Runco X 450d Projector User Manual
Have a look at the manual Runco X 450d Projector User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 123 Runco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
External Control Runco X-400d/X-450d Installation/Operation Manual 125 PREL IMINARY COMP 8209 72 0x201148B7 Component video input HD 1 8209 73 0x201149B6 HD1 video input HD 2 8209 74 0x20114AB5 HD2 video input HDMI 1 8209 75 0x20114BB4 HDMI1 video input HDMI 2 8209 76 0x20114CB3 HDMI2 video input HDMI 3 8209 77 0x20114DB2 HDMI3 video input HDMI 4 8209 78 0x20114EB1 HDMI4 video input HDMI 5 8209 79 0x20114FB0 HDMI5 video input HDMI 6 8209 80 0x201150AF HDMI6 video input HDMI 7 8209 81 0x201151AE HDMI7 video input HDMI 8 8209 82 0x201152AD HDMI8 video input DisplayPort 8209 83 0x201153AC DisplayPort video input SCART 8209 84 0x201154AB SCART video input VIDEO 2 8209 85 0x201155AA Composite video input 2 VIDEO 3 8209 86 0x201156A9 Composite video input 3 3D OFF 8209 87 0x201157A8 3D Mode = Off Auto Cinema 8209 88 0x201158A7 Auto Cinema aspect ratio Table 6-2. NEC Control Codes for the Dimension Digital Controller (Standard Mode) (continued) Remote Control Button NameAddressDataNEC Data From Remote (Note)Description Note: These codes assume that the default address of 8209 is used. If you change it to something other than 8209, you will need to modify these codes accordingly.
External Control 126 Runco X-400d/X-450d Installation/Operation Manual PREL IMINARY IR Command List (Extended Mode)Table 6-3 lists the Extended-mode NEC control codes for the Dimension Digital Controller. To use the remote control unit in extended mode, set the address code to 88999 (refer to Remote Control on page 87). ➤ Table 6-3. NEC Control Codes for the Dimension Digital Controller (Extended Mode) Remote Control Button NameAddressDataNEC Data From Remote (Note)Description ON 8209 65 0x201141BE Sets the sleep timer to Off OFF (standby) 8209 66 0x201142BD Sets the sleep timer to 30 minutes 16:9 8209 67 0x201143BC Sets the sleep timer to 60 minutes 4:3 8209 68 0x201144BB Sets the sleep timer to 90 minutes LETBOX 8209 69 0x201145BA Sets the sleep timer to 2 hours V-WIDE 8209 70 0x201146B9 Sets the sleep timer to 4 hours CINEMA 8209 71 0x201147B8 Composite video input 1 V-CINE 8209 72 0x201148B7 Component video input NATIVE 8209 73 0x201149B6 HD1 video input 1 8209 74 0x20114AB5 HD2 video input 2 8209 75 0x20114BB4 HDMI1 video input 3 8209 76 0x20114CB3 HDMI2 video input 4 8209 77 0x20114DB2 HDMI3 video input 5 8209 78 0x20114EB1 HDMI4 video input 6 8209 79 0x20114FB0 HDMI5 video input 7 8209 80 0x201150AF HDMI6 video input 8 8209 81 0x201151AE HDMI7 video input 9 8209 82 0x201152AD HDMI8 video input 0 8209 83 0x201153AC DisplayPort video input ISF DAY 8209 84 0x201154AB SCART video input ISF NIGHT 8209 85 0x201155AA Composite video input 2 SCREEN 1 8209 86 0x201156A9 Composite video input 3 CUST 1 8209 87 0x201157A8 3D Mode = Off CUST 2 8209 88 0x201158A7 Auto Cinema aspect ratio Note: These codes assume that the default address of 8209 is used. If you change it to something other than 8209, you will need to modify these codes accordingly.
