Returning the unit to the factory default state (INITIALIZE)
You can restore the settings stored on the unit to the factory defaults 
(INITIALIZE)
When executing INITIALIZE, select one of “ALL” or “SETUP” .
ALL :Restores all settings to the factory default state (executes 
INITIALIZE)

 .
SETUP :Restores only some settings to the factory default state 
(executes INITIALIZE)

 .
zzFor details on initializing the settings stored on a remote camera, 
refer to the Operating Instructions for the remote...

Page 42

42
Returning the unit to the factory default 
state
1 . Press the MENU button .
2 . Open SYSTEM menu [49] .
3 . Turn the F1 dial to display the “1 .  INITIALIZE” item  .
1 . I N I T I A L I Z E
                        A L L
4 . Turn the F2 dial to select “ALL” or “SETUP”, and then 
press the F2 dial to confirm the selection
 .
INITIALIZE is executed .
ALL :Restores all settings to the factory default state (executes 
INITIALIZE)

 .
SETUP :Restores only some settings to the factory default state...

Page 43

43
Control interface for external devices
„„TALLY/GPI (JST: JBY‑25S‑1A3F(LF)(SN))
13
1
25 14Pin number Signal name
Description of signalOperation
1 TALLY
 

IN   1
TALLY
 

IN1 to TALLY
 
 IN10 tally inputs
⇒	 “Tally settings” (page
  39)Contact input
(Status operation)
14 TALLY
 

IN   2
2 TALLY
 

IN   3
15 TALLY
 

IN   4
3 TALLY
 

IN   5
16 TALLY
 

IN   6
4 TALLY
 

IN   7
17 TALLY
 

IN   8
5 TALLY
 

IN   9
18 TALLY
 

IN   10
6 GND GND
19 GPI
  IN   1Calling of PMEM
  GROUP1 to PMEM...

Page 44

44
Registering camera numbers to CAM OUT1 to 
CAM   OUT10
1 . Press the MENU button .
2 . Open GPI OUT menu [45] .
3 . Turn the F1 dial to display the “1  .  CAM   OUT1” item  .
1 . C A M   O U T 1
                      C A M 1
4 . Turn the F2 dial to select the camera number to set for 
CAM OUT1, and then press the F2 dial to confirm the 
selection
 .
Camera number : Select from CAM1 to CAM100  .
5 . Turn the F1 dial to display any of the “2 . CAM OUT2” 
to “10  .  CAM   OUT10” items and then register a...

Page 45

45
Setup Software
Setup Software is an application for configuring the settings for connecting the unit with the remote cameras and switcher from a personal computer . 
The settings can be configured while confirming each item in a list  .
zzThe settings for connecting the unit with the remote cameras 

and switcher can also be configured using just the unit  .  For how to configure the settings 
on the unit, refer to “Settings for connecting with the remote cameras and switcher” in  (page
  29)  .
When...

Page 46

46
Setup Software (continued)
Connecting the personal computer
Connect the personal computer and unit with a LAN cable .
zzWhen directly connecting the personal computer to the unit, use a crossover cable (category 5 or better shielded cable)

 .
zzWhen connecting via a switching hub, use a straight cable (category 5 or better shielded cable)

 .
Personal computer
Personal computer
Switching hub LAN cable (straight cable)
LAN cable (crossover cable)
LAN cable (straight cable) 

Page 47

47
Setup Software (continued)
The screens of  Windows XP are used in the explanations in this manual  .
If you are using an operating system other than Windows XP

, some of the items displayed on the screens may differ
 .
Registering the unit in Setup Software
On the “IP Address” tab, register the IP addresses of units to be set from Setup Software .The units registered here can be selected from the list box on the “Setting” tab  .
Up to five units can be registered

 .
1 . Enter the IP addresses in the...

Page 48

48
Setup Software (continued)
Settings for connecting with the remote cameras and switcher
Displaying the “Setting” tab
On the “Setting” tab, configure the settings for the connections between the unit and the remote cameras and switcher .When you connect the personal computer to the unit for the first time, click the [REFRESH] button to acquire the values set on the unit .
Each of the “C001” to “C100” and “SW” lines displays a list of the corresponding camera number and switcher connection setting...

Page 49

49
Setup Software (continued)
141516171819
1213
12 RECEIVE PORT NO Set the port numbers for the unit to receive camera information 
update notifications from remote cameras
 .
Possible setting range: 61000 to 65535 zzSet 10 port numbers because update notifications are received 
from the remote cameras included in the selected camera group

 .
 
After entering the information on the “C001” to “C010” lines, click 
[SET] button to reflect the changes

 .
13 ALARM Displays the alarm information of the...

Page 50

50
Setup Software (continued)
Setting user authentication
To control remote cameras that have the user authentication function enabled, you need to set the user name and password on the AW‑RP120 .Configure this setting on the “User Auth  . ” tab of this application  .
zzThe user authentication function is only enabled when the unit is controlling remote cameras connected with IP  connections

 .  Also refer to the 
Operating Instructions for the remote cameras
 .
1 . Click the [REFRESH] button .The user...