Page 31
31 Setting linking with a switcher Configure the settings for linking the unit with an optional switcher .To use the function for linking with a switcher, you need to set the following in advance . Settings for the connection between unit and switcherRefer to “Settings for connecting with the remote cameras and switcher” in (page 29) . Settings on the switcherThe following settings can be configured on the AW‑HS50 .zz Enabling the function for linking with the unit Set the...
Page 32
32 Setting the functions for when the unit is linked with the switcher Set the functions that can be used when there is a link between the unit and switcher .Each of the functions needs to be set in advance in SW FUNCTION menu [42] and SW INPUT menu [43] . ⇒ “Registering the camera numbers that will correspond to the image inputs of the switcher” (page 31) ⇒ “Enabling or disabling the function for linking with the switcher” (page 31) BUSCONT function Select the bus material of the...
Page 33
33 FOCUS ASSIST function Control the AUX bus of the switcher and switch between the “images of multi view” and the “images of the selected remote camera” . Assigning this function to a USER button makes it optimal for adjusting the focus and other settings because you can fill the screen with the images of the selected remote camera with just the press of a button . Setting the FOCUS ASSIST function 1 . Press the MENU button . 2 . Open SW FUNCTION menu [42] . 3 . Turn the F1 dial to display the “4 ....
Page 34
34 TALLY IP function Enable TALLY IP to receive OA tally information from the switcher via the network . The lighting statuses of the camera status indicators on the unit and the tally lamps on the remote cameras are changed based on the received OA tally information . Enabling or disabling the TALLY IP function 1 . Press the MENU button . 2 . Open SW FUNCTION menu [42] . 3 . Turn the F1 dial to display the “6 . TALLY_IP” item . 6 . T A L L Y _ I P O f f 4 . Turn the F2...
Page 35
35 CAM INF function You can display the remote camera setting information acquired by the unit on the switcher AUX bus output images or multi view images . zzThe setting information for the remote cameras included in the selected camera group is displayed . zzThe setting information for a remote camera connected via a serial connection is displayed only when the camera is selected with a camera selection button [CAMERA SELECT/GROUP SELECT] . Enabling or disabling the CAM INF function 1 . Press...
Page 36
36 Memory card operations The unit allows you to use a memory card to perform the following operations . SA VE : Save the configuration data of the unit or a remote camera to a memory card . LOAD :Load the configuration data saved to a memory card to the unit or a remote camera . Data type Description of data File names *1SAVE/ LOAD RPDAT Configuration data of unit *2RP01 .s12 to RP99 . s12 SAVE and LOAD CAM Configuration data stored on the remote cameras *3RP01 .c12 to RP99 . c12...
Page 37
37 Initializing a memory card (INIT) Before using a memory card with the unit, be sure to initialize the memory card with the unit . When the memory card is initialized, the memory card is formatted (in compliance with SD standards) and dedicated directories are created . zzIf you initialize a memory card, all of the files stored in the memory card will be deleted . Be sure to execute initialization after confirming the data because any data that is deleted by the initialization cannot be...
Page 38
38 Loading data from a memory card (LOAD) 1 . Press one of the camera selection buttons [CAMERA SELECT/GROUP SELECT] to select a remote camera . 2 . Press the MENU button to turn on its indicator . 3 . Open SD LOAD menu [47] . L O A D M O D E : R P D A T 4 . Turn the F1 dial to select the type of data to load from the memory card, and then press the F1 dial to confirm the selection . The file saved to the memory card is displayed on the second line of the LCD panel . L O A D M O D E : R...
Page 39
39 Tally settings The unit can receive the tally information of the switcher and other external devices from the TALLY/GPI connector (TALLY input) on the rear panel and two network lines . T o enable turning on the camera status indicators on the unit and the tally lamps on the remote cameras based on the received tally information, you need to configure the following settings . Registering the camera numbers that will correspond to the TALLY inputs Setting is required to use TALLY IN1...
Page 40
40 Checking alarm information In the event of an error with the power supply of the unit or a remote camera included in the selected camera group, the ALARM indicator on the unit turns on and the output of the GPI OUT connector (GPI OUT 5) becomes On . When an error occurs, you can check the alarm information by menu operation . Displaying alarm information 1 . Press the MENU button . 2 . Open ALARM menu [50] . 3 . Turn the F1 dial to display the item you want to check .The alarm status is...