Page 11
access memory (NV-RAM) located on the remov- able SMEM card. It is protected by a super capaci- tor providing seven days of memory protection in the event of loss of AC power to the system. 2.4 INTERFACE CARDS 2 SLI This card is installed in a dedicated slot on the KSU motherboard. The card provides two single line tele- phone interfaces equipped with OPX protection and the ability to provide a loop disconnect signal. This is the same card used on the DCS Compact. 2 x 4 DLI This card provides...
Page 12
2.3 2 E & M x 4 DLI This card provides two two wire (TL11M) tie line interfaces and four 1B+D DLI ports. KDb’s cannot be used with this card. This is the same card used on the DCS Compact. S4BRI This card provides 4 ISDN Basic Rate Interface (BRI) S/T circuits with the ability to sup- port two channels per circuit for a total of 8 channels. A system can have up to six of these cards. These S/T circuits can be configured for station or trunk use. An NT1 is required for connection to a telephone...
Page 13
This fully featured self contained system is connected directly to the DCS 50si data bus and communicates with the DCS 50si system processor. This design means that installation time is minimized, operation is stream- lined and many features can be implemented that are not normally possible with older conventional stand alone Voice Mail/Auto Attendant systems. All power to run this self contained system comes from the DCS 50si telephone system power supply. The DCS 50si power supply is rated...
Page 14
2.5 2.5 STATION EQUIPMENT LCD 24B Keyset (See Figures 2–5) Built-in speakerphone 24 programmable keys (16 with tri-colored LEDs) Four fixed function keys 32 character display (2 x 16) with three associated soft keys and a scroll key UP/DOWN buttons for digital control of speaker, handset and ringer volumes Eight selectable ring tones Desk- or wall-mounted Available in almond or charcoal STD 24B Keyset (See Figures 2–6) Built-in speakerphone 24 programmable keys (16 with tri-col- ored...
Page 15
2.6 Basic 12B Model Keyset (see Figures 2–8) Built-in speakerphone 12 programmable keys (six with tri-col- ored LEDs) Four fixed function keys UP/DOWN buttons for digital control of speaker, handset and ringer volumes Eight selectable ring tones Desk- or wall-mounted Available in almond or charcoal 7 Button Model Keyset (see Figures 2–9) 7 programmable keys Three fixed function keys UP/DOWN buttons for digital control of speaker and ringer volumes Eight selectable ring tones Desk or...
Page 16
2.7 FIGURE 2–11 Door Phone Interface Module (DPIM) and Door Phone (see Figures 2–12 and 2–13) The DPIM adapts any DLI circuit for use with the door phone unit Commonly used to request entry through locked doors (interior or exterior) or as a room monitoring box Provides contact control to be used with cus- tomer-provided electric door lock Door phone is wall-mounted Door phone is weather resistant FIGURE 2–12 FIGURE 2–13
Page 17
2.8 Serial Interface Module (SIM) (See Figure 2–14) Provides an RS232 connection required for SMDR, PCMMC and TSAPI Connects to any DLI circuit FIGURE 2–14 FIGURE 2–15 Computer Telephony Module (CTM) (See Figure 2–15) Provides RS232 connection via DB9 for TAPI applications Connects with any DLI port
Page 18
2.9 64 Button Module (See Figure 2–16) 64 programmable keys Available in almond and charcoal A maximum of 2 can be assigned to any DCS keyset to provide additional programmable keys A maximum of 4 per DCS System FIGURE 2–16 Single Line Telephone (See Figure 2–17) Four fixed function keys: hold, flash, new call, and monitor. Data Port: selectable to share station ex- tension or utilize a separate extension On hook dialing Message Waiting/Ring Indicator Desk or wall mounted Ring volume...
Page 19
3.1 PART 3. SPECIFICATIONS The following tables provide technical data for the DCS 50si hybrid/key telephone system. 3.1 ELECTRICAL SPECIFICATIONS AC INPUT 112 (88–132) VAC (48–63 Hz) POWER CONSUMPTION (MAX) 97 WATTS MAXIMUM FUSE RATING 5 AMP BTU RATING (MAX) 5.5 BTU/MINUTE DC OUTPUT +5 VOLTS 2.5 AMPS MAX -5 VOLTS 0.5 AMPS MAX -48 VOLTS 1.2 AMPS MAXIMUM BATTERIES 10–40 AMPS 48 VOLTS MAXIMUM CHARGE CURRENT 0.4 A MAXIMUM DISCHARGE RATE 2.5 A 3.2DIMENSIONS AND WEIGHTS HEIGHT WIDTH DEPTH WEIGHT DCS...
Page 20
3.2 3.3ENVIRONMENTAL LIMITS OPERATING TEMPERATURE 32–104 °F/1–40 °C STORAGE TEMPERATURE -13–158 °F/-10.5–70 °C HUMIDITY 10%-90% NON-CONDENSING 3.4CABLE REQUIREMENTS EQUIPMENT CABLE AWG MAX FEET MAX METERS DIGITAL KEYSETS 1 PR. TWISTED 24 1300 400 ADD-ON MODULES 1 PR. TWISTED 24 1300 400 SINGLE LINE STATION 1 PR. TWISTED 24 3000 1 KM DOOR PHONE 2 PR. TWISTED 24 330* 100 *This is the maximum length of the cable between the door phone and the \ DPIM. The DPIM can be installed up to 900 cable feet from the...