Select “Enable” to use the E- mail function. 91 E-mail setup page With this projector, if a problem occurs or if the lamp usage time reaches a set value, an e-mail message can be sent to one or more preset e-mail addresses (maximum two addresses). Click [Projector Control], then [E-mail set up] to display the E-mail setup page. Enter the IP address or server name of the E-mail server (SMTP). The DNS server must be set if the server name is entered. Enter the E-mail address of the projector. (maximum 63 characters) The user can modify the minimum time interval of temperature warning mail. The default value is 60 minutes. In this case, the user cannot send another mail for 60 minutes after sending previous temperature warning mail even the set warning temperature is reached again. The user can enter the location of, for example, the installed projector so that the recipient may easily identify the originator of the E-mail. (maximum 63 characters) The user can modify the threshold temperature for sending temperature warning mail. If the temperature rises above the set value, control sends temperature warning mail.Enter the E-mail address of your desired recipient. Select the conditions for sending E-mail. Error: an error is detected by self- diagnosis. Warning LAMP1:remaining lamp service time has reached the value set in the field. Warning LAMP2:remaining lamp service time has reached the value set in the field. Warning input air Temperature: intake air temperature has reached the value set in the field. Warning output air Temperature: exhaust temperature has reached the value set in the field. Periodic warning interval setting (e-mail is sent on the checked days of the week/times) (Continued on next page)
92 How to use network function (optional) Enter the E-mail address to which the E-mail is to be sent when two E-mail addresses are going to be used. Do not enter it when the second E- mail address is not going to be used. Select the conditions for sending E-mail. Error:an error is detected by self-diagnosis. Warning LAMP1:remaining lamp service time has reached the value set in the field. Warning LAMP2:remaining lamp service time has reached the value set in the field. Warning input air Temperature: intake air temperature has reached the value set in the field. Warning output air Temperature:exhaust temperature has reached the value set in the field. Check these boxes when E- mail is to be sent periodically to two E-mail addresses. E- mail will be sent at the times and on the days checked. Button to update settings DNS server set up page Click [Network set up], then [DNS server set up] to display the DNS server set up page. Button to update settings Primary DNS server address Available input characters: Numbers (0 - 9), period (.) (ex. 192.168.0.253) Secondary DNS server address Available input characters: Numbers (0 - 9), period (.) (ex. 192.168.0.254)
93 POP server setup page The POP server is set on this page when POP authentication is required for mail transmissions. Click [Network set up], then [POP server set up] to display the POP server setup page. Select “Enable” for this setting only when authentication is required for sending mail. POP server name field Available input characters: Alphanumeric characters (A–Z, a–z, 0–9), hyphen (-), period (.) POP server user name field Button to update settings POP server password field Ping test page This page makes it possible to check whether the network is connected to the E-mail server, POP server, DNS server, etc. Click [Network set up], then [Ping test] to display the Ping test page. Enter the IP address of the server to be tested. Button for conducting the test. Display which appears when the connection was successful. Display which appears when the connection failed.
94 Subject: Panasonic projector report(CONFIGURE) === Panasonic projector report(CONFIGURE) === Projector Type : D7700 –––––E-mail setup data ––––– TEMPERATURE WARNING SETUP MINIMUM TIME at [ 60] minutes interval INPUT AIR TEMPERATURE Over [ 35C / 95F ] ERROR [ ON ] LAMP1 RUNTIME [ OFF ] at REMAIN [200] H LAMP1 RUNTIME [ OFF ] at REMAIN [100] H LAMP2 RUNTIME [ OFF ] at REMAIN [200] H LAMP2 RUNTIME [ OFF ] at REMAIN [100] H INPUT AIR TEMPERATURE [ OFF ] PERIODIC REPORT Sunday [ OFF ] Monday [ OFF ] Tuesday [ OFF ] Wednesday [ ON ] Thursday [ OFF ] Friday [ OFF ] Saturday [ OFF ] 00:00 [ OFF ] 01:00 [ OFF ] 02:00 [ OFF ] 03:00 [ OFF ] 04:00 [ OFF ] 05:00 [ OFF ] 06:00 [ OFF ] 07:00 [ OFF ] 08:00 [ OFF ] 09:00 [ OFF ] 10:00 [ OFF ] 11:00 [ OFF ] 12:00 [ OFF ] 13:00 [ OFF ] 14:00 [ OFF ] 15:00 [ OFF ] 16:00 [ OFF ] 17:00 [ OFF ] 18:00 [ ON ] 19:00 [ OFF ] 20:00 [ OFF ] 21:00 [ OFF ] 22:00 [ OFF ] 23:00 [ OFF ] –––––check system ––––– MAIN CPU BUS [ OK ] FAN [ OK ] OPTICS MODULE TEMPERATURE [ OK ] INPUT AIR TEMPERATURE [ OK ] OUTPUT