Bit Switches SM 91 B786 B786 Fax Option 0 1 0 1 12.0 Kbps 0 1 1 0 14.4 Kbps 0 1 1 1 16.8 Kbps 1 0 0 0 19.2 Kbps 1 0 0 1 21.6 Kbps 1 0 1 0 24.0 Kbps 1 0 1 1 26.4 Kbps 1 1 0 0 28.8 Kbps 1 1 0 1 31.2 Kbps 1 1 1 0 33.6 Kbps Modem setting for reception Sets the modem type for reception. The default is 0100 (V27ter, V29, V17). Bit 7 Bit 6 Bit 5 Bit 4 0 0 0 1 V27ter 0 0 1 0 V27ter, V29 0 0 1 1 V27ter, V29, V33 (invalid) 0 1 0 0 V27ter, V29, V17 0 1 0 1...
Page 1042
Bit Switches B786 92 SM 1: Hang up after transmitting DCN 4 Number of times for training 0: 1 time, 1: 2 times Selects the number of times training is done at the same bit rate. 5 Space CSI transmission setting at no CSI registration 0: Not transmitted, 1: Transmitted When 0 is selected, frame data is enabled. When 1 is selected, the transmitted data is all spaces. 6-7 Not used Do not change these settings. IP Fax Switch 08 [SP No. 1-111-009] No. FUNCTION COMMENTS 0-1 T1 timer...
Page 1043
NCU Parameters SM 93 B786 B786 Fax Option 4.4 NCU PARAMETERS The following tables give the RAM addresses and the parameter calculation units that the machine uses for ringing signal detection and automatic dialing. The factory settings for each country are also given. Most of these must be changed by RAM read/write (SP2- 102), but some can be changed using NCU Parameter programming (SP2-103, 104 and 105); if SP2-103, 104 and 105 can be used, this will be indicated in the Remarks column. The RAM...
Page 1044
NCU Parameters B786 94 SM Address Function Spain 14 0E Czech 35 23 Israel 15 0F Poland 36 24 Address Function Unit Remarks 680501 Line current detection time 680502 Line current wait time 680503 Line current drop detect time 20 ms Line current detection is disabled. Line current is not detected if 680501 contains FF. 680504 PSTN dial tone frequency upper limit (high byte) 680505 PSTN dial tone frequency upper limit (low byte) Hz (BCD) If both addresses contain...
Page 1045
NCU Parameters SM 95 B786 B786 Fax Option Address Function Unit Remarks 680513 PSTN busy tone frequency upper limit (high byte) 680514 PSTN busy tone frequency upper limit (low byte) Hz (BCD) If both addresses contain FF(H), tone detection is disabled. 680515 PSTN busy tone frequency lower limit (high byte) 680516 PSTN busy tone frequency lower limit (low byte) Hz (BCD) If both addresses contain FF(H), tone detection is disabled. 680517 PABX dial tone frequency upper limit (high byte)...
Page 1046
NCU Parameters B786 96 SM Address Function Unit Remarks 680527 PABX busy tone frequency upper limit (low byte) detection is disabled. 680528 PABX busy tone frequency lower limit (high byte) 680529 PABX busy tone frequency lower limit (low byte) Hz (BCD) If both addresses contain FF(H), tone detection is disabled. 68052A Busy tone ON time: range 1 68052B Busy tone OFF time: range 1 68052C Busy tone ON time: range 2 68052D Busy tone OFF time: range 2 68052E Busy tone ON time: range 3...
Page 1047
NCU Parameters SM 97 B786 B786 Fax Option Address Function Unit Remarks 68053A International dial tone reset time (HIGH) 68053B International dial tone continuous tone time 68053C International dial tone permissible drop time Belgium: See Note 2. 68053D International dial wait interval (LOW) 68053E International dial wait interval (HIGH) - 68053F Country dial tone upper frequency limit (HIGH) 680540 Country dial tone upper frequency limit (LOW) If both addresses contain FF(H), tone...
Page 1048
NCU Parameters B786 98 SM Address Function Unit Remarks 68054D Time between final OHDI relay closure and DO relay opening or closing 1 ms See Notes 3, 6 and 8. SP2-103-015 (parameter 14). This parameter is only valid in Europe. 68054E Minimum pause between dialed digits (pulse dial mode) See Note 3 and 8. SP2- 103-016 (parameter 15). 68054F Time waited when a pause is entered at the operation panel 20 ms SP2-103-017 (parameter 16). See Note 3. 680550 DTMF tone on time SP2-103-018...
Page 1049
NCU Parameters SM 99 B786 B786 Fax Option Address Function Unit Remarks 68055B International dial access code (High) 68055C International dial access code (Low) BCD For a code of 100: 68055B - F1 68055C - 00 68055D PSTN access pause time 20 ms This time is waited for each pause input after the PSTN access code. If this address contains FF[H], the pause time stored in address 68054F is used. Do not set a number more than 7 in the UK. 68055E Progress tone detection level, and...
Page 1050
NCU Parameters B786 100 SM Address Function Unit Remarks (parameter 07). 680578 Minimum required length of the second and subsequent rings 20 ms SP2-103-009 (parameter 08). 680579 Ringing signal detection reset time (LOW) SP2-103-010 (parameter 09). 68057A Ringing signal detection reset time (HIGH) 20 ms SP2-103-011 (parameter 10). 68057B to 680580 Not used - Do not change the settings. 680581 Interval between dialing the last digit and switching the Oh relay over to the external...