Home > Runco > Projector > Runco X 450d Projector User Manual

Runco X 450d Projector User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Runco X 450d Projector User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 123 Runco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							External Control
    Runco X-400d/X-450d Installation/Operation Manual 125 
    PREL
    IMINARY
    COMP 8209 72 0x201148B7 Component video input
    HD 1 8209 73 0x201149B6 HD1 video input
    HD 2 8209 74 0x20114AB5 HD2 video input
    HDMI 1 8209 75 0x20114BB4 HDMI1 video input
    HDMI 2 8209 76 0x20114CB3 HDMI2 video input
    HDMI 3 8209 77 0x20114DB2 HDMI3 video input
    HDMI 4 8209 78 0x20114EB1 HDMI4 video input
    HDMI 5 8209 79 0x20114FB0 HDMI5 video input
    HDMI 6 8209 80 0x201150AF HDMI6 video input
    HDMI 7 8209 81 0x201151AE HDMI7 video input
    HDMI 8 8209 82 0x201152AD HDMI8 video input
    DisplayPort 8209 83 0x201153AC DisplayPort video input
    SCART 8209 84 0x201154AB SCART video input
    VIDEO 2 8209 85 0x201155AA Composite video input 2
    VIDEO 3 8209 86 0x201156A9 Composite video input 3
    3D OFF 8209 87 0x201157A8 3D Mode = Off
    Auto Cinema 8209 88 0x201158A7 Auto Cinema aspect ratio
    Table 6-2. NEC Control Codes for the Dimension Digital Controller 
    (Standard Mode) (continued)
    Remote 
    Control 
    Button NameAddressDataNEC Data 
    From Remote 
    (Note)Description
    Note: These codes assume that the default address of 8209 is used. If you change it to something 
    other than 8209, you will need to modify these codes accordingly.  
    						
    							External Control
    126 Runco X-400d/X-450d Installation/Operation Manual
    PREL
    IMINARY
    IR Command List
    (Extended Mode)Table 6-3 lists the Extended-mode NEC control codes for the Dimension Digital 
    Controller. To use the remote control unit in extended mode, set the address code to 
    88999 (refer to Remote Control on page 87). ➤
    Table 6-3. NEC Control Codes for the Dimension Digital Controller 
    (Extended Mode)
    Remote 
    Control 
    Button NameAddressDataNEC Data 
    From Remote 
    (Note)Description
    ON 8209 65 0x201141BE Sets the sleep timer to Off
    OFF (standby) 8209 66 0x201142BD Sets the sleep timer to 30 minutes
    16:9 8209 67 0x201143BC Sets the sleep timer to 60 minutes
    4:3 8209 68 0x201144BB Sets the sleep timer to 90 minutes
    LETBOX 8209 69 0x201145BA Sets the sleep timer to 2 hours
    V-WIDE 8209 70 0x201146B9 Sets the sleep timer to 4 hours
    CINEMA 8209 71 0x201147B8 Composite video input 1
    V-CINE 8209 72 0x201148B7 Component video input
    NATIVE 8209 73 0x201149B6 HD1 video input
    1 8209 74 0x20114AB5 HD2 video input
    2 8209 75 0x20114BB4 HDMI1 video input
    3 8209 76 0x20114CB3 HDMI2 video input
    4 8209 77 0x20114DB2 HDMI3 video input
    5 8209 78 0x20114EB1 HDMI4 video input
    6 8209 79 0x20114FB0 HDMI5 video input
    7 8209 80 0x201150AF HDMI6 video input
    8 8209 81 0x201151AE HDMI7 video input
    9 8209 82 0x201152AD HDMI8 video input
    0 8209 83 0x201153AC DisplayPort video input
    ISF DAY 8209 84 0x201154AB SCART video input
    ISF NIGHT 8209 85 0x201155AA Composite video input 2
    SCREEN 1 8209 86 0x201156A9 Composite video input 3
    CUST 1 8209 87 0x201157A8 3D Mode = Off
    CUST 2 8209 88 0x201158A7 Auto Cinema aspect ratio
    Note: These codes assume that the default address of 8209 is used. If you change it to something 
    other than 8209, you will need to modify these codes accordingly.  
    						
