Page 531
SM 5-165 B230/B237 Service Tables [ID Sensor Detection Value: Vsgave] 3313 Not used 001 Vsgave reg: Bk *ENG 002 Vsgave reg: M *ENG 003 Vsgave reg: C *ENG 004 Vsgave reg: Y *ENG[0 to 5.5 / - / 0.01 V/step] 005-007 Not used 005 Vsgave dif: M *ENG 006 Vsgave dif: C *ENG 007 Vsgave dif: Y *ENG[0 to 5.5 / - / 0.01 V/step] 008-010 Not used 008 Vsgave TM (Front) *ENG 009 Vsgave TM (Center) *ENG 010 Vsgave TM (Rear) *ENG[0 to 5.5 / - / 0.01 V/step] 3321 [Vsg Adjustment: Execution]...
Page 532
B230/B237 5-166 SM 004 Vsg reg: Y *ENG 005 Vsg dif: M *ENG 006 Vsg dif: C *ENG 007 Vsg dif: Y *ENG[0 to 5.5 / - / 0.01 V/step] 008 Vsg TM (Front) *ENG 009 Vsg TM (Center) *ENG 010 Vsg TM (Rear) *ENG[0 to 5.5 / - / 0.01 V/step] 3323 [Vsg Adjustment Result: Ifsg] DFU 001 Ifsg: Bk *ENG 002 Ifsg: M *ENG 003 Ifsg: C *ENG 004 Ifsg: Y *ENG[0 to 50 / - / 0.1 mA/step] 005 Ifsg TM (Front) *ENG 006 Ifsg TM (Center) *ENG 007 Ifsg TM (Rear) *ENG[0 to 50 / - / 0.1 mA/step] 3324 [Vsg...
Page 533
SM 5-167 B230/B237 Service Tables [Vsg Adjustment Result] 3325 Displays the result of the Vsg adjustment. The displayed numbers mean the result of each sensor (sensor for Front, sensor for Bk, sensor for Cyan, sensor for Center, sensor for Magenta, sensor for Yellow and sensor for Rear). 001 Latest *ENG 002 Latest 1 *ENG 003 Latest 2 *ENG 004 Latest 3 *ENG 005 Latest 4 *ENG 006 Latest 5 *ENG 007 Latest 6 *ENG 008 Latest 7 *ENG 009 Latest 8 *ENG 010 Latest 9 *ENG[ 1111111 t o...
Page 534
B230/B237 5-168 SM 3362 [ID Sensor Sensitivity: Setting] DFU 001 K2: Upper *ENG [0 to 1 / 0.32 / 0.01 /step] 002 K2: Lower *ENG [0 to 1 / 0.22 / 0.01 /step] 003 K5: Upper *ENG [0 to 10 / 5 / 0.01 /step] 004 K5: Lower *ENG [0 to 10 / 0.5 / 0.01 /step] 005 Kn: Lower *ENG [0 to 1 / 0.1 / 0.01 /step] 006 Kn: Upper *ENG [0 to 1 / 1 / 0.01 /step] 007 K5 Edit Point *ENG [0 to 1 / 0.15 / 0.01 /step] 008 K5 Target Voltage *ENG [0 to 5 / 1.63 / 0.01 V/step] 009 K5 Approximate Method *ENG[0...
Page 535
SM 5-169 B230/B237 Service Tables 3363 [ID Pattern Timing Setting] DFU 001 Scan YCMBk *ENGAdjusts the detection timing for the process control pattern. [-500 to 500 / 13.7 / 1 mm/step] 002 Paper Transfer Release Start Ti m e *ENGAdjusts the timing when the paper transfer unit is kept away from the image transfer belt. [0 to 2500 / 0 / 1 msec/step] 003 Delay Time *ENGAdjusts the processing timing for the process control pattern. [0 to 2500 / 600 / 1 msec/step] 004 MUSIC Delay Time...
Page 536
B230/B237 5-170 SM 004 Fixed Rate: Y *ENG [Toner Supply Rate: Display] 3411 Displays the current toner supply rate. 001 Latest: Bk *ENG 002 Latest: M *ENG 003 Latest: C *ENG 004 Latest: Y *ENG[0 to 100 / - / 1 %/step] 3421 [Toner Supply Range] 001 Upper Limit: Bk *ENG 002 Upper Limit: M *ENG 003 Upper Limit: C *ENG 004 Upper Limit: Y *ENGAdjusts the toner supply rate during printing. [0 to 100 / 100 / 1%/step] 005 Minimum Supply Time: Bk *ENG 006 Minimum Supply Time: M *ENG...
Page 537
SM 5-171 B230/B237 Service Tables 3452 [Toner Supply Carry Over: Setting] DFU 001 Maximum: Bk *ENG 002 Maximum: M *ENG 003 Maximum: C *ENG 004 Maximum: Y *ENG[0 to 10000 / 1000 / 1 msec/step] [Process Control Target M/A] 3501 Adjusts the target M/A. 001 Maximum M/A: Bk *ENG 002 Maximum M/A: M *ENG 003 Maximum M/A: C *ENG[0 to 1 / 0.42 / 0.001 mg/cm 2/step] 004 Maximum M/A: Y *ENG [0 to 1 / 0.43 / 0.001 mg/cm2/step] [Image Quality Adj. Counter: Display] 3510 Displays the...
Page 538
B230/B237 5-172 SM [Execution Interval: Setting] 3511 Adjusts the threshold for each adjustment mode. 001 Job End: Potential Control: BW *ENG [0 to 2000 / 250 / 1 page/step] 002 Job End: Potential Control: FC *ENG [0 to 2000 / 100 / 1 page/step] 003 Interrupt: Potential Control: BW *ENG [0 to 2000 / 500 / 1 page/step] 004 Interrupt: Potential Control: FC *ENG [0 to 2000 / 200 / 1 page/step] 005 Initial: Potential Control: BW *ENG [0 to 2000 / 200 / 1 page/step] 006 Initial: Potential...
Page 539
SM 5-173 B230/B237 Service Tables JE: FC 025 Correction Coefficient 2: JE: FC *ENG [0 to 1 / 1 / 0.01/step] 026 Correction Coefficient 1: Interrupt: BW *ENG [0 to 1 / 0.1 / 0.01/step] 027 Correction Coefficient 2: Interrupt: BW *ENG [0 to 1 / 1 / 0.01/step] 028 Correction Coefficient 1: Interrupt: FC *ENG [0 to 1 / 0.25 / 0.01/step] 029 Correction Coefficient 2: Interrupt: FC *ENG [0 to 1 / 1 / 0.01/step] 030 Max. Number Correction Threshold *ENG [0 to 99 / 2 / 1/step] 031 Max. Number...
Page 540
B230/B237 5-174 SM 004 Hour *ENG [0 to 23 / 0 / 1/step] 005 Minute *ENG [0 to 59 / 0 / 1/step] [Environmental Display: Job End] 3514 Displays the environmental conditions for the last job. These are used for process control execution timing. 001 Temperature *ENG [-1280 to 1270 / 0 / 0.1°C/step] 002 Relative Humidity *ENG [0 to 1000 / - / 0.1%RH/step] 003 Absolute Humidity *ENG [0 to 1000 / - / 0.1 g/cm3/step] [Execution Interval: Display] 3515 Displays the current interval for...