Runco X 450d Projector User Manual
Have a look at the manual Runco X 450d Projector User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 123 Runco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
External Control Runco X-400d/X-450d Installation/Operation Manual 115 PREL IMINARY Remote Key Repeat (cont.) KRT W No 0 85 No 64 = Keypad Menu (used internally) 65 = Power Toggle (used internally) 66 = Enter Key Up (used internally) 67 = SRC 1 68 = SRC 2 69 = SRC 3 70 = SRC 4 71 = SRC 5 72 = SRC 6 73 = SRC 7 74 = SRC 8 75 = SRC 9 76 = SRC 10 77 = SRC 11 78 = SRC 12 79 = SRC 13 80 = SRC 14 81 = HDMI 5 82 = HDMI 6 83 = HDMI 7 84 = HDMI 8 85 = DisplayPort 86 = Auto Cinema Language LAN R/W No 0 9 No 0 = English 1 = French 2 = German 3 = Italian 4 = Spanish 5 = Portuguese 6 = Simplified Chinese 7 = Traditional Chinese 8 = Swedish 9 = Russian 10 = Japanese 11 = Korean Lens Home Position LHP W No N/A N/A No Action will be performed on any setting value Lamp Hours Reset LHR W No N/A N/A No Action will be performed on any setting value Lamp Hours LHS R No 0 (Note) No Max = 2,147,483,647 Image Alignment Left Middle x LMX R/W Yes -100 100 No Image Alignment Left Middle y LMY R/W Yes -100 100 No Lamp Life Notification Enable LNE R/W No 0 1 No 0 = Off; 1 = On Lamp Life Notification Hours LNH R/W Yes 100 10,000 No Logo LED Brightness LOG R/W Yes 0 31 No Lamp Power LPW R/W Yes -1 0 No -1 = 230W; 0 = 260W Table 6-1. Serial Commands (continued) SettingCommand CodeRead/ WriteInc/ DecMin ValueMax ValueString? Notes
External Control 116 Runco X-400d/X-450d Installation/Operation Manual PREL IMINARY Display Serial Number LSN R No N/A N/A Yes Model Name MDL R No N/A N/A Yes Memory Preset MMP R/W No 0 3 No 0 = ISF Night 1 = ISF Day 2 = Custom 1 3 = Custom 2 Memory Preset Copy MPC W No N/A N/A No Action will be performed on any setting value Memory Preset Paste MPP W No N/A N/A No Memory Preset Reset MPR W No 0 3 No 0 = ISF Night 1 = ISF Day 2 = Custom 1 3 = Custom 2 Memory Preset Save MPS W No 0 3 No Noise Filter NFL R/W Yes 0 10 No Calibration -> Input Color menu Noise Filter Offset NFO R/W Yes 0 10 No Picture menu Orientation ORI R/W No0 4 No 0 = Floor Front 1 = Ceiling Front 2 = Floor Rear 3 = Ceiling Rear 4 = Auto OSD Position Horizontal OSD R/W Yes 0 100 No Output Shift Height OSH R/W Yes -50 0 No Output Shift Left Right OSL R/W Yes -300 300 No OSD Message Enable OSM R/W No 0 1 No 0 = Off; 1 = On OSD Timer OST R/W Yes 0 60 No Values from 1-4 are not allowed; if increment or decrement is used, these values will be skipped. Output Shift Up Down OSU R/W Yes -200 200 No OSD Position Vertical OSV R/W Yes 0 100 No Output Shift Width OSW R/W Yes -50 0 No Overscan Mode OVM R/W No 0 1 No 0 = Zoom 1 = Crop Overscan OVS R/W Yes 0 20 No Table 6-1. Serial Commands (continued) SettingCommand CodeRead/ WriteInc/ DecMin ValueMax ValueString? Notes
External Control Runco X-400d/X-450d Installation/Operation Manual 117 PREL IMINARY Programmable Source Key [1 ... 14]P01 P02 P03 P04 P05 P06 P07 P08 P09 P10 P11 P12 P13 P14R/W No 0 15 No 0 = Composite 1 1 = Composite 2 2 = Composite 3 3 = Component 4 = HD 1 5 = HD 2 6 = SCART 7 = HDMI 1 8 = HDMI 2 9 = HDMI 3 10 = HDMI 4 11 = HDMI 5 12 = HDMI 6 13 = HDMI 7 14 = HDMI 8 15 = DisplayPort PCE Cyan X PCX R/W Yes -100 100 No PCE Cyan Y PCY R/W Yes -100 100 No Phase PHS R/W Yes 0 31 No PCE Magenta X PMX R/W Yes -100 100 No PCE Magenta Y PMY R/W Yes -100 100 No Periodic Notification Enable PNE R/W No 0 1 No 0 = Off; 1 = On Periodic Notification Months PNM R/W Yes 1 255 No Power PWR R/W No 0 1 No 0 = Off; 1 = On PCE Yellow X PYX R/W Yes -100 100 No PCE Yellow Y PYY R/W Yes -100 100 No Table 6-1. Serial Commands (continued) SettingCommand CodeRead/ WriteInc/ DecMin ValueMax ValueString? Notes
