41 Returning the unit to the factory default state (INITIALIZE) You can restore the settings stored on the unit to the factory defaults (INITIALIZE) When executing INITIALIZE, select one of “ALL” or “SETUP” . ALL :Restores all settings to the factory default state (executes INITIALIZE) . SETUP :Restores only some settings to the factory default state (executes INITIALIZE) . zzFor details on initializing the settings stored on a remote camera, refer to the Operating Instructions for the remote...
Page 42
42 Returning the unit to the factory default state 1 . Press the MENU button . 2 . Open SYSTEM menu [49] . 3 . Turn the F1 dial to display the “1 . INITIALIZE” item . 1 . I N I T I A L I Z E A L L 4 . Turn the F2 dial to select “ALL” or “SETUP”, and then press the F2 dial to confirm the selection . INITIALIZE is executed . ALL :Restores all settings to the factory default state (executes INITIALIZE) . SETUP :Restores only some settings to the factory default state...
Page 43
43 Control interface for external devices TALLY/GPI (JST: JBY‑25S‑1A3F(LF)(SN)) 13 1 25 14Pin number Signal name Description of signalOperation 1 TALLY IN 1 TALLY IN1 to TALLY IN10 tally inputs ⇒ “Tally settings” (page 39)Contact input (Status operation) 14 TALLY IN 2 2 TALLY IN 3 15 TALLY IN 4 3 TALLY IN 5 16 TALLY IN 6 4 TALLY IN 7 17 TALLY IN 8 5 TALLY IN 9 18 TALLY IN 10 6 GND GND 19 GPI IN 1Calling of PMEM GROUP1 to PMEM...
Page 44
44 Registering camera numbers to CAM OUT1 to CAM OUT10 1 . Press the MENU button . 2 . Open GPI OUT menu [45] . 3 . Turn the F1 dial to display the “1 . CAM OUT1” item . 1 . C A M O U T 1 C A M 1 4 . Turn the F2 dial to select the camera number to set for CAM OUT1, and then press the F2 dial to confirm the selection . Camera number : Select from CAM1 to CAM100 . 5 . Turn the F1 dial to display any of the “2 . CAM OUT2” to “10 . CAM OUT10” items and then register a...
Page 45
45 Setup Software Setup Software is an application for configuring the settings for connecting the unit with the remote cameras and switcher from a personal computer . The settings can be configured while confirming each item in a list . zzThe settings for connecting the unit with the remote cameras and switcher can also be configured using just the unit . For how to configure the settings on the unit, refer to “Settings for connecting with the remote cameras and switcher” in (page 29) . When...
Page 46
46 Setup Software (continued) Connecting the personal computer Connect the personal computer and unit with a LAN cable . zzWhen directly connecting the personal computer to the unit, use a crossover cable (category 5 or better shielded cable) . zzWhen connecting via a switching hub, use a straight cable (category 5 or better shielded cable) . Personal computer Personal computer Switching hub LAN cable (straight cable) LAN cable (crossover cable) LAN cable (straight cable)
Page 47
47 Setup Software (continued) The screens of Windows XP are used in the explanations in this manual . If you are using an operating system other than Windows XP , some of the items displayed on the screens may differ . Registering the unit in Setup Software On the “IP Address” tab, register the IP addresses of units to be set from Setup Software .The units registered here can be selected from the list box on the “Setting” tab . Up to five units can be registered . 1 . Enter the IP addresses in the...
Page 48
48 Setup Software (continued) Settings for connecting with the remote cameras and switcher Displaying the “Setting” tab On the “Setting” tab, configure the settings for the connections between the unit and the remote cameras and switcher .When you connect the personal computer to the unit for the first time, click the [REFRESH] button to acquire the values set on the unit . Each of the “C001” to “C100” and “SW” lines displays a list of the corresponding camera number and switcher connection setting...
Page 49
49 Setup Software (continued) 141516171819 1213 12 RECEIVE PORT NO Set the port numbers for the unit to receive camera information update notifications from remote cameras . Possible setting range: 61000 to 65535 zzSet 10 port numbers because update notifications are received from the remote cameras included in the selected camera group . After entering the information on the “C001” to “C010” lines, click [SET] button to reflect the changes . 13 ALARM Displays the alarm information of the...
Page 50
50 Setup Software (continued) Setting user authentication To control remote cameras that have the user authentication function enabled, you need to set the user name and password on the AW‑RP120 .Configure this setting on the “User Auth . ” tab of this application . zzThe user authentication function is only enabled when the unit is controlling remote cameras connected with IP connections . Also refer to the Operating Instructions for the remote cameras . 1 . Click the [REFRESH] button .The user...