Home > Sharp > Air Conditioner > Sharp Cv10ctxb Manual

Sharp Cv10ctxb Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Sharp Cv10ctxb Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 615 Sharp manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							CV10CTXB
    CV10CTXW
    CV10CTXS
    ENGLISH
    ESPA
    ÑOL
    PORTABLE TYPEROOM AIR CONDITIONER
    INSTALLATION AND  OPERATION MANUAL
    ACONDICIONADOR DE AIREPARA HABITACIÓN TIPO PORTÁTIL
    MANUAL DE INSTALACIÓN Y FUNCIONAMIENTO 
    						
    							EN-1
    ENGLISH
    Please read this manual carefully before using the product. This manual should be kept in a safe place for handy reference.
    Declaration of Conformity
    SHARP ROOM AIR CONDITIONER CV10CTXB, CV10CTXW, CV10CTXSThis device complies with Part 18 of FCC rules.
    Responsible Party:
    SHARP ELECTRONICS CORPORATION.Sharp Plaza, Mahwah, New Jersey 07495-1163TEL: 1-800-BE-SHARP
    ENGLISH
    CONTENTS
    	•	FOR	CUSTOMER	ASSISTANCE	 .........................................................EN-2
    	•	CONSUMER	LIMITED	WARRANTY	 ....................................................EN-3
    	•	PRECAUTIONS	 ........................................................................\
    ...........EN-4
    	•	LOCATION	 ........................................................................\
    ..................EN-7
    	•	INCLUDED	 ........................................................................\
    ..................EN-7
    	•	PART	NAMES	 ........................................................................\
    ..............EN-8
    	•	INSTALL	WINDOW	PANEL	 ..................................................................EN-12
    	•	INSTALLATION	AND	REMOVAL	OF	EXHAUST	HOSE	 ........................EN-16
     
    USE FOR AIR CONDITIONER
    	•	COOL	MODE	 ........................................................................\
    ..............EN-18
    	•	DRY	(DEHUMIDIFICATION)	MODE	 .....................................................EN-18
    	•	FAN	MODE	 ........................................................................\
    ..................EN-18
    	•	TO	CHANGE	AIR	FLOW	DIRECTION	 .................................................EN-18
    	•	TIMER	OPERATION	 ........................................................................\
    ....EN-21
    	•	SLEEP	OPERATION	 ........................................................................\
    ....EN-22
    	•	MAINTENANCE	 ........................................................................\
    ...........EN-23
    	•	BEFORE	CALLING	FOR	SERVICE	 ......................................................EN-25  
    						
    							EN-2
    To aid in answering questions if you call for service or for reporting loss or theft, please record below the model and serial number located on the back side of the unit.
    MODEL NUMBER 
    SERIAL NUMBER 
    DATE OF PURCHASE 
    Dealer Name 
    Address 
    City 
    State 
    Zip 
    Telephone 
    TO PHONE: Dial	1-800-BE-SHARP	(237-4277)	for:
    	SERVICE	(for	your	nearest	Sharp	Authorized	Servicer)	PARTS	(for	your	Authorized	Parts	Distributor) ACCESSORIES	ADDITIONAL	CUSTOMER	INFORMATION
    TO WRITE:  For service problems, warranty information, missing  items and other assistance:
     Sharp Electronics Corporation Customer Assistance Center	1300	Naperville	Drive Romeoville, IL 60446-1091
    TO ACCESS THE INTERNET: www.sharpusa.com
    Please provide the following information when you write or call: model number, serial number, date of purchase, your complete mailing address (including	zip	code),	your	daytime	telephone	number	(including	area	code)	and description of the problem.
    FOR CUSTOMER ASSISTANCE (the United States) 
    						