External Control 118 Runco X-400d/X-450d Installation/Operation Manual PREL IMINARY Input Name 1 Restore R01 W No N/A N/A No Action will be performed on any setting value Input Name 2 Restore R02 W No N/A N/A No Input Name 3 Restore R03 W No N/A N/A No Input Name 4 Restore R04 W No N/A N/A No Input Name 5 Restore R05 W No N/A N/A No Input Name 6 Restore R06 W No N/A N/A No Input Name 7 Restore R07 W No N/A N/A No Input Name 8 Restore R08 W No N/A N/A No Input Name 9 Restore R09 W No N/A N/A No Input Name 10 Restore R10 W No N/A N/A No Input Name 11 Restore R11 W No N/A N/A No Input Name 12 Restore R12 W No N/A N/A No Input Name 13 Restore R13 W No N/A N/A No Input Name 14 Restore R14 W No N/A N/A No Input Name 15 Restore R15 W No N/A N/A No Input Name 16 Restore R16 W No N/A N/A No Remote Code RMN R/W Yes 0 65535 No Image Alignment Right Middle x RMX R/W Yes -100 100 No Remote Network Control RNC R/W No 0 1 No 0 = Off; 1 = On Standby LED Enable SBL R/W No 0 1 No 0 = Off; 1 = On Splash Configure String 1 SC1 R/W No N/A N/A Yes 30 characters max Splash Configure String 2 SC2 R/W No N/A N/A Yes Splash Configure String 3 SC3 R/W No N/A N/A Yes Sidebar Color Blue SCB R/W Yes 0 255 No Sidebar Color Green SCG R/W Yes 0 255 No Screen SCN R/W No 0 1 No 0 = Screen 1 1 = Screen 2 Sidebar Color Red SCR R/W Yes 0 255 No Send Errors to Runco SER R/W No 0 1 No 0 = Off; 1 = On Sharpness Offset SHO R/W Yes -50 50 No Sharpness SHP R/W Yes -50 50 No Screen Masking Bottom SMB R/W Yes 0 200 No Screen Masking Test Pattern EnableSME R/W No 0 1 No 0 = Off; 1 = On Table 6-1. Serial Commands (continued) SettingCommand CodeRead/ WriteInc/ DecMin ValueMax ValueString? Notes
External Control Runco X-400d/X-450d Installation/Operation Manual 119 PREL IMINARY Screen Masking Left SML R/W Yes 0 200 No Screen Masking Test Pattern Mode EnableSMM R/W No 0 1 No 0 = Off; 1 = On Screen Masking Right SMR R/W Yes 0 200 No Screen Masking Top SMT R/W Yes 0 200 No Splash Enable SPE R/W No 0 1 No 0 = Off; 1 = On Splash Timer SPT R/W Yes 5 60 No Status STA RNo04No Sync Threshold STH R/W Yes 0 15 No Sleep Timer STM R/W No 0 5 No 0 = Off 1 = 30 Minutes 2 = 60 Minutes 3 = 90 Minutes 4 = 2 Hours 5 = 4 Hours Subnet Mask Byte 1 SU1 R/W Yes 0 255 No Subnet Mask Byte 2 SU2 R/W Yes 0 255 No Subnet Mask Byte 3 SU3 R/W Yes 0 255 No Subnet Mask Byte 4 SU4 R/W Yes 0 255 No System Reset SYS W No N/A N/A No Action will be performed on any setting value Table 6-1. Serial Commands (continued) SettingCommand CodeRead/ WriteInc/ DecMin ValueMax ValueString? Notes
External Control 120 Runco X-400d/X-450d Installation/Operation Manual PREL IMINARY Trigger 1 16:9 T11 R/W No 0 1 No 0 = Off; 1 = On Trigger 1 4:3 T12 R/W No 0 1 No Trigger 1 Letterbox T13 R/W No 0 1 No Trigger 1 VirtualWide T14 R/W No 0 1 No Trigger 1 Cinema T15 R/W No 0 1 No Trigger 1 Virtual Cinema T16 R/W No 0 1 No Trigger 1 Native T17 R/W No 0 1 No Trigger 2 16:9 T21 R/W No 0 1 No Trigger 2 4:3 T22 R/W No 0 1 No Trigger 2 Letterbox T23 R/W No 0 1 No Trigger 2 VirtualWide T24 R/W No 0 1 No Trigger 2 Cinema T25 R/W No 0 1 No Trigger 2 Virtual Cinema T26 R/W No 0 1 No Trigger 2 Native T27 R/W No 0 1 No Trigger 3 16:9 T31 R/W No 0 1 No Trigger 3 4:3 T32 R/W No 0 1 No Trigger 3 Letterbox T33 R/W No 0 1 No Trigger 3 VirtualWide T34 R/W No 0 1 No Trigger 