6. INSTALLATION OF KEY SERVICE UNIT 6.1 PAD ADJUSTMENT AND EXPLANATION ON FUSES f \/ NOTE: PLEASE TURN OFF POWER SWITCH WITH. J OUT FAIL, BEFORE OPEN THE FRONT COVER 1.1 HOW TO DETACH FRONT COVER 1 Push up the slide. 2 Open the cover and detach it from the main body. CAUTION: TO AVOID ELECTRIC SHOCKS, NEVER OPEN THE INNER COVER. Set to “OFF” position 9 NOTE l Please use rated fuses only. l When replaceing fuse F5 and F6, detach by squeezing in the upper and lower surfaces of the plastic...
Page 12
. 6.2 CLAMPING OF INSTALLATION WIRING CABLES, AND INSTALLATION BATTERY UNIT (V~-20864). AND CONNECTION OF BACKUP 7 NOTE: PLEASE TURN OFF POWER SWITCH WITH- OUT FAIL, BEFORE INSTALLING THE BAT- TERY UNIT. J 1. CLAMPING OF INSTALLATION WIRING CABLES When performing the cable connections, pro- vide enough extra cable for the key service unit. This is necessary for future checks. Push in the cables from the top of the cable guide. / b f2. CONNECTION OF BACKUP BATTERY UNIT 3 1 Please turn off...
Page 13
7. INSTALLATION OF KEY TELEPHONE . 7.1 VOLUME ADJUSTMENT Incoming Ringing Tone Adjusting Volume I MAX’ m-1 I+MlN I ADJUSTMENT OF SPKR VOLUME SPKR Volume Adjusting Volume m MAX- [1111111-l I+MfN 7.2 HOW TO MOUNT THE KEY TELEPHONE ON THE WALL When modular jack for a wail phone is installed on the wall, the key telephone can be mounted and used on the wail. volume level is increased by approximately 6 dB. 1 RE-INSERTION OF HANDSET GUIDE 1 Pull out the handset 2 Reverse the direction of...
Page 14
6.3 HOW TO MOUNT THE KEY SERVICE UNIT ON THE WALL (USE THE KEY SERVICE UNIT ONLY ON THE WALL,) (1) Detach the case cover of the key service unit. Refer to 6.1.1. (2) Drill the wall according to the specified dimensions and install wood screws (0.16 in. in diameter) to the two places at the top. Leave each of the screw hea& sticking out 6.6 in. or SO (3) 1 Insert the mounting screw heads into the two upper 2 Pull down the rear case. mounting holes on the case. 3 The screw heads will be...
Page 15
3 INSTALLATION ON THE WALL 1 Connect the output cord from within the modular jack for a wall phone to the key service unit. 2 Using a short cord, connect the modular jack for a wall phone to the key telephone connector. 3 Mate the lower case hole to projection of modular jack for a wall phone.
Page 16
8. WIRING CONNECTION OF EQUIPMENTS 8.1 CONNECTION OF KEY SERVICE UNIT AND KEY TELEPHONE fyG--) When usmg five key telephones or more, use Exten- I sion EC unit. (See page 18) II TEL CONNECTION TERMINAL Make connections to TELs 1 through 4. - I 11 )IIIIIIl!llII) 1 ( 31 COLl ANDCOL2 II II/ Connect the Central Office Line (COL) to modular jack connector of COLl and COL2, respectively. l For couolino of cable. either of followina A. B and C can be used. and doorphone unit is connected. bell is...
Page 17
l CONNECTION EXAMPLE . EXPLANATORY NOTES cl A MODULAR MODULAR CONNECTOR -CONNECTOR TERMINAL BOX MODULAR CONNECTOR - BCREW :h,.“i%~~A~%,BBrj too) MODULAR . MODULAR CONNECTOR CONNECTOR MODULAR TERMINAL BOX 25 FEET CONNECTOR 200 FEET EY SERVICE UN11 TEL 5.6 KEY TEL TEL 7.8 S.L. TEL In case of using extension EC unit (VA-2084 1 I -2 25 FEET OR LESS 200 FEET OR LESS When VA-20841 is in usa, Single Line Tel is connectable. TEL 6 (Central office line) 200 FEET OR M( I 22 AWG I 24 AWG I...
Page 18
P F)at cable I FEET OR MORE ness of Quad Cable I Length of Quad Cable I 22 AWG I Within 1100 Feet 24AWG 26 AWG , Within 700 Feet Within 450 Feet 1 CONNECTION OF WIRING CABLE (FOR USE OF MODULAR CONNECTOR) l When the key service unit and TEL are within 25 feet, use a privately used cable, 7 feet, 15 feet and 25 feet cable are ready for use. l Telephone line cord and Handset cord Depending on connection method and length, 4 types of Telephone line cord and 2 types of Handset cord are...
Page 19
HOW TO USE CONNECTION TOOL 1 Cut a flat cable for a required length. 2 Peelcable sheath the modular clipping tool, and pull and remove the peeled cable sheath. At this time, leave the colored sheath of the conductor as it is. 3 Put the modular terminal to the flat cable. +e 4 Press and connect the terminal with B portion of the modular clipping tool. 2 *For the modular terminal at the opposite side, install the terminal in a reverse direction as shown in the illustration. RED BLACK YELLOW...
Page 20
8.2 INSTALLATION AND CONNECTION OF EXTENSION EC UNIT When using five key telephones or more, connect them using Extension EC Unit. The following types of Extension EC Units are available. A For extending 4 key telephones VA-20040 B For extending 2 key telephones and 2 SLTs VA-20841 (to be released shortly) B _ 7 NOTE: PLEASE TURN OFF POWER SWITCH WITHOUT FAIL, BEFORE INSTALLING THE EC UNIT J . 1 A. HOW TO INSTALL EC UNIT VA-20840 1. Put lower side of the EC unit to the rib. 2 Push down the...