External Control Runco X-400d/X-450d Installation/Operation Manual 127 PREL IMINARY 6.3 Using HDMI CEC MessagesThe Dimension Digital Controller accepts and can respond to CEC command messages from a disc player, satellite receiver or DVR/set-top box via an HDMI connection. Using CEC, the Dimension Digital Controller can perform the following actions: Turn itself and the projector on and select the correct input when the source component initiates playback of a disc or recorded program. Turn the source component on when you switch to its corresponding input on the Dimension Digital Controller. Turn the source component off when the X-400d/X-450d system is turned off (unless the source component is in playback mode). Change its OSD language when a similar change is made at the source. To use CEC, connect your CEC-compatible sources to the HDMI inputs on the Dimension Digital Controller. Set the CEC option to On (refer to CEC on page 96). Additional steps may be needed to enable CEC at the source. Refer to the documentation for your source device for more information. CEC Command List Table 6-4 lists the CEC commands supported by the Dimension Digital Controller. Table 6-4. CEC Commands Supported by the Dimension Digital Controller Opcode ValueSupported? (√ = Yes, – = No) Initiator Follower Feature Abort 0x00 √√ Standby 0x36 √√ Routing Change 0x80 √√ Routing Information 0x81 √√ Active Source 0x82 √√ Request Active Source 0x85 √√ Device Vendor ID 0x87 √√ Give Device Vendor ID 0x8C √√ Vendor Command With ID 0xA0 √√ Polling Message N/A √√ Text View On 0x0D √ – Report Physical Address 0x84 √ – Inactive Source 0x9D √ – CEC Version 0x9E √ – Set OSD Name 0x47 √ – Menu Status 0x8E √ – Report Power Status 0x90 √ –
External Control 128 Runco X-400d/X-450d Installation/Operation Manual PREL IMINARY Set Menu Language 0x32–√ Give Physical Address 0x83 –√ Set Stream Path 0x86 –√ Get CEC Version 0x9F –√ Abort Message 0xFF –√ User Control Pressed 0x44 –√ User Control Released 0x45 –√ Give OSD Name 0x46 –√ Menu Request 0x8D –√ Give Device Power Status 0x8F –√ The Dimension Digital Controller does not transmit HDMI CEC control messages from the “HDMI Audio Out” connector. Table 6-4. CEC Commands Supported by the Dimension Digital Controller (continued) Opcode ValueSupported? (√ = Yes, – = No) Initiator Follower Note
Specifications Runco X-400d/X-450d Installation/Operation Manual 129 PREL IMINARY 7.1 X-400d/X-450d Projector SpecificationsTable 7-1 lists the X-400d/X-450d projector specifications. 7. Specifications Table 7-1. X-400d/X-450d Projector Specifications Projector Type:3-chip Texas Instruments Digital Light Processing™ (DLP), SuperOnyx™ DMD™, 3D capable Processing: Runco Dimension Digital Controller with ViVix IV™ technology and BRiC (Backup, Recovery and Clone) tool Native Resolution:Full HD 1920 x 1080 (1080p) Aspect Ratios: 4:3, Letterbox, 16:9, VirtualWide, Cinema, Virtual Cinema, Native, Auto Cinema Video Standards:Refer to Table 7-2 Video Compatibility:Refer to Table 7-3 Picture Size (16:9 Screen): X-400d Recommended Width: 80 - 115 in. Maximum Width: 175 in. X-450d Recommended Width: 107 - 154 in. Maximum Width: 235 in. Throw Distance (Factor x Screen Width): Refer to Table 3-3 Horizontal & Vertical Offset: Proteus 1: None Proteus 2, 3, 4, 5, 6: Horizontal: 30% of screen width left or right Vertical: 65% of screen height up or down Illumination System: 230W / 260W (selectable) HPM lamp Estimated Lamp Life: 2000 hours, typical (260W power setting) 3000 hours, typical (230W power setting) Inputs and Outputs: Digital Video x 2 (from Dimension Digital Controller) RS-232 (female DB9) for serial communications 3D Sync Out (female 3-pin, VESA standard mini-DIN) to RF Emitter Power Requirements: 100 to 240 VAC (auto-sensing), 50/60 Hz, 400 Watts (1365.2 BTUs/hour) maximum Operating Temperature: 10°C to 40°C, up to 7,500’ altitude 10°C to 35°C, 7,500’ to 10,000’ altitude Operating Humidity:0 - 85% humidity (non-condensing) Regulatory Approvals: FCC Part 15 Class B, CE Class B, UL, cUL, CB, RoHS, WEEE, local conformances as required
