71 UF-7000/8000 NOV 2004 Ve r. 2 . 0 UF-7100/8100 4.2. Service Modes (For Facsimile) Caution: The factory default parameters are preset (country dependent) for optimum performance and in compliance with the local telecommunication regulations/standards, and do not need to be changed. Changing some of these parameters may cause the unit to be no longer compliant or become inoperable. 4.2.1. Fax Service Mode Procedure 1. To enter the Fax Service Mode a. Press “FUNCTION” and then “7” keys. b. Press...
Page 72
72 UF-7000/8000 NOV 2004 Ve r. 2 . 0 UF-7100/8100 4.2.3. Fax Service Mode 1 (Function Parameter Setting) Use the following procedure to change the function parameters. Enter the desired code number and press “START” key. ↓ If you wish to select another code number, scroll the menu with the “V”, ”/\” arrow keys. ↓ Select the desired function code and press the START key. ↓ When the “CLEAR” key is pressed, the selected code input will not be accepted. ↓ Press “STOP” key, then press “FUNCTION” and “CLEAR”...
Page 73
73 UF-7000/8000 NOV 2004 Ve r. 2 . 0 UF-7100/8100 005Destination Code (UF-7100/8100 only)000 : Austria 001 : U.K. 002 : Canada 003 : Denmark 004 : Taiwan 005 : Finland 006 : Germany 007 : Netherlands 008 : Italy 009 : Spanish 010 : Hong Kong 011 : Australia 012 : Switzerland 013 : Norway 015 : Portuguese 016 : Ireland 017 : Belgium 018 : Sweden 019 : Turkey 020 : U.S.A. 021 : France 022 : New Zealand 025 : Japan 029 : Poland 030 : Czech 031 : Russia 032 : Greece 033 : Hungary 034 : Indonesia 035 :...
Page 74
74 UF-7000/8000 NOV 2004 Ve r. 2 . 0 UF-7100/8100 011 RX Level 1 = -43 dBm 2 = -38 dBm 3 = -33 dBm 4 = -48 dBmSelects the receiving sensitivity of -33/-38/-43/-48 dBm. 012 DTMF Level 00 = 0 dBm ~ 15 = -15 dBmSelects the DTMF output level, 0 to -15 dBm in 1 dBm steps. 013 G3 RX EQL 1 = 0dB 2 = 4dB 3 = 8dB 4 = 12dBSelects the cable equalizer for G3 reception mode, 0dB, 4dB, 8dB or 12dB. 014 G3 TX EQL 1 = 0dB 2 = 4dB 3 = 8dB 4 = 12dBSelects the cable equalizer for G3 transmission mode, 0dB, 4dB, 8dB or...
Page 75
75 UF-7000/8000 NOV 2004 Ve r. 2 . 0 UF-7100/8100 025 COMM. Start-Up 1 = First 2 = SecondSelects the communication start-up condition (XMT and Polling). (Used when Echo Suppression is disabled.) 026 Non-Standard 1 = Off (Invalid) 2 = On (Valid)Selects own mode (Panafax mode). 027 Short Protocol B 1 = Off (Invalid) 2 = On (Valid)Selects the short protocol mode. 028 Short Protocol D 1 = Off (Invalid) 2 = On (Valid)Selects the short protocol mode. When activated, it allows the machine to automatically...
Page 76
76 UF-7000/8000 NOV 2004 Ve r. 2 . 0 UF-7100/8100 044 Redial Count 0 = no redial ~ 15 = 15 times 0 ~ 9 (For Australia Only)Selects the redial count from 0 to 15 times in 1 step intervals. Note: In order to comply with the TBR21 requirement for the EC destinations, do not select 15 times. 045 Ring Detect Count1 = 1 ring ~ 9 = 9 ringsSelects the ring detection count from 1 to 9 rings in 1 ring step intervals. 046 On-Hook Time 0 = 0 sec. ~ 90 = 90 sec.Selects the on-hook time between sequential...
Page 77
77 UF-7000/8000 NOV 2004 Ve r. 2 . 0 UF-7100/8100 068 NYSE Fax Forward (USA and Canada Only)1 = Off 2 = OnSelects whether the machine will forward the incoming and outgoing faxes to a specified station. Note: Once this parameter is activated, Fax Forwarding via Fax Parameter 054 is automatically disabled, an Access Code of 0000 is automatically assigned and Fax Parameter 038 has a new setting added called NYSE. 069 NYSE Local Print (USA and Canada Only)1 = Inc 2 = On (Always)Selects the...
Page 78
78 UF-7000/8000 NOV 2004 Ve r. 2 . 0 UF-7100/8100 082 JAM Length 1 = 1 m 2 = 2 mSelects the maximum length of the original that can be scanned. 083 Not Used 084 Line As No Paper 1 = Ring (ring) 2 = Busy (keep line busy)Selects whether to ring or send a busy tone to the remote station when the recording paper runs out or the unit cannot receive because of any trouble. 085~ 086Not Used 087 Darker Level 0 = Lightest Contrast ~ 15 = Darkest ContrastSelects the contrast level. 0← →15 Lightest←...
Page 79
79 UF-7000/8000 NOV 2004 Ve r. 2 . 0 UF-7100/8100 Note 1: Continuous Polling (Station Mode) This feature allows you to Store or Add documents into a Polled file in memory. To enable the Continuous Polling feature set the Function Parameter No. 003 to 2:STN (Station). Depending on the setting of the User Parameter (Facsimile) No. 119: QWERTY KEYBOAD, one of the following operations is available:. 1. One-Touch The upper 40 (40↑) Key is reserved for Store 4 Polling function, and cannot be changed. To...
Page 80
80 UF-7000/8000 NOV 2004 Ve r. 2 . 0 UF-7100/8100 Note 4: The default setting of parameters depends on the country’s specifications or regulations. Print the Function Parameter List to confirm the default settings. Note 5: 200 Series Function Parameters Only appear when the G3 Communications Port Kit is installed and follow the same numbering order. Downloaded From ManualsPrinter.com Manuals