AIR TEMPERATURE [ OK ] LAMP2 REMAIN TIME [ OK ] LAMP1 REMAIN TIME [ OK ] • • • Contents of mail sent • Mail with the contents shown below is sent when the E-mail settings have been established. Subject: Panasonic projector report(ERROR) === Panasonic projector report(ERROR) === Projector Type : D7700 –––––check system ––––– MAIN CPU BUS [ OK ] FAN [ OK ] OPTICS MODULE TEMPERATURE [ OK ] INPUT AIR TEMPERATURE [ OK ] OUTPUT AIR TEMPERATURE [ OK ] LAMP2 REMAIN TIME [ OK ] LAMP1 REMAIN TIME [ OK ] LAMP2 STATUS [ OK ] LAMP1 STATUS [ FAILED ] OPTICS MODULE TEMP.SENSOR [ OK ] INPUT AIR TEMP.SENSOR [ OK ] OUTPUT AIR TEMP.SENSOR [ OK ] BATTERY [ OK ] (Error code 00 40 00 00) Input air temperature : 27 degC / 80 degF Output air temperature : 65 degC /149 degF SET RUNTIME 1857 H POWER ON 248 times LAMP1 ON 177 times LAMP1 LOW 0 H LAMP1 HIGH 68 H LAMP2 ON 183 times LAMP2 LOW 0 H LAMP2 HIGH 75 H LAMP1 REMAIN 1432 H LAMP2 REMAIN 1425 H –––––Network configuration ––––– IP address 192.168.0.8 MAC address 00:00:00:00:00:00 Wed Jan 26 18:54:31 2005 –––––Memo ––––– • Mail with the contents shown below is sent when an error has occurred. How to use network function (optional)
95 Adjust clock page Click [Network set up], then [Adjust clock] to display the Adjust clock page. Time zone selection Button to update time zone setting Button to update time and date settings New date field New time field Network config page Set this to ON to enable the DHCP client function. Enter the IP address if DHCP server is not used. Enter the net mask if DHCP server is not used. Enter the port number here. Number 80 is normally used. Enter the gateway address if DHCP server is not used. Enter the name of the projector here. Enter the host name here if it is required when the DHCP server is going to be used, for instance. • If the time becomes incorrect immediately after setting the correct time, then the battery needs to be changed. Contact the dealer where you bought the projector to have the battery changed. Note
96 Firmware update page (The firmware should be updated only by an individual with the specialized knowledge required to do this.) Enter here the filename of the firmware to be updated. After entering the filename, press the [Upload] button. Data transfer is now commenced. It will take several dozen seconds for the data to be transferred. The time taken will differ depending on the network conditions. Displays the current version. Displays the updated version. Check the updated version against the current version, and if everything is in order, press the [Write] button. Version data rewriting is now commenced. Do not turn off the power while the version data is being rewritten. • Messages such as the ones shown below appear during data rewriting. • The following message appears upon completion of the version data rewriting. How to use network function (optional)
97 Press the “ENTER” button. The OPTION screen will be displayed. Select “NETWORK SETTING” with the buttons. Returning the network function setting back to the factory setting Using the following procedure, the user can return all settings of network function such as IP address, password and Email setting to the factory setting. Procedure of setting Press the “MENU” button. The MAIN MENU screen will be displayed. Select “OPTION” with the buttons. Press the “ENTER” button. The NETWORK SETTING screen will be displayed. Select “STORE” with the buttons. Hold down the “Standard (STD)” button for 3 seconds. A confirmation screen will be displayed. To cancel, press the “MENU” button. The NETWORK SETTING screen will be displayed. Press the “ENTER” button. The IP address, password, E-mail settings and all the other network function settings are returned to the factory defaults. OPTION PROJECTOR ID 2 SETTING FRONT-F LAMP SELECT DUAL LAMP POWER HIGH RS232C SETTING OSD POSITION 2 SYSTEM INFORMATION COLOR MATCHING 3COLORS VIDEO SETTING NETWORK SETTING :MENU SELECT ENTER:SUB MENU MAIN MENU PICTURE POSITION ADVANCED MENU LANGUAGE OPTION TEST PATTERN SIGNAL LIST SECURITY :MENU SELECT ENTER:SUB MENU NETWORK SETTING HOST NAME PROJECTOR DHCP OFF IP ADDRESS 192.168. 0. 8 PORT 80 NET MASK 255.255.255. 0 GATEWAY 192.168. 0. 1 MAC ADDRESS 00.00.00.00.00.00 STORE :MENU SELECT ENTER:ADJUST WOULD YOU LIKE TO CANCEL ALL NETWORK SETTINGS BACK TO FACTORY SHIPMENT STATUS? OK ESC :CHANGEyENTER:SET
