    							EN-9
    ENGLISH
    hook
    screw
    INSTALL	POWER	CORD	HOOK	
    •	Attach	the	hooks	to	the	back	of	air	conditioner	with	the	screws.
    •	When	storing	or	moving	the	unit,	wind	the	power	cord	around	the	hooks.  
    						
    							EN-10
    AB
    ABC E
    D
    A
    B
    INSTALL DRAINAGE HOSE 
    Drainage
    1 
    Remove drain cap from drain port.
    2 Attach the drain hose clamp to the back panel of the air conditioner nea\
    r the drain port with the screw.
    A.	Drain	capB.	Drain	portA.	Drain	portB.	Drain	hose	clamp
    A. Rubber plugB.	Drain	portC.	Drain	hose
    D.	Drain	hose	clipE.	Drain	hose	clamp
    3 Attach one end of the drain hose to the drain port with the clip.
    4 Insert the rubber plug into the other end of the drain hose and secure with clip. 
    						
    							EN-11
    ENGLISH
    A.	Drain	portB.	Drain	hose	clamp
    When	COOL	or	DRY	(DEHUMIDIFICATION)	is	running,	condensation	will	drain	to	water	tank.	When	water	tank	is	filled,	Buzzer	will	sound	8	times,	LED	window	show	error code "H8".  
    In this case, plug out drain hose from fixing clamp,unsecure the clip, pull out the rubber plug from the drain hose, then drain out water in tank.  Then reinstall the drainage hose.
    The unit will resume running after compressor stops for 3 minutes.
    AB  
    						
    							EN-12
    INSTALL WINDOW PANEL
    Installation in a double-hung sash window
    Hole
    Projec-tion
    Insect guard netRain guard
    "A"
    "A"
    Foam seal A (adhesive	type)
    22"-24"
    Window	panel
    Window	sill
    1 Connect the rain guards to the insect 
    guard net.
      Insert all three projections on each rain guard into the holes in the insect guard net. 
    	 Side	 “A”	will	now	 be	at	 the	 top,	 as	indicated	in the diagram.
    2 Attach the guard combined above to 
    the window panel. 
      Push the insect guard net firmly to ensure that its four projections fit into the holes in the window panel.
     Side 	“A”	 will	now	 be	at	the	 top,	 as	indicated	in the diagram.
    3 Cut the foam seal A to the proper length and attach it to the window 
    sill.
    4 Attach the window panel to the 
    window sill. 
    If the inner width of the window is between22"(559mm)	and 	24"(609mm)	inclusive
     The window panel cannot be installed in windows 	less 	than 	22" 	(559mm) 	wide, 	as 	you will be unable to shut the exhaust cover.
    (1)	 Remove 	the 	adjustment 	panel 	from 	the window panel, and cut the window panel to the same width as the window. 
    (2)		 Open 	the 	window 	sash 	and 	place 	the 	window panel on the window sill.  
    (3)		 Secure	 the	window	 panel	to	the	 window	sill with 2 screws.
    CutWindow panel
    Adjustment panel
    Exhaust cover
    Panel de ventana
    Saliente 
    						
    							EN-13
    ENGLISH
    If the inner width of the window is between24"(609mm)	and	36.8"(934mm)	inclusive. 
    (1)	 Open	the 	window 	sash 	and 	place 	the window panel on the window sill. 
    (2)	 Slide 	the	 adjustment	 panel	to	fit	the	window frame width.
    (3)	 Secure	 the	window	 panel	to	the	 sill	with 3 screws.
    If the inner width of the window is between36.8"(934mm) 	and	48"(1219mm) 	inclusive.
    (1)	 Attach	the 	extension	panel	to	the	adjustment panel.
    (2)		 Open 	the 	window 	sash 	and 	place 	the  window panel on the window sill. 
    (3)		 Slide 	the	 adjustment 	and	 extension	panels to fit the window frame width.
    (4)	 Secure	 the	window	 panel	to	the	 win-dow  sill with 4 screws.
    5 Cut the foam seal (adhesive type) A and B to the proper length and attach it to the window panel.
    Attach foam seal A to the window panel and extension panel, and attach foam seal B to the adjustment panel.
    6 Close the window sash securely against the Window panel.  
    7  Cut the foam seal to an appropri-ate length and seal the opening between the top of the inner win-dow sash and the outer window sash.
    8	 Attach	the	bracket	with	a	screw.
    Extension panel
    24"-36.8"
    36.8" - 48"
    Foam	seal	A	(adhesive	type)
    Bracket  
    						
    							EN-14
    INSTALL WINDOW PANEL
    Installation in a sliding sash window
    1 Connect the rain guards to the insect guard net.
      Insert all three projections on each rain guard into the holes in the insect guard net.	 Side	“A”	will	now	be	at	the	top,	as	indicated 	in the diagram.  
    2 Attach the guard combined above to 
    the window panel. 
      Push the insect guard net firmly to ensure that its four projections fit into the holes in the window panel.	 Side	“A”	will	now	be	at	the	top,	as	indicated 	in the diagram, when it is installed in the window. 
    3 Cut the foam seal A (adhesive type) to the proper length and attach it to 
    the window frame.
    4 Install the window panel into the win-dow frame.
     Make sure that the exhaust cover is 
    attached to the window panel.
    If the inner width of the window is between22"(559mm)	and 	24"(609mm)	inclusive      
    The window panel cannot be installed in windows	less 	than 	21.3" 	(540mm) 	high, 	as you will be unable to shut the exhaust cover.
    (1)	 Remove 	the 	adjustment 	panel 	from 	the window panel, and cut the window panel to the same width as the window. 
    (2)		 Open 	the 	window 	sash 	and 	place 	the 	window panel on the window sill.  
    (3)		 Secure	 the	window	 panel	to	the	 window	sill with 2 screws.
    Hole
    Projection
    Insect guard net
    Rain guard
    "A"
    Projection
    "A"
    22"-24"
    Foam seal A
    Window	panel
    CutWindow panel
    Window panel
    Adjustment panel
    Exhaust cover 
    						