3 Cinema T35 R/W No 0 1 No Trigger 3 Virtual Cinema T36 R/W No 0 1 No Trigger 3 Native T37 R/W No 0 1 No 3D Test Pattern Enable TDE R/W No 0 1 No 0 = Off; 1 = On 3D Mode TDM R/W No 0 4 No 0 = Auto 1 = Off 2 = Side-by-Side 3 = Top-and-Bottom 4 = Frame Packing 3D Reverse Eyes TDR R/w No 0 1 No 0 = Off; 1 = On Image Alignment Top Left x TLX R/W Yes -100 100 No Image Alignment Top Left y TLY R/W Yes -100 100 No 3D Test Pattern Mode Enable TME R/W No 0 1 No 0 = Off; 1 = On Image Alignment Top Middle x TMX R/W Yes -100 100 No Image Alignment Top Middle y TMY R/W Yes -100 100 No Tint Offset TNO R/W Yes -50 50 No Picture menu Tint TNT R/W Yes -50 50 No Calibration -> Input Image menu Table 6-1. Serial Commands (continued) SettingCommand CodeRead/ WriteInc/ DecMin ValueMax ValueString? Notes
External Control Runco X-400d/X-450d Installation/Operation Manual 121 PREL IMINARY Test Pattern Enable TPE R/W No 0 1 No 0 = Off; 1 = On Primary Test Pattern TPP R/W No 0 1 No 0 = Off; 1 = On Secondary Test Pattern TPS R/W No 0 1 No 0 = Off; 1 = On Tracking TRK R/W Yes -100 100 No Image Alignment Top Right x TRX R/W Yes -100 100 No Image Alignment Top Right y TRY R/W Yes -100 100 No Test Video TST R/W No 0 4 No 1 = Color Bars 1 2 = Full White 11 = Color Bars 2 12 = Gray Bars 13 = Focus 14 = Off 15 = Off (Restore OSD) 16 = Primary Alignment 17 = Secondary Alignment 18 = Dual Alignment 19 = 3D VFD Brightness VFD R/W Yes 0 4 No 0 = 0% 1 = 25% 2 = 50% 3 = 75% 4 = 100% Vertical Shift VSH W Yes 0 0 No Send (VSH+) or (VSH-) to adjust incrementally Zoom ZOM W Yes 0 0 No Send (ZOM+) or (ZOM-) to adjust incrementally Table 6-1. Serial Commands (continued) SettingCommand CodeRead/ WriteInc/ DecMin ValueMax ValueString? Notes
External Control 122 Runco X-400d/X-450d Installation/Operation Manual PREL IMINARY 6.2 Using Discrete IR CodesThe Dimension Digital Controller accepts commands in the form of IR signals that conform to the NEC protocol. Each Dimension Digital Controller remote control button has an NEC control code associated with it. You can use these codes to program a third-party, “universal” remote control unit to work with the Dimension Digital Controller. These third-party products usually come with a computer software application for this purpose. For more information, consult the documentation provided with the remote control unit. IR Command ProtocolThe IR control codes have the following characteristics: Each code consists of the following: leader pulse (a modulated pulse of 9 ms followed by a non-modulated pulse of 4.5 ms); address bits. The default address is 82 09 (0x2011, binary 00100000 00010001). To change it, select Remote Control from the Service menu and follow the steps given on page 87; data bits: eight (8) bits for the command followed by the logical inverse of the command; and end pulse (a modulated pulse of 0.56 ms, similar to the modulated pulse in the ‘0’ and ‘1’ bits).The end of the modulated pulse constitutes the end of the data transmission. The carrier frequency is 38 kHz, with the modulated pulses having a 33% duty cycle. Commands are sent at a maximum rate of 9 Hz. For example, here is the NEC control code for the ON button on the Dimension Digital Controller remote control unit (assuming the default address is used): Figure 6-1 shows the pulse train for this command. Figure 6-1. NEC Protocol Message Format ➤ Hex201101FE Binary 00100000 0001000100000001 11111110 Function Address Byte 1 Address Byte 2 CommandCommand (Logical Inverse) 9 ms 13.5 ms 27 ms 27 ms Address Byte 1 Leader Pulse Address Byte 2 Command Byte Command Byte (logical inverse) 001 000000001 0001 00000001 1 1 1 1 1 1 1 04.5 msEnd Pulse
