Service Tables 
SM 41 B786 
B786 
Fax Option 
001 – 016  00 – 0F Not used (Do not change the bit switches) 
IP fax Switch 
111  
001 – 016  00 – 0F Change the bit switches for optional IP fax 
parameters  
 Bit Switches 
4.2.2  SP2-XXX (RAM DATA) 
2 Mode No.  Function 
RAM Read/Write 
101 
001  Change RAM data for the fax board directly. 
 Service RAM Addresses 
Memory Dump 
001 G3-1 Memory 
Dump Print out RAM data for the fax board.  Service RAM Addresses 
002 G3-2 Memory 
Dump Print out RAM data for...

Page 992

Service Tables 
B786 42  SM 
000    Enter the fax unit’s serial number. 
PSTN-1 Port Settings 
001 Select Line Select the line type setting for the G3-1 line. If 
the machine is installed on a PABX line, select 
“PABX”, “PABX(GND)” or “PABX(FLASH)”. 
002 PSTN Access 
Number Enter the PSTN access number for the  
G3-1 line. 
103 
003 Memory Lock 
Disabled Not used 
PSTN-2 Port Settings 
001 Select Line Select the line setting for the G3-2 line. If the 
machine is installed on a PABX line, select 
“PABX”,...

Page 993

Service Tables 
SM 43 B786 
B786 
Fax Option 
IPFAX Port Settings 
001  H323 Port  Sets the H323 port number. 
002  SIP Port  Sets the SIP port number. 
003  RAS Port  Sets the RAS port number. 
004  Gatekeeper port  Sets the Gatekeeper port number. 
005  T.38 Port  Sets the T.38 port number. 
006  SIP Server Port  Sets the SIP port number. 
107 
007 IPFAX Protocol 
Priority Select H323 or SIP. 
FAX SW 201 
001 – 032  00 – 1F   
4.2.4  SP4-XXX (ROM VERSIONS) 
4 Mode No.  Function 
101  001  FCU ROM...

Page 994

Service Tables 
B786 44  SM 
000 Resets the bit switches and user parameters, user data in 
the SRAM and files in the SAF memory. 
Initialize All  Bit  Switches 105 
000  Initializes all the current bit switch settings. 
Initialize Security Bit Switches 
106 
000 Initializes only the security bit switches. If you select 
automatic output/display for the user parameter switches, 
the security settings are initialized. 
4.2.6 SP6-XXX (REPORTS) 
6 Mode No.  Function 
System Parameter List 
101 
000 - Touch...

Page 995

Service Tables 
SM 45 B786 
B786 
Fax Option 
004  Dch Link Layer 
005  Dch +Bch 2 
006  Bch 2 Link Layer 
All Files print out 
105 
000 - Prints out all the user files in the SAF 
memory, including confidential messages.  
ƒ  Do not use this function, unless the 
customer is having trouble printing 
confidential messages or recovering 
files stored using the memory lock 
feature. 
Journal Print out 
001 All Journals The machine prints all the communication 
records on the report. 106 
002 Specified Date...

Page 996

Service Tables 
B786 46  SM 
002 1 Communication Prints the protocol dump list of the last 
communication for the IP fax line. 
 
4.2.7  SP7-XXX (TEST MODES) 
These are the test modes for PTT approval. 
7 Function 
101 G3-1 Modem Tests 
102 G3-1 DTMF Tests 
103 Ringer Test 
104  G3-1 V34 (S2400baud) 
105  G3-1 V34 (S2800baud) 
106  G3-1 V34 (S3000baud) 
107  G3-1 V34 (S3200baud) 
108  G3-1 V34 (S3429baud) 
109 Recorded Message Test 
110 G3-2 Modem Tests 
111  G 3 - 2  D T M F  Te s t s  
112  G3-2 V34...

Page 997

Service Tables 
SM 47 B786 
B786 
Fax Option 
125  IG3-1 DTMF Tests - Not used 
126  IG3-1 V34 (S2400baud) - Not used 
127  IG3-1 V34 (S2800baud) - Not used 
128  IG3-1 V34 (S3000baud) - Not used 
129  IG3-1 V34 (S3200baud) - Not used 
130  IG3-1 V34 (S3429baud) - Not used 
131  IG3-2 Modem Tests - Not used 
132  IG3-2 DTMF Tests - Not used 
133  IG3-2 V34 (S2400baud) - Not used 
134  IG3-2 V34 (S2800baud) - Not used 
135  IG3-2 V34 (S3000baud) - Not used 
136  IG3-2 V34 (S3200baud) - Not used 
137...

Page 998

Bit Switches 
B786 48  SM 
4.3 BIT SWITCHES 
 
ƒ  Do not adjust a bit switch or use a setting that is described as “Not used”, as this 
may cause the machine to malfunction or to operate in a manner that is not 
accepted by local regulations. Such bits are for use only in other areas, such as 
Japan. 
 
ƒ  Default settings for bit switches are not listed in this manual. Refer to the System 
Parameter List printed by the machine. 
4.3.1 SYSTEM SWITCHES 
System Switch 00 [SP No. 1-101-001] 
No FUNCTION...

Page 999

Bit Switches 
SM 49 B786 
B786 
Fax Option 
So, the actual rx level is 256/-16 = -16 dB 
3 Not used  Do not change this setting. 
4 Line error mark print 
0: OFF, 1: ON (print) When 1 is selected, a line error mark is printed 
on the printout if a line error occurs during 
reception. 
5 G3/G4 communication 
parameter display 
0: Disabled 
1: Enabled This is a fault-finding aid. The LCD shows the key 
parameters (see below). This is normally disabled 
because it cancels the CSI display for the user. 
Be...

Page 1000

Bit Switches 
B786 50  SM 
Always enabled  (1,1): At any time, an RDS system can access the 
machine. 
 
System Switch 03 [SP No. 1-101-004] 
No FUNCTION COMMENTS 
0-7 Length of time that RDS is 
temporarily switched on when 
bits 6 and 7 of System Switch 
02 are set to “User selectable”00 - 99 hours (BCD). 
This setting is only valid if bits 6 and 7 of System 
Switch 02 are set to “User selectable”. 
The default setting is 24 hours. 
 
System Switch 04 [SP No. 1-101-005] 
No FUNCTION COMMENTS 
0-2 Not...