Page 501
SM 5-135 B230/B237 Service Tables (77 mm/s): 2nd Side 003 Paper Transfer: FINE: 1st Side *ENG 004 Paper Transfer: FINE: 2nd Side *ENGNot used 005-008 Adjusts the environment coefficient for each mode. When the environment is detected as HH, SP2851 is multiplied by these SP values. 005 Separation DC: Thick 1 (77 mm/s): 1st Side *ENG 006 Separation DC: Thick 1 (77 mm/s): 2nd Side: *ENG[10 to 250 / 80 / 5%/step] 007 Separation DC: FINE: 1st Side *ENG 008 Separation DC: FINE: 2nd Side *ENGNot...
Page 502
B230/B237 5-136 SM [Image Transfer Roller Brake Time] 2903 Adjusts the time when the image transfer belt motor reverses from normal rotation after job end. DFU 003 Plain *ENG 004 Thick 1 *ENG 005 Thick 2 & FINE *ENG[100 to 1500 / 500 / 10 msec/step] [OPC Drum Reverse Time] 2904 Adjusts the time for how long the image transfer belt motor reverses after job end. DFU 003 All *ENG [0 to 200 / 30 / 10 msec/step] [ACS Setting (FC to Bk)] 2907 Adjusts the threshold for moving away...
Page 503
SM 5-137 B230/B237 Service Tables [Motor Start Control] 2909 Not used 001 On *ENG[0 to 1 / 0 / 1 sheet/step] 0: normal, 1: synchro [Motor Stop Control] 2910 Not used 001 On *ENG[0 to 1 / 0 / 1 sheet/step] 0: normal, 1: synchro [Drum Stop Timing] OPC Drum Motor Stop Timing Adjustment 2911 Not used 001 Bk *ENG 002 MCY *ENG[0 to 360 / 30 / 6 deg/step] [Gear Phase Control Result] 2912 DFU 001 Bk - M *ENG [–180 to 180 / 0 / 1 deg/step] [Gear Phase Control] 2913 Enables...
Page 504
B230/B237 5-138 SM 001 Stop Delay: Open *ENG 002 Stop Delay: Close *ENGDFU [1 to 50 / 38 / 1 ms/step] 003 Open Execution *ENGOpens the shutter on the laser optics housing unit manually for test purposes. 004 Close Execution *ENGCloses the shutter on the laser optics housing unit manually for test purposes. 007 Presence *ENG Not used [GainAdjust] Gain Adjustment of OPC Bk Drum Motor 2915 DFU 001 154 mm/sec *ENG 002 138 mm/sec *ENG 003 115 mm/sec *ENG 004 77 mm/sec *ENG[0 or 1 /...
Page 505
SM 5-139 B230/B237 Service Tables 001 Voltage *ENG [0 to 7000 / 5000 / 10 –V/step] [SecondaryFB: Plain] 2931 Adjusts the upper limit voltage for the paper transfer roller. These SPs are only used for plain paper use in full color mode. 001 Limit Voltage: Division 1 *ENG [0 to 7000 / 6000 / 10 –V/step] 002 Limit Voltage: Division 2 *ENG [0 to 7000 / 5000 / 10 –V/step] [SecondaryFB: Thin] 2932 Adjusts the upper limit voltage for the paper transfer roller. These SPs are only used...
Page 506
B230/B237 5-140 SM [SecondaryFB: Thick 1] 2935 Adjusts the upper limit voltage for the paper transfer roller. These SPs are only used for thick 1 paper use in full color mode. 001 Limit Voltage: Division 1 *ENG [0 to 7000 / 6000 / 10 –V/step] 002 Limit Voltage: Division 2 *ENG [0 to 7000 / 5000 / 10 –V/step] [SecondaryFB: Thick 2] 2936 Adjusts the upper limit voltage for the paper transfer roller. These SPs are only used for thick 2 paper use in full color mode. 001 Limit Voltage:...
Page 507
SM 5-141 B230/B237 Service Tables used for special 3 paper use in full color mode. 001 Limit Voltage: Division 1 *ENG [0 to 7000 / 6000 / 10 –V/step] 002 Limit Voltage: Division 2 *ENG [0 to 7000 / 5000 / 10 –V/step] SP3-XXX (Process) 3011 [Process Cont. Manual Execution] 001 Normal Executes the normal process control manually (potential control). Check the result with SP3-325-001 and 3-012-001 after executing this SP. 002 Density Adjustment Executes the toner density adjustment...
Page 508
B230/B237 5-142 SM See the troubleshooting section for details. 001 History: Latest *ENG 002 Result: Latest 1 *ENG 003 Result: Latest 2 *ENG 004 Result: Latest 3 *ENG 005 Result: Latest 4 *ENG 006 Result: Latest 5 *ENG 007 Result: Latest 6 *ENG 008 Result: Latest 7 *ENG 009 Result: Latest 8 *ENG 010 Result: Latest 9 *ENG[ 11111111 t o 99999999 / - / 1/step] 3013 [T Sensor Initial Set: Execution] Developer Initialization Setting 001 Execution: ALL - 002 Execution: COL...
Page 509
SM 5-143 B230/B237 Service Tables meaning of each code. All colors are displayed. Values are displayed in the order Y C M Bk. e.g., 1 (Y) 2 (C) 1 (M) 1 (Bk): Initialization of Cyan failed but the others succeeded. 3015 [Forced Toner Supply] Forced Toner Supply ([Color]) 001 Execution: ALL - 002 Execution: COL (MCY) - 003 Execution: Bk - 004 Execution: M - 005 Execution: C - 006 Execution: Y - Executes the manual toner supply to the development unit. [Forced Toner Supply:...
Page 510
B230/B237 5-144 SM 004 Lower Threshold *ENG [0 to 5 / 0.5 / 0.01 V/step] 005 Number of Lower counter *ENG [0 to 99 / 10 / 1 time/step] 006 Upper Counter: Bk *ENG 007 Upper Counter: M *ENG 008 Upper Counter: C *ENG 009 Upper Counter: Y *ENG 010 Lower Counter: Bk *ENG 011 Lower Counter: M *ENG 012 Lower Counter: C *ENG 013 Lower Counter: Y *ENG[0 to 99 / 0/ 1 time/step] [TD Sensor Initial Set] Developer Initialization Setting 3021 Specifies the developer agitation time for each...