Specifications 130 Runco X-400d/X-450d Installation/Operation Manual PRELI MINARY Brightness and Contrast (2D):Cinema Standards Measurement System (CSMS) Specifications - X-400d - Brightness: 52 foot-Lamberts (fL) - Contrast Ratio: >250:1 CSMS Specifications - X-450d - Brightness: 94 foot-Lamberts (fL) - Contrast Ratio: >200:1 These measurements are taken from the projector in a controlled, home theater environment. All measurements are made to ANSI/NAPM IT7.228-1997 specifications using a 1.0 gain, 84-inch wide screen. The foot-Lambert (fL) is the unit of measurement used in commercial movie theaters to express image brightness at the screen surface. The Society of Motion Picture and Television Engineers (SMPTE) specifies 16 fL as the target image brightness for film-based projectors using an open gate (without film in the projector). More importantly, today SMPTE specifies 12 fL as the target image brightness in Digital Cinema theaters. The foot-Lambert measurement is dependent on screen size, screen gain and projector light output. Home Theater Calibration Specifications - X-400d - Light Output: 1,440 ANSI Lumens - Contrast Ratio: >250:1 Home Theater Calibration Specifications - X-450d - Light Output: 2,592 ANSI Lumens - Contrast Ratio: >200:1 These specifications are obtained by calibrating the projector as described above for CSMS measurements. Industry-Standard Specifications - X-400d - Light Output: 2,100 ANSI Lumens (uncalibrated) - Contrast Ratio: 10,000:1 full-on, full-off Industry-Standard Specifications - X-450d - Light Output: 3,780 ANSI Lumens (uncalibrated) - Contrast Ratio: 1,200:1 full-on, full-off These are typical projector brightness and contrast specifications found in most companies’ sales literature. Runco includes these measurements in its literature to allow for direct comparison with other manufacturers’ projectors. These measurements are typically taken at 9,000K to 13,000K to get expected performance data when the projector is used in professional, commercial and industrial displays. Control Options: Serial commands via RS-232 Discrete infrared (IR) remote Consumer Electronics Control (CEC) protocol support via HDMI Calibration:ISF Certified Calibration Configuration Color Gamut:> BT.709 (REC709) Lens System: Motorized focus, zoom and position controls Table 7-1. X-400d/X-450d Projector Specifications (continued)
Specifications Runco X-400d/X-450d Installation/Operation Manual 131 PREL IMINARY Refresh Rate:50 Hz or 60 Hz (2D content) 100 Hz or 120 Hz (3D content) 3D Technology:Frame sequential, active shutter Dimensions:See Figure 7-1 Weight (without lens):55.5 lbs. (25.2 kg) Limited Warranty: Projector: (2) Two years parts and labor from the date of shipment from Runco. Extended RuncoCare™, Red Carpet™, and PremierCare™ also available. Lamp: 1000 hours or six (6) months, whichever comes first (US and Canada only) Specifications are subject to change without notice. Table 7-1. X-400d/X-450d Projector Specifications (continued)
