Page 51
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 51 8.1.2 Comprehensive Structured Report IOD Table 70 IOD OF CREATED COMPREHENSIVE STRUCTURED REPORT SOP INSTANCES IE Module Reference Presence of Module Patient Patient Table 71 ALWAYS Study General Study Table 72 ALWAYS Patient Study Table 73 ALWAYS Series SR Document Series Table 84 ALWAYS Equipment General Equipment Table 75 ALWAYS Document SR Document General Table 85 ALWAYS SR Document Content Table 86...
Page 52
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 52 Attribute Name Tag VR Value Presence of Value Source Referring Physician’s Name (0008,0090) PN Only Last, First and Middle names from MWL, sent as “Last, First, Middle” in the Last name field; or PDE input. VNAP MWL/ USER Study ID (0020,0010) SH MWL Requested Procedure ID (0040,1001) or auto-generated ALWAYS MWL/ AUTO Accession Number (0008,0050) SH Same attribute of MWL or user PDE input. VNAP MWL/ USER...
Page 53
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 53 Attribute Name Tag VR Value Presence of Value Source Performing Physician’s Name (0008,1050) PN PDE entry (Performed by) or mapped from MWL Scheduled Performing Physician’s Name. If the user does not enter a value, this tag is not sent. VNAP/ANAP MWL/ USER Series Description (0008,103E) LO From PDE “Indication” field VNAP USER Operator’s Name (0008,1070) PN Same as Performing...
Page 54
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 54 Table 76-a IMAGE PLANE MODULE FOR SINGLE AND MULTI-FRAME 2D IMAGES Attribute Name Tag VR Value Presence of Value Source Pixel Spacing (0028,00300) DS Physical distance in the patient between the center of each pixel, specified by a numeric pair – adjacent row spacing (delimiter) adjacent column spacing in mm ANAP SETUPS Table 77 IMAGE PIXEL MODULE OF CREATED US OR US MULTIFRAME SOP INSTANCES Attribute Name...
Page 55
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 55 Attribute Name Tag VR Value Presence of Value Source Pixel Representation (0028,0103) US “0” pixels ar e Unsigned integers ALWAYS AUTO Pixel Data (7FE0,0010) OW / OB The pixel data of the DICOM image. ALWAYS AUTO Planar Configuration (0028,0006) US Must be present when image is RGB. Value is “0”. Palette Color Images: Not present RGB Images: Always zero (color-by-pixel) YBR: Images: Always zero...
Page 56
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 56 Attribute Name Tag VR Value Presence of Value Source Blue Palette Color Lookup Table Descriptor (0028,1103) US Used only for 2D and REPORT acquired as image. B&W stills & loops: 256, 0, 16 Color stills & loops: 0, 0, 16 REPORT (acquired as image): xx, 0, 16 where ‘xx’ is a variable...
Page 57
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 57 Table 79 MULTI-FRAME MODULE OF CREATED US MULTIFRAME SOP INSTANCES Attribute Name Tag VR Value Presence of Value Source Number of Frames (0028,0008) IS # of frames in object ANAP AUTO Frame Increment Pointer (0028,0009) AT Configurable by the user in DICOM Setup. If the user selects a loop timing preference where each frame in a loop has the same duration then Frame Increment Pointer takes the value...
Page 58
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 58 Attribute Name Tag VR Value Presence of Value Source >Reference Pixel Y0 (0018,6022) SL The Y pixel value ANAP AUTO >Physical Units X Direction (0018,6024) US Enumerated Value. 2D Image = 0003H = CM M-mode / Doppler / ECG = 0004H = SEC ALWAYS AUTO >Physical Units Y Direction (0018,6026) US Enumerated Value. ECG Region = 0000H = NONE 2D Image = 0003H = CM...
Page 59
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 59 Attribute Name Tag VR Value Presence of Value Source Ultrasound Color Data Present (0028,0014) US 0 or 1 ALWAYS AUTO Stage Name (0008,2120) SH REST, PEAK, POST, IMPOST, BASE, LOW, user defined ANAP AUTO Stage Number (0008,2122) IS 1-n ANAP AUTO View Name (0008,2127) SH LAX, SAX, AP4, AP2, AP3, user defined ANAP AUTO View Number (0008,2128) IS 1-n ANAP AUTO Number of Event Timers (0008,2129) IS 1-n...
Page 60
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 60 8.1.5 Comprehensive Structured Report Modules Table 84 SR DOCUMENT SERIES MODULE OF CREAT ED COMPREHENSIVE SR SOP INSTANCES Attribute Name Tag VR Value Presence of Value Source Modality (0008,0060) CS“SR” ALWAYS AUTO Series Instance UID (0020,000E) UI Auto-generated ALWAYS AUTO Series Number (0020,0011) IS A number unique within the Study starting with 2. ALWAYS AUTO Referenced Performed Procedure Step...