE.	Drain	hose	clamp
3 Attach one end of the drain hose to the drain port with the clip.
4 Insert the rubber plug into the other end of the drain hose and secure with clip. 

Page 13

EN-11
ENGLISH
A.	Drain	portB.	Drain	hose	clamp
When	COOL	or	DRY	(DEHUMIDIFICATION)	is	running,	condensation	will	drain	to	water	tank.	When	water	tank	is	filled,	Buzzer	will	sound	8	times,	LED	window	show	error code "H8".  
In this case, plug out drain hose from fixing clamp,unsecure the clip, pull out the rubber plug from the drain hose, then drain out water in tank.  Then reinstall the drainage hose.
The unit will resume running after compressor stops for 3 minutes.
AB  

Page 14

EN-12
INSTALL WINDOW PANEL
Installation in a double-hung sash window
Hole
Projec-tion
Insect guard netRain guard
"A"
"A"
Foam seal A (adhesive	type)
22"-24"
Window	panel
Window	sill
1 Connect the rain guards to the insect 
guard net.
  Insert all three projections on each rain guard into the holes in the insect guard net. 
	 Side	 “A”	will	now	 be	at	 the	 top,	 as	indicated	in the diagram.
2 Attach the guard combined above to 
the window panel. 
  Push the insect guard net firmly...

Page 15

EN-13
ENGLISH
If the inner width of the window is between24"(609mm)	and	36.8"(934mm)	inclusive. 
(1)	 Open	the 	window 	sash 	and 	place 	the window panel on the window sill. 
(2)	 Slide 	the	 adjustment	 panel	to	fit	the	window frame width.
(3)	 Secure	 the	window	 panel	to	the	 sill	with 3 screws.
If the inner width of the window is between36.8"(934mm) 	and	48"(1219mm) 	inclusive.
(1)	 Attach	the 	extension	panel	to	the	adjustment panel.
(2)		 Open 	the 	window 	sash 	and 	place 	the...

Page 16

EN-14
INSTALL WINDOW PANEL
Installation in a sliding sash window
1 Connect the rain guards to the insect guard net.
  Insert all three projections on each rain guard into the holes in the insect guard net.	 Side	“A”	will	now	be	at	the	top,	as	indicated 	in the diagram.  
2 Attach the guard combined above to 
the window panel. 
  Push the insect guard net firmly to ensure that its four projections fit into the holes in the window panel.	 Side	“A”	will	now	be	at	the	top,	as	indicated 	in the diagram, when...

Page 17

EN-15
ENGLISH
If the inner width of the window is between24"(609mm)	and	36.8"(934mm)	inclusive. 
(1)	 Open	the	window	 sash	and	place	 the	window panel on the window sill. 
(2)	 Slide 	the	 adjustment	 panel	to	fit	the	window frame width.
(3)	 Secure 	the 	window 	panel 	to 	the 	sill 	with 3 screws.
If the inner width of the window is between36.8"(934mm) 	and	48"(1219mm) 	inclusive.
(1)	 Attach	the 	extension	panel	to	the	adjustment panel.
(2)		 Open	 the	window	 sash	and	place	 the...

Page 18

EN-16
Exhaust hose
Window exhaust adapter A
Window exhaust 
adapterInstallation of the exhaust hose
1  Attach the window exhaust adapter B and C to the exhaust 
hose.
  Extend both ends of the exhaust hose and insert them into the window ex-haust adapter A respectively, and turn them until they stop. Make sure they are securely attached.
2 Attach the window exhaust adapter A to the unit.
 Insert the two projections on the win-dow exhaust adapter A into the two holes on the unit, and firmly attach them to...

Page 19

EN-17
ENGLISH
Removal of the exhaust hose
1 Remove the exhaust  hose from the window exhaust adapter.
2 Remove the window exhaust adapter A from the unit.
  Lift up and remove the window exhaust adapter A from the unit by pushing down on the two projections.
1 2
Exhaust hose
window exhaust     
adapter  

Page 20

EN-18
CONTROL PANEL DISPLAY & OPERATING INSTRUCTIONS
CONTROL PANEL & DISPLAY
OPERATING INSTRUCTIONSWhen	pressing 	key,	buzzer	makes 	a	sound, 	indicator 	lamp	shows	relevant 	
state for 2 seconds.
1.  ON/OFF Button  Press the button once to manually turn the unit on. Press once more to turn the unit off.
2.  "+" , "-" Button In	COOL	mode, 	press	"-"	once,	 the	set	temperature	will	 decrease	1º	C(	F)	 ,	press	"+" 	once,	the	set	temperature	will	 increase	1ºC	(	F). 	The 	set...
Start reading Sharp Cv10ctxb Manual

Related Manuals for Sharp Cv10ctxb Manual

All Sharp manuals