    							EN-3
    ENGLISH
    TO	OBTAIN	 SUPPLY,	 ACCESSORY	 OR	PRODUCT	 INFORMATION,	 CALL	1-800-BE-SHARP,	 OR	VISIT	 OUR	WEBSITE	AT	www.sharpusa.com
    SHARP ELECTRONICS CORPORATIONSharp Plaza, Mahwah, New Jersey 07495-1163
    CONSUMER LIMITED WARRANTY FOR THE U.S. USERS
    SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that  this Sharp brand product	 (the	“Product”),	 when	shipped	 in	its	 original	 container,	 will	be	free	 from	 defective	 workmanship	and  materials, and agrees that it will, at its option, either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to the purchaser for parts or	labor	for	the	period(s)	set	forth	below.
    This warranty does not apply to any appearance items of the Product nor to the additional excluded item(s)	set	forth	 below	 nor	to	any	 Product	 the	exterior	 of	which	 has	been	 damaged	 or	defaced,	 which	has	been subjected to improper voltage or other misuse, abnormal service or handling, or which has\
     been altered or modified in design or construction. 
    In order to enforce the rights under this limited warranty, the purchaser should  follow the steps set forth below and provide proof of purchase to the servicer. 
    The limited warranty described herein is in addition to whatever implied warranties may be granted to purchasers	by	law.	ALL	IMPLIED		WARRANTIES	INCLUDING	THE	WARRANTIES	OF	MERCHANTABILITY 	AND	FITNESS 	FOR 	USE 	ARE 	LIMITED 	TO 	THE 	PERIOD(S) 	FROM 	THE 	DATE 	OF 	PURCHASE 	SET 	FORTH 	BELOW. 	Some 	states 	do 	not 	allow 	limitations 	on 	how 	long 	an 	implied 	warranty 	lasts, 	so 	the 	above limitation may not apply to you. 
    Neither the sales personnel of the seller nor any other person is authorized to make any warranties other than those described herein, or to extend the duration of any warranties beyond the time period \
    described herein on behalf of Sharp. 
    The warranties described herein shall be the sole and exclusive warranties granted by Sharp and shal\
    l be the sole and exclusive remedy available to the purchaser. Correction of defects, in the manner and for the period of time described herein, shall constitute complete fulfillment of all liabilities and responsibilities of Sharp to the purchaser with respect to the Product, and shall constitute full satisfaction of all claims, whether based on contract, negligence, strict liability or otherwise. In no event shall Sharp be liable, or in any way responsible, for any damages or defects in the Product which were caused by repairs or attempted repairs performed by anyone other than an authorized servicer. Nor shall Sharp be liable or in any way responsible for any incidental or consequential economic or property damage. Some states do not allow the exclusion of incidental or consequential damages, so the a\
    bove exclusion may not apply to you. 
    THIS 	WARRANTY 	GIVES 	YOU 	SPECIFlC 	LEGAL 	RIGHTS. 	YOU 	MAY 	ALSO 	HAVE 	OTHER 	RIGHTS 	WHICH	VARY	FROM	STATE	TO	STATE.	
    CV10CTXB,	CV10CTXW,	CV10CTXSPortable Air Conditioner. Be sure to have this information available when you need service for your Product. 
    One	(1)	year	parts	and	labor	from	date	of	purchase.	The	warranty	period	continues	for	a	total	of	five	(5)	years	from	date	of	purchase	for	the	Sealed Cooling System parts; labor and service are not provided free of change for this additional period.
    Appearance items of the Product, filters, or accessories, or any printed materials. Product which has been used for rental and/or commercial purposes.
    From	a	Sharp	 Authorized	 Servicer	located	in	the	 United	 States.	 To	find	the location of the nearest Sharp Authorized Servicer, call Sharp Toll Free at 1-800-BE-SHARP. 
    Contact your Sharp Authorized Servicer to obtain in-home service for this Product. The Servicer will come to your home, and if it is necessary to remove the Product, the Servicer will reinstall it. Be sure to have Proof of Purchase available. 
    CONSUMER LIMITED WARRANTY
    Your Product Model Number & Description:
    Warranty Period for this Product: 
    Additional Item(s) Excluded From Warranty Coverage (If any): 
    Where to Obtain Service:
    What to Do to Obtain Service:   
    						