    							External Control
    Runco X-400d/X-450d Installation/Operation Manual 127 
    PREL
    IMINARY
    6.3 
    Using HDMI CEC 
    MessagesThe Dimension Digital Controller accepts and can respond to CEC command messages 
    from a disc player, satellite receiver or DVR/set-top box via an HDMI connection. Using 
    CEC, the Dimension Digital Controller can perform the following actions:
     Turn itself and the projector on and select the correct input when the source 
    component initiates playback of a disc or recorded program. 
     Turn the source component on when you switch to its corresponding input on the 
    Dimension Digital Controller. 
     Turn the source component off when the X-400d/X-450d system is turned off (unless 
    the source component is in playback mode). 
     Change its OSD language when a similar change is made at the source. 
    To use CEC, connect your CEC-compatible sources to the HDMI inputs on the Dimension 
    Digital Controller. Set the CEC option to On (refer to CEC on page 96). Additional steps 
    may be needed to enable CEC at the source. Refer to the documentation for your source 
    device for more information. 
    CEC Command List Table 6-4 lists the CEC commands supported by the Dimension Digital Controller. 
    Table 6-4. CEC Commands Supported by the Dimension Digital 
    Controller
    Opcode ValueSupported? (√ = Yes, – = No)
    Initiator Follower
    Feature Abort 0x00
    √√
    Standby 0x36
    √√
    Routing Change 0x80
    √√
    Routing Information 0x81
    √√
    Active Source 0x82
    √√
    Request Active Source 0x85
    √√
    Device Vendor ID 0x87
    √√
    Give Device Vendor ID 0x8C
    √√
    Vendor Command With ID 0xA0
    √√
    Polling Message N/A
    √√
    Text View On 0x0D
    √
    –
    Report Physical Address 0x84
    √
    –
    Inactive Source 0x9D
    √
    –
    CEC Version 0x9E
    √
    –
    Set OSD Name 0x47
    √
    –
    Menu Status 0x8E
    √
    –
    Report Power Status 0x90
    √
    – 
    						
    							External Control
    128 Runco X-400d/X-450d Installation/Operation Manual
    PREL
    IMINARY
    Set Menu Language 0x32–√
    Give Physical Address 0x83
    –√
    Set Stream Path 0x86
    –√
    Get CEC Version 0x9F
    –√
    Abort Message 0xFF
    –√
    User Control Pressed 0x44
    –√
    User Control Released 0x45
    –√
    Give OSD Name 0x46
    –√
    Menu Request 0x8D
    –√
    Give Device Power Status 0x8F
    –√
    The Dimension Digital Controller does not transmit HDMI CEC 
    control messages from the “HDMI Audio Out” connector. 
    Table 6-4. CEC Commands Supported by the Dimension Digital Controller 
    (continued)
    Opcode ValueSupported? (√ = Yes, – = No)
    Initiator Follower
    Note 
    						
    							Specifications
    Runco X-400d/X-450d Installation/Operation Manual 129 
    PREL
    IMINARY
    7.1 
    X-400d/X-450d 
    Projector 
    SpecificationsTable 7-1 lists the X-400d/X-450d projector specifications.  
    7. Specifications
    Table 7-1. X-400d/X-450d Projector Specifications
    Projector Type:3-chip Texas Instruments Digital Light Processing™ (DLP), 
    SuperOnyx™ DMD™, 3D capable
    Processing: Runco Dimension Digital Controller with ViVix IV™ technology 
    and BRiC (Backup, Recovery and Clone) tool
    Native Resolution:Full HD 1920 x 1080 (1080p)
    Aspect Ratios: 4:3, Letterbox, 16:9, VirtualWide, Cinema, Virtual Cinema, 
    Native, Auto Cinema
    Video Standards:Refer to Table 7-2
    Video Compatibility:Refer to Table 7-3
    Picture Size (16:9 Screen): X-400d
    Recommended Width: 80 - 115 in.
    Maximum Width: 175 in.
    X-450d
    Recommended Width: 107 - 154 in.
    Maximum Width: 235 in.
    Throw Distance
    (Factor x Screen Width): Refer to Table 3-3
    Horizontal & Vertical Offset: Proteus 1: None
    Proteus 2, 3, 4, 5, 6: 
    Horizontal: 30% of screen width left or right
    Vertical: 65% of screen height up or down
    Illumination System: 230W / 260W (selectable) HPM lamp
    Estimated Lamp Life: 2000 hours, typical (260W power setting)
    3000 hours, typical (230W power setting)
    Inputs and Outputs:  Digital Video x 2 (from Dimension Digital Controller)
     RS-232 (female DB9) for serial communications
     3D Sync Out (female 3-pin, VESA standard mini-DIN) to RF 
    Emitter
    Power Requirements: 100 to 240 VAC (auto-sensing), 50/60 Hz, 400 Watts 
    (1365.2 BTUs/hour) maximum
    Operating Temperature: 10°C to 40°C, up to 7,500’ altitude 
    10°C to 35°C, 7,500’ to 10,000’ altitude
    Operating Humidity:0 - 85% humidity (non-condensing)
    Regulatory Approvals: FCC Part 15 Class B, CE Class B, UL, cUL, CB, RoHS, 
    WEEE, local conformances as required 
    						
