Page 31
29 5 Transfer charger If copies start becoming streaky or blotchy, the transfer charger may be dirty. Clean the charger using the following procedure. 1Turn the power switch off. (p.14) 2Ensure that the multi-bypass tray is open and then open the side cover while pressing the side cover open button. 3Take the charger cleaner out by holding the tab. Set the charger cleaner onto the right end of the transfer charger, gently slide the cleaner to the left end, and then remove it. Repeat this operation...
Page 32
30 This chapter describes misfeed removal and troubleshooting. TROUBLESHOOTING If any problem occurs, check the list below before contacting the SHARP service center. ProblemPossible causeSolutionPage Unit does not operate.Unit plugged in? Plug the unit into a grounded outlet.– Power switch on? Turn the power switch on. 13 Side cover closed securely? Gently close the side cover. 27 Front cover closed? Gently close the front cover and then close the side cover.27 Blank copiesIs the original placed face...
Page 33
31 6 STATUS INDICATORS When the following indicators light up or blink on the operation panel or the following alphanumeric codes appear in the display, solve the problem immediately referring to both the table below and the relevant page. Be sure to use only genuine SHARP parts and supplies. IndicationCause and remedyPage Developer replacement required indicatorSteadily litDeveloper is required. Contact your SHARP service center as soon as possible.37 Toner cartridge replacement required...
Page 34
32 MISFEED REMOVAL When the misfeed ( ) indicator blinks or blinks in the display, the unit will stop because of a misfeed. If a misfeed occurs when using the RSPF/SPF, a number may appear in the display after a minus sign. This indicates the number of the originals that must be returned to the original feeder tray after a misfeed. Return the required number of originals. Then this number will disappear when copying is resumed or the clear ( ) key is pressed. When the RSPF/SPF misfeeds an...
Page 35
33 6 A: Misfeed in the paper feed area 1Gently remove the misfed paper from the paper feed area as shown in the illustration. When the misfeed ( ) indicator blinks and the misfed paper is not seen from the paper feed area, pull out the paper tray and remove the misfed paper. If the paper cannot be removed, proceed to B: Misfeed in the fusing area. 2Close the side cover by pressing the round projections near the side cover open button. The misfeed ( ) indicator will go out and the start ( )...
Page 36
34 2Gently remove the misfed paper from under the fusing unit as shown in the illustration. If the paper cannot be removed, proceed to C: Misfeed in the transport area. 3Raise the fusing unit release lever and then close the side cover by pressing the round projections near the side cover open button. The misfeed ( ) indicator will go out and the start ( ) indicator will light up. C: Misfeed in the transport area 1Lower the fusing unit release lever. See B: Misfeed in the fusing area (p.33)....
Page 37
35 6 4Raise the fusing unit release lever, close the front cover and then close the side cover by pressing the round projections near the side cover open button. The misfeed ( ) indicator will go out and the start ( ) indicator will light up. D: Misfeed in the lower paper feed area 1Open the lower side cover (under the multi-bypass tray) and remove the misfed paper. If the misfeed ( ) indicator blinks and the misfed paper is not seen from the area of the lower side cover, pull out the lower...
Page 38
36 (B) Open the RSPF/SPF and rotate the roller rotating knob to remove the misfed original from the exit area. If the misfed original cannot be easily removed, proceed to (C). (AR-157E) With the RSPF, pull out the reversing tray to remove the misfed original. (C) If the original does not move easily into the exit area, remove it in the direction of the arrow while rotating the knob. With the RSPF, after removing the misfed original from the exit area, be sure to insert the reversing tray into the...
Page 39
37 6 DEVELOPER REQUIRED When the developer replacement required ( ) indicator lights up, the developer should be replaced. DEVELOPER REPLACEMENT SHOULD ONLY BE DONE BY AN AUTORIZED SHARP SERVICE TECHNICIAN. Contact your service center as soon as possible. MAINTENANCE REQUIRED When maintenance ( ) indicator lights up, service by an authorized SHARP service technician is required. Contact your service center as soon as possible.
Page 40
38 SYSTEM CONFIGURATION A number of options are available for the unit which allow you to configure a system to meet your particular needs. The options include the following. PRINTER/SCANNER EXPANSION KIT (AR-PG2) A printer function and scanner function can be added to the unit by installing the AR- PG2. For information on installing the software for these functions, see INSTALLING THE SOFTWARE (p.40). SINGLE PASS FEEDER (AR-SP5) The single pass feeder (SPF) holds up to 30 originals for automatic...