Page 131

DBS 
FF-1 System mode SECTION 400 (Version 3.0) 
Issue 1 January 1990 
FFl-2#-4#-4#-(0 or l)# 
EP! control when paging - #02 
It is set whether the EPI (External Page Interface) is 
to be used when calling paging group %02. 
O#: No EPI relav operation when callino paqinq 
arouo 02 
l#: EPI relay operation when calling paging 
group 02 
FFl-2#-4#-f#-(O or l)# 
EPI control when paging - #03 
It is set whether the EPI (External Page Interface) is 
to be used when calling paging group #03. 
O#: No EPI relav...

Page 132

SECTION 400 (Version 3.0) 
Issue 1 January 1990 DBS 
FF-I System .mode 
FFl-3#-1 S-(0000 - 2359)# 
Automatic switching time for nighttime 
call mode 
The time for switching from daytime call mode to 
nighttime call mode is set so that the system does 
it automatically without the attendant 
performing the operation. 
It is specified using the 24 hour system. For 
example, when the system is to switch to the 
nighttime mode at 8:02pm, 2002 is input 
(00:OOam - 0000 / 11:59pm - 2359) 
JCONFIW: No automatic...

Page 133

SECTION 400 (Version 3.0) 
Issue 1 January 1990 ms 
FF-1 System mode 
Ff-?-3#-5#- (1 - 12)# 
Extension Transfer recall timer 
This specifiesif an outside line is transferred to 
another extension and is left unanswered for the 
length equal to or greater then this timer the call 
will recall to the original extension which 
established the transfer. 
O#:No recall 
1 #:Recall after 20 seconds 
2#:Recall after 40 seconds 
3B:Recall after 60 seconds 
4#:Recall after 80 seconds 
S#:Recall after 100 seconds...

Page 134

SECTION 400 (Version 3.0) DBS 
Issue 1 January 1990 FF-1 System mode 
FFl-3#-9#- (I- 12)# 
Extension park hold recall timer 
If an extension place a call in their park orbits, and 
leaves the call there for longer than the specified 
time, the call will recall to the extension. 
O#:No recall 
1 #:Recall after 20 seconds 
2#:Recall after 40 seconds 
3B:Recall after 60 seconds 
4#:Recall after 80 seconds 
S#:Recall after 100 seconds 
68:Recall after 120 seconds 
7#: Recall after 140 seconds 
8#: Recall...

Page 135

DBS 
FF-1 System mode 
FFl-3#-12#-(1- lS)# 
Auto pause timer ’ 
When PBX lines and WATT lines are 
accommodated as outside lines of the system and 
connected to the telephone central office, it is 
necessary to have a pause in the dialing until the 
dialing signal from the DBS is received and until 
the dial tone is sent out from the connected CO. 
line. If this is neglected, the wrong party may be 
contacted or the connection may not be made. 
This pause time can be automatically set while 
when...

Page 136

SECTION 400 (Version 3.0) 
Issue 1 January 1990 DBS 
FF-1 System mode 
FFI-3#-15+(0-3)# 
Outside incoming ring signal detection 
timer 
The auto answer function for incoming calls is set 
to function normally. The continuous time forthe 
incoming call signal can be set within the range of 
4 - 10 seconds. Even if the telephone has already 
been cut off by the party making it and the 
incoming call signal from the telephone line is 
discontinued, the system still treats it as an 
incoming call during the...

Page 137

DBS 
FF-1 System mode SECTION 400 (Version 3.0) 
Issue 1 January 1990 
FFl-3#-17#-(O- 15)# 
Dial pause timer for after obtaining 
outside line 
The time to when sending out the number dialed 
starts after a connection with an outside line has 
been made is set 
For example. even if you start dialing immediately 
after pressing the line key, the dial signal is sent 
out to the outside line only after the specified time 
has elapsed. 
This setting is for when there is a risk of the dialing 
tone from the...

Page 138

: 
FFl-3#-19C(O- 15)# 
Call forward No answer timer 
If a call is not answered by an extension which has 
call foward no answer set within the specified 
ti’me period, the call will be diverted to a 
predetermined extension. The call forward no 
answer timer can be set from 4io 64 seconds. . 
O#:Call forward after 4 Seconds 
1 #Xall forward after 8 Seconds 
_ Z#:Call forward after 12 Seconds 
3$Kall forward after 16 Seconds 
4#:Cail forward after 20 Seconds 
S#:Call fomard after 24 Seconds 
6#:cBll...

Page 139

DBS 
FF-1 System mode SECTION 400 (Version 3.0) 
Issue 1 January 1990 
3 - I - 5 DISA ID Code mode 
FFl-5#-(0000 - 9999)# 
DISA ID code storing 
(Direct inward System Access) 
Use of the DISA function allows for DID (Direct in 
dialing) from outside’the system and DISA 
outgoing call (making a call on a different line via 
the system from outside). 
If *is ID code is not set then system accept the 
DISA call withoutthe input ID cod, It also enables 
remote maintenance through a telephone circuit 
by the...

Page 140

SECTION 400 (Version 3-O) 
issue 1 January 1990 
3 - 2 Trunk mode 
[Outside line port specificationl 
FFZ-(l -32)#-l#-(O or l)# i -Sl 
Trunk prohibition 
This is set for when an outside line port connected 
to the system has been damaged or for when it is 
desired to stop functioning to.specificoutside 
lines for some reason. 
-- 
O#: Operate (Default) 
1 #c: Stop Operation 
FF2-(l- 32)#- 2#-(0 or l)# 
Dialing signal type set for outside line 
Dialing is done by pressing the 10 keys. But it is 
also...