    							EN-4
    Points to keep in mind when using your unit.
    WARNINGS FOR USE
    •	Install	the	unit	 in	accordance	 with	the	installation	 instructions	 in	the	 latter	 section	of this manual.
    •	Do	not	modify	any	part	of	this	product.	
    •	Do	not	insert	anything	into	any	part	of	the	unit.	
    •	Ensure	the	power	supply	used	has	an	appropriate	voltage	rating.	 Only	 use	a	three-pin	 grounded	 electrical	AC	socket	 rated	125V,	 60Hz,	 and	15	amps	 or	more. 	 Use	of	a	power	 supply	 with	an	improper	 voltage	rating	can	result	 in	damage	 to	the	 unit	and possibly fire.
    •	Always	use	a	fuse	with	the	proper	amp	rating.			 Do	 not,	under	 any	circumstances,	 use	wire,	 pins	or	other	 objects	 in	place	 of	a	proper	fuse.
    •	In	 the	 event	 of	any	 abnormality	 with	the	unit	 (ex.	a	burning	 smell),	turn	it	off	 imme-diately and disconnect the power supply.
    WARNING FOR POWER SUPPLY CORD
    •	This	unit	uses	a	plug	with	a	built-in	fuse.		 Read the precautions on the plug before using the unit.
    •	Always	 conduct	a	“Power	 Plug	Check”	 before	use	to	confirm	 the	power	 plug	func-tions normally.
    •	This	 power	 plug	must	 only	be	plugged	 into	an	appropriate	 wall	socket.	 Do	not	 use	in conjunction with any extension cords.
    •	Push	the	power	plug	securely	into	the	socket	and	make	sure	it	is	not	loose.
    •	Do	not	pull,	deform,	or	modify	the	power	supply	cord,	or	immerse	it	in	water.	 Pulling or misuse of the power supply cord can result in damage to the unit and cause electrical shock.
    •	A	 damaged	 power	supply	 cord	must	 be	replaced	 with	a	new	 power	 supply	 cord	obtained from the product manufacturer and not repaired.  Replacement must be performed by manufacture's service agent in order to avoid a hazard.
    Radio or TV Interference
    If this room air conditioner should cause interference to radio or television reception, try to correct the interference by one or more of the following measures:
    •	Reorient	or	relocate	the	receiving	antenna.
    •	Increase	the	separation	between	the	room	air	conditioner	and	radio/TV	receiver.
    •	Connect	 the	room	 air	conditioner	 into	an	outlet	 on	a	circuit	 different	 from	that	to	which	the	radio/TV	receiver	is	connected.
    •	Consult	the	dealer	or	an	experienced	radio/TV	technician	for	help.
    PRECAUTIONS  
    						
    							EN-5
    ENGLISH
    USAGE CAUTIONS
    •	Be	sure	 to	turn	 the	unit	 off	and	 disconnect	 the	power	 supply	 cord	before	 perform-ing any maintenance or cleaning.  
    •	Do	not	splash	or	pour	water	directly	onto	the	unit.			 Water	can	cause	electrical	shock	or	equipment	damage.
    •	Drainage	should	be	performed	whenever	moving	the	unit.	 If any water remains in the tank, it may spill out while being moved.
    •	Remove	the	window	panel	in	the	event	of	particularly	adverse	weather. Extremely adverse weather may cause water to leak in through the openings.
    •	To	 ensure	 proper	drainage,	 the	drainage	 hose	must	 have	no	kinks	 or	be	 on	 a	differ-ent	level	during	dehumidification	mode. The drained water may spill out into the room.
    •	The	 temperature	 around	the	drainage	 hose	must	 not	be	below	 freezing	 point	when	used.	 Drained	 water	may	freeze	 inside	the	hose,	 causing	 water	inside	 the	unit	 to	overflow	 into	the room.
    •	Do	not	block	the	exhaust	air	outlet	with	obstacles. Cooling performance may be reduced or stop completely.
    WARNING ABOUT GROUNDING
    •	Improper	 use	of	the	 grounding	 plug	can	result	in	the	risk	of	electric	shock.	 This appliance must be grounded. In the event of an electrical short circuit, ground-ing reduces the risk of an electric shock by providing a less resistant conduit for the electric current.  This appliance is equipped with a cord that has a grounding wire connected to a grounding plug. The plug must be plugged into a socket that is properly installed and grounded. 
    •	Do	 not	under	 any	circumstances	 cut	or	remove the round grounding pin from this plug. Consult a qualified electrician or service-man if the grounding instructions are not completely understood, or if in any doubt as to whether the appliance is properly grounded.  If a grounding adapter is used, make sure the electrical box is fully grounded. 
    Grounding	wire
    ScrewTab for grounding screw
    Grounded	electri-cal box
    Grounding	adapter
    Grounding	pin
    Grounded	electrical box
    3-Pin socket
    3-Pin plug  
    						
