Home > Ricoh > Printer > Ricoh B230 Service Manual

Ricoh B230 Service Manual

Here you can view all the pages of manual Ricoh B230 Service Manual. The Ricoh manuals for Printer are available online for free. You can easily download all the documents as PDF.

Page 541

 
SM 5-175 B230/B237 
Service 
Tables 
mode. 
001 Dev. Motor Rotation: 
Display: Bk *ENG
002 Dev. Motor Rotation: 
Display: M *ENG
003 Dev. Motor Rotation: 
Display: C *ENG
004 Dev. Motor Rotation: 
Display: Y *ENG[0 to 1000 / 0 / 1 m/step] 
005 Rotation Threshold  *ENG
[0 to 1000 / 1 / 1 m/step] 
006  Pixel Coverage Sum: Bk  *ENG
007  Pixel Coverage Sum: M  *ENG
008  Pixel Coverage Sum: C  *ENG
009  Pixel Coverage Sum: Y  *ENG[0 to 65535 / 0 / 1 cm
2/step] 
010 Required Area: Bk  *ENG
011 Required Area:...

Page 542

 
B230/B237 5-176  SM 
Number: M 
020 Pattern Generation 
Number: C *ENG
021 Pattern Generation 
Number: Y *ENG
022 Pattern Generation 
Number: Upper limit *ENG
[0 to 255 / 0 / 1 time/step] 
023 Toner Consumption 
Pattern Area *ENG
[10 to 2550 / 320 / 10 cm2/step] 
024 Supply Coefficient  *ENG
[0 to 2.55 / 1 / 0.01/step] 
025  Job End Area Coefficient  *ENG
[0.1 to 25.5 / 1 / 0.1/step] 
026  Job End Vb Coefficient  *ENG
[0 to 100 / 40 / 1%/step] 
027  Job End Length  *ENG
[0 to 56 / 12 / 1mm/step] 
028...

Page 543

 
SM 5-177 B230/B237 
Service 
Tables 
004  Toner End Recovery: Y  *ENG
005 Vsg Adj.  *ENG[0 or 1 / 0 / 1/step] 
0: OFF. 1: ON 
006 Developer Mixing  *ENG[0 or 1 / 0 / 1/step] 
0: OFF. 1: ON 
007 Process Control  *ENG[0 or 1 / 0 / 1/step] 
0: OFF. 1: ON 
008 MUSIC  *ENG[0 or 1 / 0 / 1/step] 
0: OFF. 1: ON 
009 MUSIC (Skew 
Correction) *ENG[0 or 1 / 0 / 1/step] 
0: OFF. 1: ON 
010 Charge AC Control  *ENG[0 or 1 / 0 / 1/step] 
0: OFF. 1: ON 
011 Blade Damage 
Prevention *ENG[0 or 1 / 0 / 1/step] 
0: OFF....

Page 544

 
B230/B237 5-178  SM 
002 Non-use Time Setting  *ENG
[0 to 1440 / 360 / 1 minute/step]  
003 Temperature Range  *ENG
[0 to 99 / 10 / 1°C/step] 
004  Relative Humidity Range  *ENG
[0 to 99 / 50 / 1 %RH/step] 
005  Absolute Humidity Range *ENG
[0 to 99 / 6 / 1 g/m3/step] 
 
[Non-use Time Process Control Setting] 
3531 Adjusts the threshold for the process control at stand-by.   
When the current condition has changed by more than the values of these SPs 
when compared with the conditions at the previous...

Page 545

 
SM 5-179 B230/B237 
Service 
Tables 
007  C (Target Display)  *ENG
008  Y (Target Display)  *ENGDisplays the target development gamma for 
each color.   
[0 to 5 / 0.8 / 0.01 mg/cm2/kV /step] 
009  Bk (Standard Target Set)  *ENGDisplays the standard target development 
gamma for each color.   
[0 to 5 / 0.9 / 0.01 mg/cm
2/kV /step] 
010  M (Standard Target Set)  *ENG
011  C (Standard Target Set)  *ENG
012  Y (Standard Target Set)  *ENG[0 to 5 / 0.8 / 0.01 mg/cm
2/kV /step] 
013 Environmental Correction...

