Page 41
Runco CL-810 Series Owner’s Operating Manual 29 PREL IMINARY 4.1 Turning on the Power 1. Turn on your source components. 2. Turn on the main power switch at the rear of the projector. The POWER LED lights orange. The LAMP and TEMP LEDs light red briefly, then go out. 3. Press the ON button on the remote control to turn on the CL-810. The POWER LED flashes orange to indicate that it is warming up. 4. When the projector is ready for use, the POWER LED lights green. 5. “Searching...” appears on the...
Page 42
Operation 30 Runco CL-810 Series Owner’s Operating Manual PREL IMINARY 4.4 Lens Adjustments The CL-810 gives you a great deal of control over the picture size, position and focus. To access the motorized lens controls, use the FOCUS, ZOOM and LENS buttons on the remote control. FocusTo focus the projected image, press the FOCUS button, then use the left- and right-arrow buttons to adjust the focus. ZoomTo make the picture smaller (zoom out), press the ZOOM button, then use the left-arrow ( )...
Page 43
Operation Runco CL-810 Series Owner’s Operating Manual 31 PREL IMINARY 4.8 Selecting An Input Source When you turn on the CL-810, it switches to the last selected input and looks for a valid signal. Use these buttons on the remote control to select an input source directly. 4.9 Using Picture-In-Picture/ Picture-By-Picture (PIP/PBP) For PIP and PBP purposes, there are two groups of inputs separated by their display modes: • Video (SD) group: Video, S-Video and Component 1 inputs. •...
Page 44
Operation 32 Runco CL-810 Series Owner’s Operating Manual PREL IMINARY Figure 4-1. CL-810 OSD Menu Structure Option Reset Image Settings Yes / No Sleep Timer 0, 10, 20, 30 ... 180 minutes Lamp Hours (read only) OSD Timer 0, 3, 6, 9 ... 60 seconds OSD PositionHorizontal Vertical PC & HD Adjust (480p and higher-res. signals only)Auto Frequency 0, +1, +2, +3 ... +17 Phase 0, +1, +2, +3 ... +31 H. Position -30, -29 ... 0 ... +29, +30 V. Position -28, -27 ... 0 ... +29, +30 PIP/PBP Set Up (not available...
Page 45
Operation Runco CL-810 Series Owner’s Operating Manual 33 PREL IMINARY Main MenuThe Main Menu is the starting point for accessing all projector functions. (The Set Up and ISF Calibration menus are hidden and not accessible until you enter a passcode.) The active source is indicated by an arrow (>) to its left; in the example at left, Video is the active source. To select a different source, use the or button to highlight it and press ENTER or . Picture Adjustment Use the controls in the...
Page 46
Operation 34 Runco CL-810 Series Owner’s Operating Manual PREL IMINARY Although it may be possible to obtain satisfactory picture quality using the naked eye and regular program material, Runco recommends using the following calibration tools for best results: External test pattern source -- Sencore VP401 Multimedia Video Generator, Ovation Multimedia test DVD or equivalent. A blue filter (provided with many test DVDs), for color level and tint adjustments. Connect your test pattern source to the...
Page 47
Operation Runco CL-810 Series Owner’s Operating Manual 35 PREL IMINARY Contrast: On your external test pattern source, select a stepped, gray-bar pattern like the one shown in Figure 4-3. Figure 4-3. Typical Gray Bar Pattern for Adjusting Contrast Select Contrast from the Adjustment menu and press ENTER. Adjust the contrast to a point just below which the white rectangle starts to increase in size. Color Saturation: On your external test pattern source, select a color bar pattern like the one shown...
Page 48
Operation 36 Runco CL-810 Series Owner’s Operating Manual PREL IMINARY Select Color from the Adjustment menu and press ENTER. While looking at the color bar pattern through a blue filter, adjust the color saturation level until the outermost (gray and blue) color bars appear to be a single shade of blue: Tint: Tint or “hue” is essentially the ratio of red to green in the color portion of the image. When tint is decreased, the image appears redder; when it is increased the image appears greener. To...
Page 49
Operation Runco CL-810 Series Owner’s Operating Manual 37 PREL IMINARY Sharpness: “Sharpness” is the amount of high-frequency detail in the image. To adjust sharpness, select Sharpness from the Adjustment menu and press ENTER. On your external test pattern source, select a pattern like the one shown in Figure 4-5. Adjust as needed, looking for white edges around the transitions from black to gray and differently-sized lines in the “sweep” patterns at the top and bottom. Lower the sharpness setting...
Page 50
Operation 38 Runco CL-810 Series Owner’s Operating Manual PREL IMINARY Color Temperature: The CL-810 has six memory settings for Color Temperature. Four of these settings are factory set to default as follows: 0 -- Original lamp color temperature 1 -- 5400 kelvins 2 -- 6500 kelvins 3 -- 8500 kelvins 4 -- Custom 5 -- Custom Custom 4 and 5 memory are installer-adjustable and can be used to create custom settings. There are nine adjustable “white balance” parameters available for the...