    							EN-6
    PRECAUTIONS 
    NOTES ON OPERATION
    •	Allow	3	minutes	for	the	compressor	to	restart	cooling.   If you turn the unit off and immediately restart it, allow three minutes for the compressor to restart cooling.  There is an electronic device in the unit that keeps the compressor turned off for three minutes for safety.
    •	In	the	event	of	a	power	failure	during	use,	allow	3	minutes	before	restarting	the	unit.   After power is reinstated, restart the unit.  If the power was off for less than three min-utes, be sure to wait at least three minutes before restarting the unit.  If you restart the unit within three minutes, a protective device in the unit may cause the compressor to shut off.  This protective device will prevent cooling for about 5 minutes. Any previous settings will be cancelled and the unit will return to its initial settings.
    •	Low	temperature	operation:	Is	your	unit	freezing	up?  Freezing may occur when the unit is set close to 64°F in low ambient te\
    mperature con-ditions, especially at night.  In these conditions, a further temperature drop may cause the unit to freeze.  Setting the unit to a higher temperature will prevent it from freezing.
    •	Dehumidification	mode	increases	room	temperature. The unit generates heat during dehumidification mode and the room temperature will rise.	 Warm	 air	will	 be	blown	 out	from	 the	Exhaust	 air	outlet,	 but	this	 is	normal	 and	does	not indicate a problem with the unit.
    •	This	 unit	blows	 the	warm	 air	generated	 by	the	 unit	 outside	 the	room	 via	the	 ex-haust hose while in cool mode. Accordingly, the same amount of air as that is blown out will enter the room from outside through any openings into the room.
    •	When	 cooling	 operation	 is	performed	 at	high	 humidity	 conditions,	 water	tank	in-side the unit may frequently become full.	 When	 water	tank	inside 	the	 unit	is	 full,	 the	unit	stops	 operating	 Buzzer	will 	sound	 8	times,	LED	 window 	show 	error	 code	 H8.	In	this 	case,	 perform	 drainage	to	 drain	 out	water within the unit. 
    OPERATING CONDITIONS
    •	The	unit	must	be	operated	within	the	following	temperature	range.
    ModeRoom temperature
    Cool64°F - 95°F 
    •	A	built-in 	safety	device	 may	cut	off	operation	 if	the	temperature	 exceeds	these	limits.
    ENERGY EFFICIENCY TIPS
    •	Avoid	direct	sunlight. Close blinds, drapes or shades to keep out direct sunlight while in cooling mode.
    •	Keep	the	filter	clean.	 Keeping	 the	filter	 clean	 greatly	 aids	efficient	 operation.	 A	dirty	 filter	blocks	 the	 	flow	 of	air, making your unit work harder and less efficiently.
    •	Turn	off	unnecessary	lights.	 Your	 unit	must	 remove	 the	heat	 produced	 by	your	 lights	 or	other	 heat-producing	 appli-ances.  Turn off any lights or appliances that are not in use. 
    						
    							EN-7
    ENGLISH
    MIN.12" (30cm)
    MIN.12" (30cm)
    MIN.12" (30cm)
    •	The unit should be placed on a firm foundation to minimize noise and vibration.  For safe and secure positioning, place the	unit 	on 	a 	smooth, 	level 	floor 	strong 	enough 	to 	support 	the unit.
    •	The	unit	has	casters	 to	aid	 placement,	 but	it	should	 only	be	rolled	 on	smooth,	 flat	surfaces.		 Use	caution	 when	rolling	 on	carpet	surfaces.	Do	not	attempt	to	roll	the	unit	over	objects.
    •	The	unit 	must 	be 	placed 	within 	reach 	of 	a 	properly 	rated 	grounded socket.
    •	Never	 place	any	obstacles	 around	the	air	inlet	 or	outlet	 of	the	unit.
    •	Allow	 at	least	 12"	(30cm)	 of	space	 from	the	wall	 for	efficient	air-conditioning.
    LOCATION 
    INCLUDED
    SUGGESTED T OOLS FOR WINDOW P ANELINSTALLA TION
    1. Screw driver (medium size Phillips)  2.Tape measure or ruler  3. Knife or scissors
    4. Saw (Inthe event thatthewindow panelneeds tobe cut down insize because thewindow istoo
        narrow for direct installation.)
    Window Exhaust  Adapter A ExhaustHoseExtension panel
    Drain hose
    g
    u
    l
    p
     
    r
    e
    b
    b
    u
    R
    p
    m
    a
    l
    C
    e
    s
    o
    H Battery (2) 
    (AAA.1.5V)
    Window Exhaust Adapter 
    Manual
    Remote control
    hook (2)
    Power cordScrew (8) 
    Bracket
    Foam seal B
    (adhesive type) Foam seal A 
    Insect guard net
    Rain guard (2)
    Window 
    panel Adjustment 
    panel
    Exhaust 
    cover
    Hose clip (2)  
    						
    							EN-8
    FrontRear 21
    1
    2
    3
    4
    5 6
    7
    8
    9 1011
    12
    13 14
    15 17
    16 18
    19
    20
    1 
    Control panel and display lamp2 Remote control signal receiver window3 Handle4 Remote controller box5 Air outlet6	 Vertical	louvers7 Horizontal louvers8	 Wheel9 Air inlet10	 Grill11 Air outlet12 Air inlet13 Power cord hook14 Power cord15	 Window	exhaust	adapter	(down)16 Rain guard17 Insect guard net18	 Window	exhaust	adapter	(up)19 Exhaust hose20 Joint21 Remote control
    STRUCTURE  
    						
    All Sharp manuals Comments (0)