Page 361
SM 4-121 B230/B237 Trouble shooting No. Sensor Name/ Sensor Board Name ActiveCN ConditionSymptom tray is not detected when paper is set. Detection Sensor Shorted Paper on the by-pass tray is detected when paper is not set. Open Jam C (Jam 18) S24 Fusing Entrance Sensor L CN283/B6 Shorted Jam C (Jam 1) Open Jam Z (Jam 27) S25 Duplex Entrance Sensor L CN283/B9 Shorted Jam Z (Jam 1) Open Jam Z (Jam 25) S26 Duplex Exit Sensor L CN283/B12 Shorted Jam Z (Jam 1) S27 TD Sensor -...
Page 362
B230/B237 4-122 SM No. Sensor Name/ Sensor Board Name ActiveCN ConditionSymptom cannot be detected when the waste toner bottle is nearly full. Open Waste toner bottle is not detected when the waste toner bottle is set. SW03 Waste Toner Bottle Set Switch L CN251/A4 Shorted Waste toner bottle is detected when the waste toner bottle is set. S33 Tray 2 Paper Size Switch L CN251/B8, B9, B10, B12 Open/ Shorted Paper size error S34 Temperature/ Humidity Sensor A CN286/1, 3Open/ Shorted...
Page 363
SM 4-123 B230/B237 Trouble shooting No. Sensor Name/ Sensor Board Name ActiveCN ConditionSymptom Open Paper overflow message is not displayed when the paper overflow condition still remains. S37 Paper Overflow Sensor L CN218/15 Shorted Paper overflow message is displayed when the paper overflow condition does not remain. S38 Original Width Sensor 1 A CN313/2 Open/ Shorted Original paper size cannot be detected. S39 Original Width Sensor 2 A CN313/5 S40 Original Length Sensor 1...
Page 364
B230/B237 4-124 SM No. Sensor Name/ Sensor Board Name ActiveCN ConditionSymptom Contact Sensor Shorted 4.7.2 BLOWN FUSE CONDITIONS Power Supply Unit Rating Fuse 115V 220V - 240V Symptom when turning on the main switch FU1 5A/250V 5A/250V 5VE power to the SIO and IOB not supplied. FU2 5A/250V 5A/250V No response. (5V power to the BICU and controller is not supplied.) FU3 5A/250V 5A/250V 5V power to the IOB and finisher is not supplied. FU4 10A/125V 10A/125V 24V power to the BICU...
Page 367
SM 5-1 B230/B237 Service Tables 5. SERVICE TABLES 5.1 SERVICE PROGRAM MODE ƒ Make sure that the data-in LED ( ) is not on before you go into the SP mode. This LED indicates that some data is coming to the machine. When the LED is on, wait for the copier to process the data. 5.1.1 ENTERING AND EXITING SERVICE PROGRAM MODE ƒ The Service Program Mode is for use by service representatives only. If this mode is used by anyone other than service representatives for any reason, data might be...
Page 368
B230/B237 5-2 SM SP Mode Button Summary Here is a short summary of the touch-panel buttons. Opens all SP groups and sublevels. Closes all open groups and sublevels and restores the initial SP mode display. Opens the copy window (copy mode) so you can make test copies. Press SP Mode (highlighted) in the copy window to return to the SP mode screen, Enter the SP code directly with the number keys if you know the SP number. Then press . (The required SP Mode number will be highlighted...
Page 369
SM 5-3 B230/B237 Service Tables normal operation. Press any Class 1 number to open a list of Class 2 SP modes. Press to scroll the show to the previous or next group. Press to scroll to the previous or next display in segments the size of the screen display (page). Press to scroll the show the previous or next line (line by line). Press to move the highlight on the left to the previous or next selection in the list. Switching Between SP Mode and Copy Mode for Test Printing 1. In the...
Page 370
B230/B237 5-4 SM ƒ Refer to the Service Tables for the range of allowed settings. 1. Do this procedure to enter a setting: ƒ Press to toggle between plus and minus and use the keypad to enter the appropriate number. The number you enter writes over the previous setting. ƒ Press to enter the setting. (The value is not registered if you enter a number that is out of range.) ƒ Press “Yes” when you are prompted to complete the selection. 2. If you need to perform a test print, press...