Page 546

 
B230/B237 5-180  SM 
003 Plain: C  *ENG
004 Plain: Y  *ENG
009  Thick 2 & FINE: Bk  *ENG
010  Thick 2 & FINE: M  *ENG
011  Thick 2 & FINE: C  *ENG
012  Thick 2 & FINE: Y  *ENG[0 to 700 / 550 / 1 -V/step] 
 
[Charge DC Control: Display] 
Plain: 138 mm/sec, Thick 2 and Fin: 77 mm/sec 
3631 
Displays the charge DC voltage adjusted with the process control for each line 
speed and color. 
001 Plain: Bk  *ENG
002 Plain: M  *ENG
003 Plain: C  *ENG
004 Plain: Y  *ENG[0 to 2000 / 690 / 1 -V/step] 
009  Thick 2...

Page 547

 
SM 5-181 B230/B237 
Service 
Tables 
002 Plain: M  *ENG
003 Plain: C  *ENG
004 Plain: Y  *ENG
 
[LD Power Control: Display] 
Plain: 138 mm/sec, Thick 2 and Fin: 77 mm/sec 
3651 
Displays the LD power adjusted for each environment. 
001 Plain: Bk  *ENG
002 Plain: M  *ENG
003 Plain: C  *ENG
004 Plain: Y  *ENG[0 to 200 / 100 / 1 %/step] 
009  Thick 2 & FINE: Bk  *ENG
010  Thick 2 & FINE: M  *ENG
011  Thick 2 & FINE: C  *ENG
012  Thick 2 & FINE: Y  *ENG[0 to 200 / 100 / 1 %/step] 
 
[HST Concentration...

Page 548

 
B230/B237 5-182  SM 
002 Vt  *ENG
[0 to 5 / 2.5 / 0.1 V/step] 
003 Sensitivity: HL  *ENG
[0 to 5 / 2.5 / 0.1 V/step] 
004 Sensitivity: HM  *ENG
[0 to 5 / 1.3 / 0.1 V/step] 
005 Sensitivity: ML  *ENG
[0 to 5 / 1.2 / 0.1 V/step] 
006 Set Detection  *ENG
[0 to 5 / 1 / 0.1 V/step] 
007 Without Developer  *ENG
[0 to 5 / 1.2 / 0.1 V/step] 
008 With Developer  *ENG
[0 to 5 / 1.3 / 0.1 V/step] 
009  Serial Number 1  *ENG
010  Serial Number 2  *ENG[0 to 255 / - / 1 V/step] 
011 Adjustment: Vt  *ENG
[0 to 5 / 3...

Page 549

 
SM 5-183 B230/B237 
Service 
Tables 
008 With Developer  *ENG
[0 to 5 / 1.3 / 0.1 V/step] 
009  Serial Number 1  *ENG
010  Serial Number 2  *ENG[0 to 255 / - / 1 V/step] 
011 Adjustment: Vt  *ENG
[0 to 5 / 3 / 0.1 V/step] 
012 Adjustment: Vtref  *ENG
[0 to 5 / 3 / 0.1 V/step] 
013 Adjustment: Vtcnt  *ENG
[0 to 5 / 4 / 0.01 V/step] 
014 Adjustment: Gamma  *ENG
[0 to 2.55 / 0 / 0.01 mg/cm2/kV /step] 
015  Adjustment: Vcnt Result  *ENG
[0 to 9 / 9 / 1 /step] 
 
[HST Concentration Control: C] 
3713...

Page 550

 
B230/B237 5-184  SM 
014 Adjustment: Gamma  *ENG
[0 to 2.55 / 0 / 0.01 mg/cm2/kV /step] 
015  Adjustment: Vcnt Result  *ENG
[0 to 9 / 9 / 1 /step] 
 
[HST Concentration Control: Y] 
3714 
Displays the factory settings of the yellow PCU.   
001 Vcnt  *ENG
[0 to 5 / 4 / 0.1 V/step] 
002 Vt  *ENG
[0 to 5 / 2.5 / 0.1 V/step] 
003 Sensitivity: HL  *ENG
[0 to 5 / 2.5 / 0.1 V/step] 
004 Sensitivity: HM  *ENG
[0 to 5 / 1.3 / 0.1 V/step] 
005 Sensitivity: ML  *ENG
[0 to 5 / 1.2 / 0.1 V/step] 
006 Set Detection...
Start reading Ricoh B230 Service Manual