    							Specifications
    130 Runco X-400d/X-450d Installation/Operation Manual
    PRELI
    MINARY
    Brightness and Contrast 
    (2D):Cinema Standards Measurement System (CSMS) 
    Specifications - X-400d
    - Brightness: 52 foot-Lamberts (fL)
    - Contrast Ratio: >250:1
    CSMS Specifications - X-450d
    - Brightness: 94 foot-Lamberts (fL)
    - Contrast Ratio: >200:1
    These measurements are taken from the projector in a controlled, 
    home theater environment. All measurements are made to 
    ANSI/NAPM IT7.228-1997 specifications using a 1.0 gain, 84-inch 
    wide screen. 
    The foot-Lambert (fL) is the unit of measurement used in commercial 
    movie theaters to express image brightness at the screen surface. The 
    Society of Motion Picture and Television Engineers (SMPTE) specifies 
    16 fL as the target image brightness for film-based projectors using an 
    open gate (without film in the projector). More importantly, today 
    SMPTE specifies 12 fL as the target image brightness in Digital 
    Cinema theaters. The foot-Lambert measurement is dependent on 
    screen size, screen gain and projector light output.
    Home Theater Calibration Specifications - X-400d
    - Light Output: 1,440 ANSI Lumens
    - Contrast Ratio: >250:1
    Home Theater Calibration Specifications - X-450d
    - Light Output: 2,592 ANSI Lumens
    - Contrast Ratio: >200:1
    These specifications are obtained by calibrating the projector as 
    described above for CSMS measurements. 
    Industry-Standard Specifications - X-400d
    - Light Output: 2,100 ANSI Lumens (uncalibrated)
    - Contrast Ratio: 10,000:1 full-on, full-off 
    Industry-Standard Specifications - X-450d
    - Light Output: 3,780 ANSI Lumens (uncalibrated)
    - Contrast Ratio: 1,200:1 full-on, full-off 
    These are typical projector brightness and contrast specifications 
    found in most companies’ sales literature. Runco includes these 
    measurements in its literature to allow for direct comparison with other 
    manufacturers’ projectors. These measurements are typically taken at 
    9,000K to 13,000K to get expected performance data when the 
    projector is used in professional, commercial and industrial displays.
    Control Options: Serial commands via RS-232
     Discrete infrared (IR) remote
     Consumer Electronics Control (CEC) protocol support via 
    HDMI
    
    Calibration:ISF Certified Calibration Configuration
    Color Gamut:> BT.709 (REC709)
    Lens System: Motorized focus, zoom and position controls
    Table 7-1. X-400d/X-450d Projector Specifications (continued) 
    						
    							Specifications
    Runco X-400d/X-450d Installation/Operation Manual 131 
    PREL
    IMINARY
    Refresh Rate:50 Hz or 60 Hz (2D content)
    100 Hz or 120 Hz (3D content)
    3D Technology:Frame sequential, active shutter
    Dimensions:See Figure 7-1
    Weight (without lens):55.5 lbs. (25.2 kg)
    Limited Warranty: Projector: (2) Two years parts and labor from the date of 
    shipment from Runco. Extended RuncoCare™, Red 
    Carpet™, and PremierCare™ also available.
    Lamp: 1000 hours or six (6) months, whichever comes first 
    (US and Canada only)
    Specifications are subject to change without notice. 
    Table 7-1. X-400d/X-450d Projector Specifications (continued) 
    						
    							Specifications
    132 Runco X-400d/X-450d Installation/Operation Manual
    PRELI
    MINARY
    7.2 
    Dimension Digital 
    Controller 
    SpecificationsTable 7-2 lists the Dimension Digital Controller specifications.  
    Table 7-2. Dimension Digital Controller Specifications
    Aspect Ratios: 4:3, Letterbox, 16:9, VirtualWide, Cinema, Virtual Cinema, 
    Native, Auto Cinema
    Video Standards: DisplayPort with HDCP
     HDMI and DVI with HDCP for digital video
     Component and RGB HDTV (1080p, 1080i, 720p)
     Component and RGB EDTV (576p, 480p)
     Component and Composite SDTV (576i, 480i)
     RGB SCART with adaptor
     NTSC (M, 4.43)
     PAL (B, G, H, I, N, M)
    