External Control Runco X-400d/X-450d Installation/Operation Manual 123 PREL IMINARY IR Command List (Standard Mode) Table 6-2 lists the NEC control codes for the Dimension Digital Controller. Table 6-2. NEC Control Codes for the Dimension Digital Controller (Standard Mode) Remote Control Button NameAddressDataNEC Data From Remote (Note)Description ON 8209 1 0x201101FE Power on OFF (standby) 8209 2 0x201102FD Power off 16:9 8209 3 0x201103FC 16:9 aspect ratio 4:3 8209 4 0x201104FB 4:3 aspect ratio LETBOX 8209 5 0x201105FA Letterbox aspect ratio V-WIDE 8209 6 0x201106F9 VirtualWide aspect ratio CINEMA 8209 7 0x201107F8 Cinema aspect ratio V-CINE 8209 8 0x201108F7 Virtual Cinema aspect ratio NATIVE 8209 9 0x201109F6 Native aspect ratio 1 8209 10 0x20110AF5 Number Button 1 2 8209 11 0x20110BF4 Number Button 2 3 8209 12 0x20110CF3 Number Button 3 4 8209 13 0x20110DF2 Number Button 4 5 8209 14 0x20110EF1 Number Button 5 6 8209 15 0x20110FF0 Number Button 6 7 8209 16 0x201110EF Number Button 7 8 8209 17 0x201111EE Number Button 8 9 8209 18 0x201112ED Number Button 9 0 8209 19 0x201113EC Number Button 0 ISF DAY 8209 20 0x201114EB ISF Day memory preset ISF NIGHT 8209 21 0x201115EA ISF Night memory preset SCREEN 1 8209 22 0x201116E9 Selects “Screen 1” CUST 1 8209 23 0x201117E8 Custom 1 memory preset CUST 2 8209 24 0x201118E7 Custom 2 memory preset SCREEN 2 8209 25 0x201119E6 Selects “Screen 2” MENU 8209 26 0x20111AE5MENU EXIT 8209 27 0x20111BE4EXIT Up 8209 28 0x20111CE3 Up-Arrow ( ) Note: These codes assume that the default address of 8209 is used. If you change it to something other than 8209, you will need to modify these codes accordingly.
External Control 124 Runco X-400d/X-450d Installation/Operation Manual PREL IMINARY Right 8209 29 0x20111DE2 Right-Arrow ( ) Down 8209 30 0x20111EE1 Down-Arrow ( ) Left 8209 31 0x20111FE0 Left-Arrow ( ) ENTER 8209 32 0x201120DFENTER SRC 1 8209 33 0x201121DE Video Source 1 SRC 2 8209 34 0x201122DD Video Source 2 SRC 3 8209 35 0x201123DC Video Source 3 SRC 4 8209 36 0x201124DB Video Source 4 SRC 5 8209 37 0x201125DA Video Source 5 SRC 6 8209 38 0x201126D9 Video Source 6 SRC 7 8209 39 0x201127D8 Video Source 7 SRC 8 8209 40 0x201128D7 Video Source 8 SRC 9 8209 41 0x201129D6 Video Source 9 SRC 10 8209 42 0x20112AD5 Video Source 10 SRC 11 8209 43 0x20112BD4 Video Source 11 SRC 12 8209 44 0x20112CD3 Video Source 12 SRC 13 8209 43 0x20112BD4 Video Source 13 SRC 14 8209 46 0x20112ED1 Video Source 14 3D AUTO 8209 47 0x20112FD0 3D Mode = Auto 3D SBS 8209 48 0x201130CF 3D Mode = Side-by-Side 3D TAB 8209 49 0x201131CE 3D Mode = Top-and-Bottom 3D FP 8209 50 0x201132CD 3D Mode = Frame Packing STOFF 8209 65 0x201141BE Sets the sleep timer to Off ST30MIN 8209 66 0x201142BD Sets the sleep timer to 30 minutes ST60MIN 8209 67 0x201143BC Sets the sleep timer to 60 minutes ST90MIN 8209 68 0x201144BB Sets the sleep timer to 90 minutes ST2HRS 8209 69 0x201145BA Sets the sleep timer to 2 hours ST4HRS 8209 70 0x201146B9 Sets the sleep timer to 4 hours VIDEO 1 8209 71 0x201147B8 Composite video input 1 Table 6-2. NEC Control Codes for the Dimension Digital Controller (Standard Mode) (continued) Remote Control Button NameAddressDataNEC Data From Remote (Note)Description Note: These codes assume that the default address of 8209 is used. If you change it to something other than 8209, you will need to modify these codes accordingly.