Page 541
SM 5-175 B230/B237 Service Tables mode. 001 Dev. Motor Rotation: Display: Bk *ENG 002 Dev. Motor Rotation: Display: M *ENG 003 Dev. Motor Rotation: Display: C *ENG 004 Dev. Motor Rotation: Display: Y *ENG[0 to 1000 / 0 / 1 m/step] 005 Rotation Threshold *ENG [0 to 1000 / 1 / 1 m/step] 006 Pixel Coverage Sum: Bk *ENG 007 Pixel Coverage Sum: M *ENG 008 Pixel Coverage Sum: C *ENG 009 Pixel Coverage Sum: Y *ENG[0 to 65535 / 0 / 1 cm 2/step] 010 Required Area: Bk *ENG 011 Required Area:...
Page 542
B230/B237 5-176 SM Number: M 020 Pattern Generation Number: C *ENG 021 Pattern Generation Number: Y *ENG 022 Pattern Generation Number: Upper limit *ENG [0 to 255 / 0 / 1 time/step] 023 Toner Consumption Pattern Area *ENG [10 to 2550 / 320 / 10 cm2/step] 024 Supply Coefficient *ENG [0 to 2.55 / 1 / 0.01/step] 025 Job End Area Coefficient *ENG [0.1 to 25.5 / 1 / 0.1/step] 026 Job End Vb Coefficient *ENG [0 to 100 / 40 / 1%/step] 027 Job End Length *ENG [0 to 56 / 12 / 1mm/step] 028...
Page 543
SM 5-177 B230/B237 Service Tables 004 Toner End Recovery: Y *ENG 005 Vsg Adj. *ENG[0 or 1 / 0 / 1/step] 0: OFF. 1: ON 006 Developer Mixing *ENG[0 or 1 / 0 / 1/step] 0: OFF. 1: ON 007 Process Control *ENG[0 or 1 / 0 / 1/step] 0: OFF. 1: ON 008 MUSIC *ENG[0 or 1 / 0 / 1/step] 0: OFF. 1: ON 009 MUSIC (Skew Correction) *ENG[0 or 1 / 0 / 1/step] 0: OFF. 1: ON 010 Charge AC Control *ENG[0 or 1 / 0 / 1/step] 0: OFF. 1: ON 011 Blade Damage Prevention *ENG[0 or 1 / 0 / 1/step] 0: OFF....
Page 544
B230/B237 5-178 SM 002 Non-use Time Setting *ENG [0 to 1440 / 360 / 1 minute/step] 003 Temperature Range *ENG [0 to 99 / 10 / 1°C/step] 004 Relative Humidity Range *ENG [0 to 99 / 50 / 1 %RH/step] 005 Absolute Humidity Range *ENG [0 to 99 / 6 / 1 g/m3/step] [Non-use Time Process Control Setting] 3531 Adjusts the threshold for the process control at stand-by. When the current condition has changed by more than the values of these SPs when compared with the conditions at the previous...
Page 545
SM 5-179 B230/B237 Service Tables 007 C (Target Display) *ENG 008 Y (Target Display) *ENGDisplays the target development gamma for each color. [0 to 5 / 0.8 / 0.01 mg/cm2/kV /step] 009 Bk (Standard Target Set) *ENGDisplays the standard target development gamma for each color. [0 to 5 / 0.9 / 0.01 mg/cm 2/kV /step] 010 M (Standard Target Set) *ENG 011 C (Standard Target Set) *ENG 012 Y (Standard Target Set) *ENG[0 to 5 / 0.8 / 0.01 mg/cm 2/kV /step] 013 Environmental Correction...
Page 546
B230/B237 5-180 SM 003 Plain: C *ENG 004 Plain: Y *ENG 009 Thick 2 & FINE: Bk *ENG 010 Thick 2 & FINE: M *ENG 011 Thick 2 & FINE: C *ENG 012 Thick 2 & FINE: Y *ENG[0 to 700 / 550 / 1 -V/step] [Charge DC Control: Display] Plain: 138 mm/sec, Thick 2 and Fin: 77 mm/sec 3631 Displays the charge DC voltage adjusted with the process control for each line speed and color. 001 Plain: Bk *ENG 002 Plain: M *ENG 003 Plain: C *ENG 004 Plain: Y *ENG[0 to 2000 / 690 / 1 -V/step] 009 Thick 2...
Page 547
SM 5-181 B230/B237 Service Tables 002 Plain: M *ENG 003 Plain: C *ENG 004 Plain: Y *ENG [LD Power Control: Display] Plain: 138 mm/sec, Thick 2 and Fin: 77 mm/sec 3651 Displays the LD power adjusted for each environment. 001 Plain: Bk *ENG 002 Plain: M *ENG 003 Plain: C *ENG 004 Plain: Y *ENG[0 to 200 / 100 / 1 %/step] 009 Thick 2 & FINE: Bk *ENG 010 Thick 2 & FINE: M *ENG 011 Thick 2 & FINE: C *ENG 012 Thick 2 & FINE: Y *ENG[0 to 200 / 100 / 1 %/step] [HST Concentration...
Page 548
B230/B237 5-182 SM 002 Vt *ENG [0 to 5 / 2.5 / 0.1 V/step] 003 Sensitivity: HL *ENG [0 to 5 / 2.5 / 0.1 V/step] 004 Sensitivity: HM *ENG [0 to 5 / 1.3 / 0.1 V/step] 005 Sensitivity: ML *ENG [0 to 5 / 1.2 / 0.1 V/step] 006 Set Detection *ENG [0 to 5 / 1 / 0.1 V/step] 007 Without Developer *ENG [0 to 5 / 1.2 / 0.1 V/step] 008 With Developer *ENG [0 to 5 / 1.3 / 0.1 V/step] 009 Serial Number 1 *ENG 010 Serial Number 2 *ENG[0 to 255 / - / 1 V/step] 011 Adjustment: Vt *ENG [0 to 5 / 3...
Page 549
SM 5-183 B230/B237 Service Tables 008 With Developer *ENG [0 to 5 / 1.3 / 0.1 V/step] 009 Serial Number 1 *ENG 010 Serial Number 2 *ENG[0 to 255 / - / 1 V/step] 011 Adjustment: Vt *ENG [0 to 5 / 3 / 0.1 V/step] 012 Adjustment: Vtref *ENG [0 to 5 / 3 / 0.1 V/step] 013 Adjustment: Vtcnt *ENG [0 to 5 / 4 / 0.01 V/step] 014 Adjustment: Gamma *ENG [0 to 2.55 / 0 / 0.01 mg/cm2/kV /step] 015 Adjustment: Vcnt Result *ENG [0 to 9 / 9 / 1 /step] [HST Concentration Control: C] 3713...
Page 550
B230/B237 5-184 SM 014 Adjustment: Gamma *ENG [0 to 2.55 / 0 / 0.01 mg/cm2/kV /step] 015 Adjustment: Vcnt Result *ENG [0 to 9 / 9 / 1 /step] [HST Concentration Control: Y] 3714 Displays the factory settings of the yellow PCU. 001 Vcnt *ENG [0 to 5 / 4 / 0.1 V/step] 002 Vt *ENG [0 to 5 / 2.5 / 0.1 V/step] 003 Sensitivity: HL *ENG [0 to 5 / 2.5 / 0.1 V/step] 004 Sensitivity: HM *ENG [0 to 5 / 1.3 / 0.1 V/step] 005 Sensitivity: ML *ENG [0 to 5 / 1.2 / 0.1 V/step] 006 Set Detection...