    
    
    Inputs: (1) DisplayPort 1.1a
    (8) HDMI with 3D Support, CEC and Deep Color
    (1) Component/SCART (3 x RCA)
    (2) Component/RGBHV (15-pin VGA)
    (3) Composite
    Outputs: (2) HDMI with 3D Support and Deep Color to X-400d/X-450d
    (1) HDMI with Deep Color to second display or audio 
    processor
    Control Options: Front panel vacuum fluorescent display and keypad
     Discrete infrared (IR) remote
     RS-232 (female DB9) for serial commands
     USB (type B female) for firmware upgrade
     RS-232 (male DB9) for accessories
     3.5-mm wired IR input for Niles/Xantech-compatible IR 
    systems
     Consumer Electronics Control (CEC) protocol support via 
    HDMI
    
    Ethernet Communication: RJ45 (female) for web server, e-mail, auto firmware upgrade 
    and Telnet
    RS-232 Communication 
    Parameters: 19200 bps, no parity, 8 data bits, 1 stop bit, no flow control
    Trigger Outputs: (3) +12 VDC, each rated at 250 mA and thermal 
    fuse-protected
    Accessory Applications: Runco Firmware Upgrader, Runco BRiC (backup, restore, 
    clone), CalMAN by SpectraCal for automatic calibration
    Power Requirements: 100-240V~, 47-63Hz, 0.85 Amps
    Operating Environment:41°F to 104°F (5°C to 40°C), 0% to 90% humidity
    (non-condensing); up to 10,000 feet (3,048 meters) altitude 
    						
    							Specifications
    Runco X-400d/X-450d Installation/Operation Manual 133 
    PREL
    IMINARY
    Dimensions:Width = 17.50 inches (444.5 mm)
    Depth = 17.68 inches (449.0 mm)
    Height = 3.75 inches (95.3 mm)
    Weight: 17.6 lbs. (8.00 kg)
    Regulatory Approvals:cTUVus, FCC class B, CE, RoHS, China RoHS, WEEE, 
    C-Tick, CCC, local conformances as required
    Limited Warranty: Two (2) years parts and labor from the date of shipment from 
    Runco.
    Specifications are subject to change without notice. 
    Table 7-2. Dimension Digital Controller Specifications (continued) 
    						
    							Specifications
    134 Runco X-400d/X-450d Installation/Operation Manual
    PRELI
    MINARY
    7.3 
    Supported TimingsTable 7-3 lists the signal types supported by each input on the Dimension Digital 
    Controller. 
    Table 7-3. Supported Signal Timings by Input
    Format ResolutionRefresh 
    Rate (Hz)Horizontal 
    Frequency 
    (kHz)Pixel Frequency 
    (MHz)Supported? (√ = Yes, – = No)
    HD 1
    HD 2
    HDMI [1 ... 8]
    DisplayPort
    Component
    SCART
    Composite 1
    Composite 2
    Composite 3
    Supported 3D Modes
    1080i SBS 
    (Side-by-
    Side)1920x108050.00 28.125/31.250 74.250/72.000
    –√––––
    59.94 33.716 74.175
    –√––––
    60.00 33.750 74.250
    –√––––
    720p TAB 
    (Top-and-
    Bottom)1280x72050.00 37.500 75.250
    –√––––
    59.94 44.715 74.406
    –√––––
    60.00 45.000 74.250
    –√––––
    720p SBS 
    (Side-by-
    Side)1280x72050.00 37.500 75.250
    –√––––
    59.94 44.715 74.406
    –√––––
    60.00 45.000 74.250
    –√––––
    720p FP 
    (Frame
    Packing)1280x72023.98 17.982 59.341
    –√––––
    24.00 18.000 59.400
    –√––––
    29.97 22.478 74.175
    –√––––
    30.00 22.500 74.250
    –√––––
    50.00 37.500 75.250
    –√––––
    59.94 44.715 74.406
    –√––––
    60.00 45.000 74.250
    –√––––
    1080p SBS 
    (Side-by-
    Side)1920x108023.98 26.978 74.175
    –√––––
    24.00 27.000 74.250
    –√––––
    29.97 33.716 74.175
    –√––––
    30.00 33.750 74.250
    –√––––
    50.00 56.250 148.500
    –√––––
    59.94 67.433 148.350
    –√––––
    60.00 67.500 148.500
    –√–––– 
    						
    All Runco manuals Comments (0)