Philips Hd 7 User Manual
Here you can view all the pages of manual Philips Hd 7 User Manual. The Philips manuals for Ultrasound System are available online for free. You can easily download all the documents as PDF.
Page 1
DICOM Conformance Statement HD7/HD7XE 3.0 000245000000008 Rev A 2010-09-30 © Koninklijke Philips Electronics N.V. 2010 All rights are reserved.
Page 2
0.1 REVISION HISTORY Document Version Date of Issue Author Description A Sept. 30, 2010 M. Leif Initial Release HD7/HD7XE 3.0 DICOM Conformance St atement 000245000000008 Rev. A Page 2
Page 3
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 3 1 CONFORMANCE STATEMENT OVERVIEW The Philips HD7/HD7XE 3.0 Ultrasound sy stems implement the necessary DICOM® services to download worklists from an information system, save acquired US Images and Structured Reports to a network storage device, CD or DVD, print to a networked hardcopy devic e and inform the information system about the work actually done. Table 1 provides an overview of the supported network services....
Page 4
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 4 STD-GEN-CDR for Structured Reports Yes / Yes No DVD STD-US-SC-MF(1)-DVD for Ultrasound images, compressed and uncompressed Yes / Yes Yes STD-GEN-DVD for Structured Reports Yes / Yes No (1) Note that the “MF” designator includes both Single Frame (SF) and Mullti-frame (MF) ultrasound images. Table 3 Supported STRUCTURED REPORT Templates Concept Name OB-GYN Ultrasound Procedure Report (Template ID 5000)...
Page 5
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 5 2 TABLE OF CONTENTS 0.1 REVISION HISTORY .......................................................................\ ....................................... . 2 1 CONFORMANCE STATEMENT OVERVIEW ........................................................................\ ................. 3 2 TABLE OF CONTENTS .......................................................................\ .........................................
Page 6
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 6 8.2 USED FIELDS IN RECEIVED IOD BY APPLICATION ......................................................... 62 8.3 ATTRIBUTE MAPPING .................................................................\ ........................................ 62 8.4 COERCED/MODIFI ED FIELDS........................................................................\ ..................... 63 8.5 CONTROLLED TERM INOLOGY...
Page 7
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 7 3 INTRODUCTION 3.1 AUDIENCE This document is intended for hospital staff, health care system integrators, software designers or implementers. It is assumed that the reader has a working understanding of DICOM. 3.2 REMARKS DICOM, by itself, does not guarantee inte roperability. However, the Conformance Statement facilitates a first-level validation for interoperability between different applications supporting the same DICOM...
Page 8
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 8 delivery. The user should ensure that any non-Philips pr ovider linking to Philips equipment also adapts to future versions of the DICOM Standard. If not, the incorporati on of DICOM enhancements into Philips equipment may lead to loss of connectivity (in case of networki ng) and incompatibility (in case of media). 3.3 DEFINITIONS, TERMS AND ABBREVIATIONS Definitions, terms and abbreviations used in this docu ment are...
Page 9
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 9 4 NETWORKING 4.1 IMPLEMENTATION MODEL 4.1.1 Application Data Flow Send Images, Reports, CommitsStorage A p plicatio n E ntity Remote A p plication E ntity R eceives Im ages, R eports, Com m its; R eturns C om m itm ents Update W o rklist Acquire Im ages Remote A p plication Entity Provides W orklistItem s Remote A p plication E ntity R eceives M P PS C reate / S et Workflow A p plicatio n E ntity Film Im ages Remote A p...
Page 10
HD7/HD7XE 3.0 DICOM Conformance Statement 000245000000008 Rev. A Page 10 job remaining in the queue (viewed using CNTL-J) signali ng the Auto-delete function that the exam qualifies for deletion. — The Workflow Application Entity receives Worklist information from and sends MPPS information to a remote AE. It is associated with the local real-world activiti es “Refresh Worklist” or automatic polling and “Acquire” images. When either the “Refresh Wo rklist” or automatic polling are...