Page 391
SM 5-25 B230/B237 Service Tables [Charge AC Current: ML] Charge Roller AC Current Adjustment for MM (Color) 2008 Displays/sets the AC current target of the charge roller for ML environment (Meddle temperature and Low humidity). DFU 001 Environmental Target: Bk *ENG [0 to 3000 / 1040 / 10 μA/step] 002 Environmental Target: M *ENG 003 Environmental Target: C *ENG[0 to 3000 / 1030 / 10 μA/step] 004 Environmental Target: Y *ENG [0 to 3000 / 1070 / 10 μA/step] [Charge AC Current: MM]...
Page 392
B230/B237 5-26 SM [Charge AC Current: HH] Charge Roller AC Current Adjustment for HH (Color) 2011 Displays/sets the AC current target of the charge roller for HH environment (High temperature and High humidity). DFU 001 Environmental Target: Bk *ENG [0 to 3000 / 940 / 10 μA/step] 002 Environmental Target: M *ENG 003 Environmental Target: C *ENG[0 to 3000 / 930 / 10 μA/step] 004 Environmental Target: Y *ENG [0 to 3000 / 960 / 10 μA/step] 2012 [Charge Output Control] 001 AC Voltage...
Page 393
SM 5-27 B230/B237 Service Tables 1: LL, 2: ML, 3: MM, 4: MH, 5: HH 003 Absolute Humidity: Threshold 1 *ENGChanges the humidity threshold between LL and ML. [0 to 100 / 4.3 / 0.01 g/m 3/step] 004 Absolute Humidity: Threshold 2 *ENGChanges the humidity threshold between ML and MM. [0 to 100 / 11 . 3 / 0.01 g/m 3/step] 005 Absolute Humidity: Threshold 3 *ENGChanges the humidity threshold between MM and MH. [0 to 100 / 18.0 / 0.01 g/m 3/step] 006 Absolute Humidity: Threshold 4...
Page 394
B230/B237 5-28 SM [Color Registration Correction] FA 2101 These values are the parameters for the automatic line position adjustment and are adjusted at the factory. However, you must input a value for SP2101-001 after replacing the laser optics housing unit. For details, see Laser Optics Housing Unit in the Replacement and Adjustment section. The value should be provided with the new laser optics housing unit. 001 Main Dot: Bk *ENG 002 Main Dot: M *ENG 003 Main Dot: C *ENG 004...
Page 395
SM 5-29 B230/B237 Service Tables 006 Main Mag.: Low Speed: M *ENG 007 Main Mag.: High Speed: C *ENG 008 Main Mag.: Medium Speed: C *ENG 009 Main Mag.: Low Speed: C *ENG 010 Main Mag.: High Speed: Y *ENG 011 Main Mag.: Medium Speed: Y *ENG 012 Main Mag.: Low Speed: Y *ENG 2103 [Erase Margin Adjustment] (Area, Paper Size) Adjusts the erase margin by changing the activation timing of the registration clutch. 001 Lead Edge Width *ENG 002 Trail. Edge Width *ENG[0 to 9.9 / 4.2 / 0.1...
Page 396
B230/B237 5-30 SM 2105 [LD Power Adj.] (Process Speed, Color) Displays the LD power of each color for each process speed. Each LD power setting is decided by process control. 001 High Speed: Bk *ENG 002 High Speed: M *ENG 003 High Speed: C *ENG 004 High Speed: Y *ENG 005 Middle Speed: Bk *ENG 006 Middle Speed: M *ENG 007 Middle Speed: C *ENG 008 Middle Speed: Y *ENG 009 Low Speed: Bk *ENG 010 Low Speed: M *ENG 011 Low Speed: C *ENG 012 Low Speed: Y...
Page 397
SM 5-31 B230/B237 Service Tables 002 Shading Correction Flag *ENG [0 or 1 / 1 / 1 /step] [Test Pattern] 2109 Generates the test pattern using COPY Window tab in the LCD. 003 Pattern Selection - [0 to 23 / 0 / 1/step] 0 None 1: 1-dot line pattern (Vertical) 2: 2-dot line pattern (Vertical) 3: 1-dot line pattern (Horizontal) 4: 2-dot line pattern (Horizontal) 5: 1-dot grid pattern (Vertical) 6: 1-dot grid pattern (Horizontal) 7: 1-dot grid pattern (Fine) 8: 1-dot grid pattern...
Page 398
B230/B237 5-32 SM 007 Density: M - 008 Density: C - 009 Density: Y - pattern. [0 to 15 / 15 / 1 /step] 0: Lightest density 15: Darkest density 2111 [Forced Line Position Adj.] 001 Mode a - Executes the fine line position adjustment twice. If this SP is not completed (NG is displayed), do SP2111-003 first and then try this SP again. 002 Mode b - Executes the fine line position adjustment once. If this SP is not completed, do SP2111-003 first and then try this SP again. 003...
Page 399
SM 5-33 B230/B237 Service Tables 001 Pulse: M *ENG 002 Pulse: C *ENG 003 Pulse: Y *ENG[–100 to 100 / 0 / 1 pulse/step] 2118 [Skew Adjustment] 001 Pulse: M *ENG 002 Pulse: C *ENG 003 Pulse: Y *ENGChanges the current skew adjustment values to the values specified with SP2117. These SPs must be used when a new laser optics housing unit is installed or when SC285 occurs. For details, see Laser Optics Housing Unit in the Replacement and Adjustment section. [Skew Adjustment...
Page 400
B230/B237 5-34 SM 005 Front *ENG 006 Center *ENG 007 Rear *ENG [ID Sensor Check Result: Ave.] DFU 2141 Displays the average result values of the ID sensor check. Bk, M, C, Y: ID sensors for the process control Front, Center, Rear: ID sensors for the automatic line position adjustment 001 Bk *ENG 002 M *ENG 003 C *ENG 004 Y *ENG 005 Front *ENG 006 Center *ENG 007 Rear *ENG[0 to 5 / 0 / 0.01V/step] [ID Sensor Check Result] DFU 2142 Displays the maximum result values of the ID...