Philips Hd 7 User Manual
Here you can view all the pages of manual Philips Hd 7 User Manual. The Philips manuals for Ultrasound System are available online for free. You can easily download all the documents as PDF.
Page 31
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 31 Attribute Name Tag VRN-CREATE N-SET Scheduled Step Attributes Sequence (0040,0270) SQ > Accession Number (0008,0050)SHFrom MWL or user PDE input. MWL value may be edited. > Referenced Study Sequence (0008,1110)SQOne item per item in the MWL Reference Study Sequence. Absent if unscheduled. >> Referenced SOP Class UID (0008,1150)UI Same value as in of the Reference Study Sequence in the MWL >> Referenced...
Page 32
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 32 4.2.2.4 Association Acceptance Policy The Workflow Application Entity does not accept Associations. 4.2.3 Hardcopy Application Entity Specification 4.2.3.1 SOP Classes HD7/HD7XE 3.0 provides Standard Conforma nce to the following SOP Classes: Table 31 SOP CLASSES FOR AE HARDCOPY SOP Class Name SOP Class UID SCU SCP Basic Grayscale Print Management Me ta 1.2.840.10008.5.1.1.9 Yes No Basic Color Print Management Meta...
Page 33
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 33 4.2.3.2.4 Implementation Identifying Information The implementation information for this Application Entity is: Table 35 DICOM IMPLEMENTATION CLASS AND VERSION FOR AE HARDCOPY Implementation Class UID 1.3.46.670589.14.3000.300 Implementation Version Name HD7_300 4.2.3.3 Association Initiation Policy 4.2.3.3.1 Activity – Film Images 4.2.3.3.1.1 Description and Sequencing of Activities The system composes images onto...
Page 34
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 34 Status of the print-job is reported through the Job Manager (CNTL-J). Only one job will be active at a time for each separate hardcopy device. If any Response from the remo te Application contains a status other than Success or Warning, the Association is aborted and t he related Job is switched to a failed state. It can be restarted any time by user interaction. 4.2.3.3.1.2 Proposed Presentation Contexts Table 36 shows...
Page 35
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 35 2. If Printer status (2110,0010) is FAILURE, the print-job is marked as failed. 3. If Printer status (2110,0010) is WARNING, the print-job continues to be printed. Table 39 summarizes the behavior of Hardcopy AE when encountering status codes in a N-GET response. Table 39 PRINTER SOP CLASS N-GET RESPON SE STATUS HANDLING BEHAVIOR Service Status Further Meaning Error Code Behavior Success Success 0000 The...
Page 36
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 36 Table 42 FILM SESSION SOP CLASS N-CREATE REQUEST ATTRIBUTES Attribute Name Tag VR Value Presence of Value Source Number of Copies (2000,0010) IS Default 1. Range is 1 – 99. ALWAYS USER Print Priority (2000,0020) CS HIGH ALWAYS AUTO Medium Type (2000,0030) CS BLUE FILM, CLEAR FILM or PAPER and ‘Printer Specific’ options* ALWAYS USER Film Destination (2000,0040) CS MAGAZINE or PROCESSOR and ‘Printer...
Page 37
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 37 Attribute Name Tag VR Value Presence of Value Source >Referenced SOP Class UID (0008,1150) UI 1.2.840.10008.5.1.1.1 ALWAYS AUTO >Referenced SOP Instance UID (0008,1155) UI From created Film Session SOP Instance ALWAYS AUTO Film Orientation (2010,0040) CS PORTRAIT or LANDSCAPE ALWAYS USER Film Size ID (2010,0050) CS Default – 8INX10IN and DICOM Defined Terms: 8INX10IN, 8_5INX11IN, 10INX12IN, 10INX14IN,...
Page 38
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 38 4.2.3.3.1.7.2 Film Box SOP Class Operations (N-ACTION) The Hardcopy AE issues an N-ACTION Re quest to instruct the Print SCP to print the contents of the Film Box. Table 49 summarizes the behavior of Hardcopy AE when en countering status codes in an N-ACTION response. Table 49 FILM BOX SOP CLASS N-ACTION RESPONSE STATUS HANDLING BEHAVIOR Service Status Further Meaning Error Code Behavior Success Success 0000 The SCP...
Page 39
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 39 >Columns (0028,0011) US Depends on film size, number of columns for entire sheet of film “Default is 2397” ALWAYS See Printer Catalog >Bits Allocated (0028,0100) US 8 ALWAYS AUTO >Bits Stored (0028,0101) US 8 ALWAYS AUTO >High Bit (0028,0102) US 7 ALWAYS AUTO >Pixel Representation (0028,0103) US 0 ALWAYS AUTO >Pixel Data (7FE0,0010) OW Pixels of rendered film sheet. ALWAYS AUTO * Mutually exclusive...
Page 40
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 40 Table 51.31 NUMBER OF ASSOCIATIONS INITIATED FOR AE VERIFICATION Maximum number of simultaneous Associations Up to 10, one for each configured remote device Table 51.32 NUMBER OF ASSOCIATIONS ACCEPTED FOR AE VERIFICATION Maximum number of simultaneous Associations Unlimited, however, calling AE must be already configured in HD7/HD7XE 3.0. 51.2.4.2.4 Asynchronous Nature HD7/HD7XE 3.0 do not support asynchronous...