Page 331

 
9.  SPECIFICATIONS 
9-149   
 
Table 9-26-2 Output when overload warning is ineffective    (e.g. OLWL = 100%) 
(Alarm output sequence =BIT *²) 
CN-1 pin number for alarm output Estimated 
motor 
temperature 7-segment 
LED display 
46 
(ALM8)45 
(ALM4)44 
(ALM2)43 
(ALM1)Abbreviation Alarm/Warning
Name 
Up to 80% of 
overload alarm 
level 
80% or   
above up to 
100% of 
overload alarm 
level --  0 0 0 0  -- No alarm 
No warning 
100% or above 
of overload 
alarm level   1 1 1 1  OL Overload 
alarm...

Page 332

 
10.  INTERNATIONAL STANDARDS 
10-1   
 
 
 
 
 
 
 
INTERNATIONAL 
STANDARDS 
 
 
 
 
 
 
10.1 International Standard Compliance .............................................. 10-2 
10.1.1 Working Environment...................................................... 10-2 
10.1.2 Power Supply................................................................... 10-2 
10.2 CE Marking .................................................................................. 10-3 
10.2.1  The CE Marking Conformity...

Page 333

 
10.  INTERNATIONAL STANDARDS 
10-2 
  10.1  International Standard Compliance 
The PY2 Servo Amplifier complies with the following international standards.     
 
International standardStandard No. 
TÜV EN50178 
UL UL508C 
CUL UL508C 
Low Voltage Directive EN50178 
EMC Directive  EN55011 
 
 
 
10.1.1 Working Environment 
Since the working environment for the PY2 Servo Amplifiers must be pollution level 2 or above (i.e. level 
1 or 2) as specified in EN50178, make sure to use them in a pollution level...

Page 334

 
10.  INTERNATIONAL STANDARDS 
10-3 
 10.2 CE Marking 
At Sanyo Denki, we are executing tests on the PY2 Servo Amplifier for compliance with the CE marking 
at qualifying institutions.    The CE mark is required to be attached all end products sold in EU countries.   
Only products conforming to the safety standards are permitted to have them.  Accordingly, customers 
are requested to perform the final conformity test on their machines or systems incorporating our 
amplifiers. 
 
 
10.2.1  The CE...

Page 335

 
10.  INTERNATIONAL STANDARDS 
10-4 
10.2.2  How to Install the EMC 
 
PY2A 
 
 
 
 
 
 
 
 
 
 
 
(Note 1)  Noise filter 
(Note 2)  Zero-phase reactor 
(Note 3)  Cable clamp 
 
POWER SELECT
COM
W U
V P S
Tt
R rN
感 電 注 意
UWV
T
N
P
COM
感 電 注 意
POWER SELECTRSt r
 
CN D
MotorSensor signal
CN 2
 
L3
PEL1
L2L3T
L2
L1
S
RMC
MC
MCT S R
r
t(Note 1) 
(Note 2) 
Connect to CN1 
     Connect to the  
  PE (protective earth) 
 terminal (    ) 
(Note3)
(Note3)
(Note3)
(Note3) 

Page 336

 
10.  INTERNATIONAL STANDARDS 
10-5 
10.2.3  Structure of the Control Panel 
1.  A metallic material is used for the control panel and its cover. 
2.  The joint of the roof and the side board shall be masked and welded. 
3.  The joint fixed with screws shall be welded to prevent noise from leaking from the gap in the joint. 
4.  In case of fixing with screws or spot welding, the welding space shall be within 10 cm. 
5.  Use an EMI gasket to prevent clearance between the cover and the control panel. 
6....

Page 337

 
10.  INTERNATIONAL STANDARDS 
10-6 
10.2.4  Installation Inside the Control Panel 
1.  Install the noise filter frame on the control panel. 
2.  Apply a coating mask on the control panel where the noise filter is installed. 
3.  The Servo Amplifier box must be grounded. 
4.  Perform coating mask on the control panel where the Servo Amplifier is installed. 
 
 
 
 
 
 
 
Control panel Control panel
Servo Amplifier 
Coating mask
Coating mask
Noise filter  

Page 338

 
10.  INTERNATIONAL STANDARDS 
10-7 
10.2.5 Wiring 
1.  The motor power line shall be clamped on both the control panel and Servomotor sides. 
2.  The sensor signal line shall be clamped on both the control panel and the Servomotor sides. 
3.  Perform wiring of the motor power and sensor signal lines separately. 
 
 
 
 
 
 
4.  Install the clamp with a metal screw directly using a metal conductive P or U clip. 
5.  Do not clamp by soldering the power line to the shield....

Page 339

 
10.  INTERNATIONAL STANDARDS 
10-8  6.  Wind the zero-phase reactor four turns around the primary side of the noise filter. 
7.  Perform wiring from the secondary side of the noise filter to the Servo Amplifier, keeping it as short as 
possible. 
8.  The wiring for the primary and secondary sides of the noise filter must keep a certain distance apart. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Four turns 
Primary side 
Noise filter Secondary side
Servo Amplifier  

Page 340

 
10.  INTERNATIONAL STANDARDS 
10-9 
10.2.6  Parts for EMC Countermeasures 
We recommend the following parts for EMC countermeasures. 
 
Noise filter 
 
Model Maker Specifications 
RF3020-DLC  RASMI ELECTRONICS LTD. Rated voltage:  Line-Line    440 - 550V 
Rated current:  20 A 
3SUP-HK30-ER-6B Okaya Electric Industry Co., Ltd.Rated voltage: Line-Line  550V 
Rated current:  30 A 
 
 
 
Zero-phase reactor 
 
Model Maker Specifications 
RZR-6020N Okaya Electric Industry Co., Ltd.1 kHz - 100 kHz    6.9 to...