Specifications 132 Runco X-400d/X-450d Installation/Operation Manual PRELI MINARY 7.2 Dimension Digital Controller SpecificationsTable 7-2 lists the Dimension Digital Controller specifications. Table 7-2. Dimension Digital Controller Specifications Aspect Ratios: 4:3, Letterbox, 16:9, VirtualWide, Cinema, Virtual Cinema, Native, Auto Cinema Video Standards: DisplayPort with HDCP HDMI and DVI with HDCP for digital video Component and RGB HDTV (1080p, 1080i, 720p) Component and RGB EDTV (576p, 480p) Component and Composite SDTV (576i, 480i) RGB SCART with adaptor NTSC (M, 4.43) PAL (B, G, H, I, N, M) Inputs: (1) DisplayPort 1.1a (8) HDMI with 3D Support, CEC and Deep Color (1) Component/SCART (3 x RCA) (2) Component/RGBHV (15-pin VGA) (3) Composite Outputs: (2) HDMI with 3D Support and Deep Color to X-400d/X-450d (1) HDMI with Deep Color to second display or audio processor Control Options: Front panel vacuum fluorescent display and keypad Discrete infrared (IR) remote RS-232 (female DB9) for serial commands USB (type B female) for firmware upgrade RS-232 (male DB9) for accessories 3.5-mm wired IR input for Niles/Xantech-compatible IR systems Consumer Electronics Control (CEC) protocol support via HDMI Ethernet Communication: RJ45 (female) for web server, e-mail, auto firmware upgrade and Telnet RS-232 Communication Parameters: 19200 bps, no parity, 8 data bits, 1 stop bit, no flow control Trigger Outputs: (3) +12 VDC, each rated at 250 mA and thermal fuse-protected Accessory Applications: Runco Firmware Upgrader, Runco BRiC (backup, restore, clone), CalMAN by SpectraCal for automatic calibration Power Requirements: 100-240V~, 47-63Hz, 0.85 Amps Operating Environment:41°F to 104°F (5°C to 40°C), 0% to 90% humidity (non-condensing); up to 10,000 feet (3,048 meters) altitude
Specifications Runco X-400d/X-450d Installation/Operation Manual 133 PREL IMINARY Dimensions:Width = 17.50 inches (444.5 mm) Depth = 17.68 inches (449.0 mm) Height = 3.75 inches (95.3 mm) Weight: 17.6 lbs. (8.00 kg) Regulatory Approvals:cTUVus, FCC class B, CE, RoHS, China RoHS, WEEE, C-Tick, CCC, local conformances as required Limited Warranty: Two (2) years parts and labor from the date of shipment from Runco. Specifications are subject to change without notice. Table 7-2. Dimension Digital Controller Specifications (continued)
Specifications 134 Runco X-400d/X-450d Installation/Operation Manual PRELI MINARY 7.3 Supported TimingsTable 7-3 lists the signal types supported by each input on the Dimension Digital Controller. Table 7-3. Supported Signal Timings by Input Format ResolutionRefresh Rate (Hz)Horizontal Frequency (kHz)Pixel Frequency (MHz)Supported? (√ = Yes, – = No) HD 1 HD 2 HDMI [1 ... 8] DisplayPort Component SCART Composite 1 Composite 2 Composite 3 Supported 3D Modes 1080i SBS (Side-by- Side)1920x108050.00 28.125/31.250 74.250/72.000 –√–––– 59.94 33.716 74.175 –√–––– 60.00 33.750 74.250 –√–––– 720p TAB (Top-and- Bottom)1280x72050.00 37.500 75.250 –√–––– 59.94 44.715 74.406 –√–––– 60.00 45.000 74.250 –√–––– 720p SBS (Side-by- Side)1280x72050.00 37.500 75.250 –√–––– 59.94 44.715 74.406 –√–––– 60.00 45.000 74.250 –√–––– 720p FP (Frame Packing)1280x72023.98 17.982 59.341 –√–––– 24.00 18.000 59.400 –√–––– 29.97 22.478 74.175 –√–––– 30.00 22.500 74.250 –√–––– 50.00 37.500 75.250 –√–––– 59.94 44.715 74.406 –√–––– 60.00 45.000 74.250 –√–––– 1080p SBS (Side-by- Side)1920x108023.98 26.978 74.175 –√–––– 24.00 27.000 74.250 –√–––– 29.97 33.716 74.175 –√–––– 30.00 33.750 74.250 –√–––– 50.00 56.250 148.500 –√–––– 59.94 67.433 148.350 –√–––– 60.00 67.500 148.500 –√––––