Page 131
DBS FF-1 System mode SECTION 400 (Version 3.0) Issue 1 January 1990 FFl-2#-4#-4#-(0 or l)# EP! control when paging - #02 It is set whether the EPI (External Page Interface) is to be used when calling paging group %02. O#: No EPI relav operation when callino paqinq arouo 02 l#: EPI relay operation when calling paging group 02 FFl-2#-4#-f#-(O or l)# EPI control when paging - #03 It is set whether the EPI (External Page Interface) is to be used when calling paging group #03. O#: No EPI relav...
Page 132
SECTION 400 (Version 3.0) Issue 1 January 1990 DBS FF-I System .mode FFl-3#-1 S-(0000 - 2359)# Automatic switching time for nighttime call mode The time for switching from daytime call mode to nighttime call mode is set so that the system does it automatically without the attendant performing the operation. It is specified using the 24 hour system. For example, when the system is to switch to the nighttime mode at 8:02pm, 2002 is input (00:OOam - 0000 / 11:59pm - 2359) JCONFIW: No automatic...
Page 133
SECTION 400 (Version 3.0) Issue 1 January 1990 ms FF-1 System mode Ff-?-3#-5#- (1 - 12)# Extension Transfer recall timer This specifiesif an outside line is transferred to another extension and is left unanswered for the length equal to or greater then this timer the call will recall to the original extension which established the transfer. O#:No recall 1 #:Recall after 20 seconds 2#:Recall after 40 seconds 3B:Recall after 60 seconds 4#:Recall after 80 seconds S#:Recall after 100 seconds...
Page 134
SECTION 400 (Version 3.0) DBS Issue 1 January 1990 FF-1 System mode FFl-3#-9#- (I- 12)# Extension park hold recall timer If an extension place a call in their park orbits, and leaves the call there for longer than the specified time, the call will recall to the extension. O#:No recall 1 #:Recall after 20 seconds 2#:Recall after 40 seconds 3B:Recall after 60 seconds 4#:Recall after 80 seconds S#:Recall after 100 seconds 68:Recall after 120 seconds 7#: Recall after 140 seconds 8#: Recall...
Page 135
DBS FF-1 System mode FFl-3#-12#-(1- lS)# Auto pause timer ’ When PBX lines and WATT lines are accommodated as outside lines of the system and connected to the telephone central office, it is necessary to have a pause in the dialing until the dialing signal from the DBS is received and until the dial tone is sent out from the connected CO. line. If this is neglected, the wrong party may be contacted or the connection may not be made. This pause time can be automatically set while when...
Page 136
SECTION 400 (Version 3.0) Issue 1 January 1990 DBS FF-1 System mode FFI-3#-15+(0-3)# Outside incoming ring signal detection timer The auto answer function for incoming calls is set to function normally. The continuous time forthe incoming call signal can be set within the range of 4 - 10 seconds. Even if the telephone has already been cut off by the party making it and the incoming call signal from the telephone line is discontinued, the system still treats it as an incoming call during the...
Page 137
DBS FF-1 System mode SECTION 400 (Version 3.0) Issue 1 January 1990 FFl-3#-17#-(O- 15)# Dial pause timer for after obtaining outside line The time to when sending out the number dialed starts after a connection with an outside line has been made is set For example. even if you start dialing immediately after pressing the line key, the dial signal is sent out to the outside line only after the specified time has elapsed. This setting is for when there is a risk of the dialing tone from the...
Page 138
: FFl-3#-19C(O- 15)# Call forward No answer timer If a call is not answered by an extension which has call foward no answer set within the specified ti’me period, the call will be diverted to a predetermined extension. The call forward no answer timer can be set from 4io 64 seconds. . O#:Call forward after 4 Seconds 1 #Xall forward after 8 Seconds _ Z#:Call forward after 12 Seconds 3$Kall forward after 16 Seconds 4#:Cail forward after 20 Seconds S#:Call fomard after 24 Seconds 6#:cBll...
Page 139
DBS FF-1 System mode SECTION 400 (Version 3.0) Issue 1 January 1990 3 - I - 5 DISA ID Code mode FFl-5#-(0000 - 9999)# DISA ID code storing (Direct inward System Access) Use of the DISA function allows for DID (Direct in dialing) from outside’the system and DISA outgoing call (making a call on a different line via the system from outside). If *is ID code is not set then system accept the DISA call withoutthe input ID cod, It also enables remote maintenance through a telephone circuit by the...
Page 140
SECTION 400 (Version 3-O) issue 1 January 1990 3 - 2 Trunk mode [Outside line port specificationl FFZ-(l -32)#-l#-(O or l)# i -Sl Trunk prohibition This is set for when an outside line port connected to the system has been damaged or for when it is desired to stop functioning to.specificoutside lines for some reason. -- O#: Operate (Default) 1 #c: Stop Operation FF2-(l- 32)#- 2#-(0 or l)# Dialing signal type set for outside line Dialing is done by pressing the 10 keys. But it is also...