    							EN-15
    ENGLISH
    If the inner width of the window is between24"(609mm)	and	36.8"(934mm)	inclusive. 
    (1)	 Open	the	window	 sash	and	place	 the	window panel on the window sill. 
    (2)	 Slide 	the	 adjustment	 panel	to	fit	the	window frame width.
    (3)	 Secure 	the 	window 	panel 	to 	the 	sill 	with 3 screws.
    If the inner width of the window is between36.8"(934mm) 	and	48"(1219mm) 	inclusive.
    (1)	 Attach	the 	extension	panel	to	the	adjustment panel.
    (2)		 Open	 the	window	 sash	and	place	 the		window panel on the window sill. 
    (3)		 Slide 	the 	adjustment 	and 	extension 	panels to fit the window frame width.
    (4)	 Secure	 the	window	 panel	to	the	 win-dow  sill with 4 screws.     
    5 Cut the foam seal (adhesive type) A and B to the proper length and at-tach it to the window panel.
    Attach foam seal A to the window panel and extension panel, and attach foam seal B to the adjustment panel.
    6  Close the window sash securely against the Window panel.  
    7  Cut the foam seal to an appropriate length and seal the opening between the side of the inner window sash and the outer window sash.
    8	 Attach	the	bracket	with	a	screw.
    Adjustment panel
    Extension panel
    24"- 36.8"
    36.8"- 48"
    Foam seal A (adhesive	type)
    Bracket  
    						
    							EN-16
    Exhaust hose
    Window exhaust adapter A
    Window exhaust 
    adapterInstallation of the exhaust hose
    1  Attach the window exhaust adapter B and C to the exhaust 
    hose.
      Extend both ends of the exhaust hose and insert them into the window ex-haust adapter A respectively, and turn them until they stop. Make sure they are securely attached.
    2 Attach the window exhaust adapter A to the unit.
     Insert the two projections on the win-dow exhaust adapter A into the two holes on the unit, and firmly attach them to each other. 
    3 Attach the exhaust hose.
      Insert the exhaust hose to the window exhaust adapter in the window panel and turn it to lock it in place.
    The exhaust hose should be as short as possible for operational efficiency;	 however,	it	must	 not	be	twisted 	or	bent.	
    UnacceptableAcceptableAcceptable
    1
    2
    INSTALLATION AND REMOVAL OF EXHAUST HOSE 
    Window exhaust 
    adapter 
    						
    							EN-17
    ENGLISH
    Removal of the exhaust hose
    1 Remove the exhaust  hose from the window exhaust adapter.
    2 Remove the window exhaust adapter A from the unit.
      Lift up and remove the window exhaust adapter A from the unit by pushing down on the two projections.
    1 2
    Exhaust hose
    window exhaust     
    adapter  
    						
    							EN-18
    CONTROL PANEL DISPLAY & OPERATING INSTRUCTIONS
    CONTROL PANEL & DISPLAY
    OPERATING INSTRUCTIONSWhen	pressing 	key,	buzzer	makes 	a	sound, 	indicator 	lamp	shows	relevant 	
    state for 2 seconds.
    1.  ON/OFF Button  Press the button once to manually turn the unit on. Press once more to turn the unit off.
    2.  "+" , "-" Button In	COOL	mode, 	press	"-"	once,	 the	set	temperature	will	 decrease	1º	C(	F)	 ,	press	"+" 	once,	the	set	temperature	will	 increase	1ºC	(	F). 	The 	set	temperature	 range	from	16º	C	to	 30º	 C	(61º	F	 to	86º 	F).
    3.	 MODE 	Button Press	MODE	Button	repeatedly	to	 cycle	between	 the	modes: 	Cooling,	Dry 	(Dehumidifica-tion),	and	Fan	only	 mode.	 Each	press	 of	the 	MODE	button	 will	light	up	a	different	 lamp	on	the	control panel. The exhaust hose and window kit must be installed when the unit is in Cool or Dehumidification 	mode.	When	using	 the	unit	as	a	fan,	it	 is	unnecessary	to	 keep	the	exhaust	hose and window kit connected to the unit.
    4.  Fan Speed Button When 	the	unit	 is	running	 in	Cool	or	Fan 	mode, 	press	the	Fan	 Speed	 Button	to	select 	the	fan	speed in High, Middle, Low, Auto.
    5.  Water Full When 	COOL	or	 DRY	(Dehumidification)	 is	running,	condensation 	will	drain	 to	the 	water 	tank.	When	water 	tank	is	 full.	buzzer 	will	sound	8 	times,	and 	LED	screen 	will	show 	error	code	 ‘H8’.	In this case, drain out water tank.
    6.  Louver Direction This	unit	has 	4-Way	directional	 louvers.	Use	the	louver guides to direct air where cooling or fanning is needed 	most.	Hold	the	louver 	and	adjust	the 	air	flow 	direction, as show in the right diagram.
    Hold this hand grip to adjust the
    direction of Horizontal Louvers Hold this hand grip to adjust the
    direction of Vertical Louvers 
    Receiver window
    LED window
    DRY 
    mode lamp
    Temperature selection button
    COOL mode lamp
    MODE button
    FAN mode lamp
    FAN Speed lamp               ON/OFF button
    Fan speed button 
    						