HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A  Page 21 
4.2.1.4.1.3  SOP Specific Conformance for  Storage Commitment Push Model SOP Class 
4.2.1.4.1.3.1 Storage  Commitment Notifications (N-EVENT-REPORT) 
Upon receipt of an N-EVENT-REPORT the timer associated with the Transaction UID will be canceled. 
Table 14 summarizes the behavior of  Storage AE when receiving Event Types within the N-EVENT-REPORT.  
Table 15 summarizes the reasons for returning specif ic status codes in an...

Page 22

 
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A  Page 22 
Table 22 
DICOM IMPLEMENTATION CLASS AND VERSION FOR AE WORKFLOW 
Implementation Class UID  1.3.46.670589.14.3000.300 
Implementation Version Name  HD7_300 
 
4.2.2.3 Association Initiation Policy 
4.2.2.3.1 Activity – Worklist Update 
4.2.2.3.1.1 Description and Sequencing of Activities  
Worklist queries for Modality (U S) or  modalities may be initiated by the  user or will occur at a preset interval set 
as one of the...

Page 23

 
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A  Page 23 
4.2.2.3.1.2  Proposed Presentation Contexts 
HD7/HD7XE 3.0 will propose Presentation Contexts as shown in the following table: 
Table 23 
PROPOSED PRESENTATION CONTEXTS  FOR ACTIVITY WORKLIST UPDATE 
Presentation Context Table 
Abstract Syntax  Transfer Syntax  
 
Role   
Ext. 
Neg. 
Name  UID Name List  UID List 
Modality Worklist 
Information Model – 
FIND 1.2.840.10008.5.1.
4.31 
Implicit VR Little Endian 
Explicit VR Little...

Page 24

 
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A  Page 24 
Table 25 summarizes the behavior of HD7/HD7XE 3.0 during communication failure.   
Table 25 
MODALITY WORKLIST COMMUNICATION FAILURE BEHAVIOR 
Exception Behavior 
Timeout  Same as Service Status “Refused” in the table above.
Association aborted by the SCP or network layersSame as Service Status “Refused” in the table above.
 
Table 26 describes the HD7/HD7XE 3.0 Worklist Matching Keys and requested attributes.   
Unexpected...

Page 25

 
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A  Page 25 
Module Name 
 Attribute Name 
Tag VR M RD IOD 
Visit Admission  
  Current Patient Location10   
(0038,0300)  
LO  
 x  
x   
 
Patient Identification
 
 Patient’s Name 
 Patient ID
 
  Other Patient IDs11   
(0010,0010) 
(0010,0020) 
(0010,1000)  
PN 
LO 
LO  
 
 
 
x
x
x  
x
x    
x 
x 
x 
Patient Demographic  
  Patient’s Birth Date12 
  Patient’s Birth Time12 
 Patient’s Sex13 
 Patient’s Age14 
 Patient Size15 
 Ethnic...

Page 26

 
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A  Page 26 
4 Scheduled Procedure Step Location sets the “Loc ation: field in the Patient Selection Screen. 
5  Requested Procedure Description value is se t in the “Description” field of the Patient 
Selection screen and “Study Description” of  the Patient ID screen. Manual entry to Study 
Description field is also sent in Image and MPPS messages. 
6  May be used to set “Indication” field on Patient Selection screen. 1
st choice,...

Page 27

 
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A  Page 27 
Workflow
AEDepartmentScheduler
1 Open Association
2 N-CREATE (MPPS) - IN PROGRESS
3 Close Association
7 Open Association
8 N-SET (MPPS) - COMPLETED
9 Close Association
start exam,
acquire image
end exam
4 Open Association
5 N-SET (MPPS) - DISCONTINUED
6 Close Associationcancel exam
 
Figure 6 
SEQUENCING OF ACTIVITY – ACQUIRE IMAGES 
A possible sequence of interactions between the Workflow  AE and a Departmental Scheduler (e.g....

Page 28

 
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A  Page 28 
Table 27 
PROPOSED PRESENTATION CONTEXTS FOR  REAL-WORLD ACTIVITY ACQUIRE IMAGES 
Presentation Context Table 
Abstract Syntax  Transfer Syntax  
 
Role   
Ext. 
Neg. 
Name  UID Name List  UID List 
Modality Performed 
Procedure Step 1.2.840.10008.3.1.
2.3.3 Implicit VR Little Endian 
Explicit VR Little Endian  1.2.840.10008.1.2 
1.2.840.10008.1.2.1 
SCU None 
 
4.2.2.3.2.3  SOP Specific Conformance for MPPS 
Table 28 summarizes...

Page 29

 
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A  Page 29 
Table 29 
MPPS COMMUNICATION FAILURE BEHAVIOR 
Exception Behavior 
Timeout  Same as “Failure” above. 
Association aborted by the SCP or network layersSame as “Failure” above. 
 
Table 30 provides a description of the MPPS N-CREATE and N-SET request identifiers.  Empty cells in the N-
CREATE and N-SET columns indicate that the attribute is not sent.   
Table 30 
MPPS N-CREATE / N-SET REQUEST IDENTIFIER 
Attribute Name  Tag VR...

Page 30

 
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A  Page 30 
Attribute Name Tag  VRN-CREATE  N-SET 
(0032,1064) from MWL 
No value sent for unscheduled 
study.  unscheduled study. 
>Code Value 
(0008,0100)SHAs received from MWL  
No value sent for unscheduled 
study.  As received from MWL 
No value sent for 
unscheduled study.  
>Coding Scheme Designator 
(0008,0102)SHAs received from MWL  
No value sent for unscheduled 
study.  As received from MWL 
No value sent for 
unscheduled study....