98 Indication of monitor lamp Three monitor lamps are provided at the top of main unit front to inform the user of the lamp replacement time and unusual internal temperature. These lamps indicate the degree of abnormality by combination of blinking and/or lighting lamps. Turn off the power and take the proper measure according to the table below. Lamp 2 monitor (LAMP2) Lamp 1 monitor (LAMP1) Temperature monitor (TEMP) TEMP LAMP1 LAMP2POWER • Be sure to observe the procedure (How to turn “ON” and “OFF” the power supply) on page 35–36 when performing power supply operation to take a measure to the indication of temperature monitor (TEMP) lamp and lamp monitor (LAMP) lamp.Attention Name of monitor lampLamp indicationInformation Warm-up status High temperature inside. (WARNING)• Check if the ventilation port is blocked. • Is the room air temperature too high? • Check the air filter for clogging. Checkpoint • Remove the object that is blocking the ventilation port. • Move the projector to a temperature of 0 to 40 ˚C and the humidity of 20 to 80% (no condensation). • Turn off the MAIN POWER switch using the procedure on page 36 and clean the air filter (refer to page 99). • Did you turn on the power when the ambient temperature was low (approx. 0 °C)? • Wait about five minutes in the current status. • Install the unit in a location having an ambient temperature from 0 to 40 °C. Lighting in red (lamp unit ON) Remedial measure Blinking in red (2 times)High temperature inside (Standby condition) Blinking in red (3 times)Cooling fan has been stopped. • Turn off the main power supply (MAIN POWER) switch in the procedure shown on page 36 and consult the distributor. • This lamp monitor lights up when the lamp unit used hours have reached 1 300 hours (3 800 hours when Long Life Lamp Units are used). Request the dealer to replace the lamp unit. • Turn off the MAIN POWER switch using the procedure on page 36 and consult the dealer. • Did you notice a “REPLACE THE LAMP” message on the screen when turning on the projector power supply? • Some error has arisen in the lamp circuit. • Check for fluctuation (or drop) in the source voltage. Indicates the time for replacing the lamp unit. Error is detected in the lamp circuit. Lighting in red Blinking in red (3 times) Temperature monitor TEMP Lamp monitor LAMP1 LAMP2 • Wait until the lamp has cooled off, and then turn on the power.• Did you turn the power back on immediately after turning it off?
99 Cleaning and replacement of air filter Turn off the main power and remove the power plug from the receptacle. Turn off the power supply observing the procedure (How to turn “OFF” the power supply) on page 36 and then remove the power plug. Dismantle the air filter. Put a hand in the bottom of the air filter, take out the filter from the main unit while pulling toward yourself. Clean the air filter. Suck off deposited dust with a vacuum cleaner. Mount the air filter. Set the air filter and then mount the filter in the reverse order to step . Air filter • Be careful not to suck in the air filter itself. • The air filter must be fitted in place when using the projector. Using the projector without the air filter fitted inside, dirt and dust are sucked into the projector, causing failure. Attention Attention • If cleaning cannot remove the dust completely, then it is a sign to replace the air filter. Consult the dealer. In addition, when the lamp unit is replaced, also replace the air filter. Note If too much dust is deposited in the air filter, temperature inside the main unit will rise and the temperature monitor (TEMP) lamp blinks, eventually turning off the power supply. Clean the air filter section once every 100 hours or so as a guideline depending on the location of projector operation. Procedure of cleaning
100 Replacement of lamp unit Precautions on lamp unit replacement Be careful when handling a light source lamp. The lamp unit has high internal pressure. If improperly handled, failure might result. A used lamp unit may burst if it is handled violently. For disposition of used lamps, request an industrial waste disposal contractor. Do not reset the cumulative time, except when the lamp unit has been replaced with a new unit. If you continue to use a lamp after the replacement time, the lamp may break. Philips screwdriver is necessary when replacing a lamp unit. Take care not to slip your hand when using a screwdriver. • A lamp unit is an optional part. Contact the dealer. Replacement Lamp Unit model No.: ET-LAD7700 (single bulb), ET-LAD7700W (double bulbs) Rating: 300W Long Life Lamp Unit model No.: ET-LAD7700L (single bulb), ET-LAD7700LW (double bulbs) Rating: 160W • Other lamps than specified above cannot be used. Be sure to use the specified lamp.AttentionThe lamp used for the light source has its due life. The life of light source lamp used in the main unit is 1 500 hours 1(when lamp output is HIGH and lamp selection is DUAL). However, it may happen that the lamp becomes dead (will not light) by the time of 1 500 hours 1depending on the characteristics of individual lamps and working conditions (lamps may reduce their life affected by the times of lighting and the intervals between previous lighting and next lighting). Therefore, it is strongly recommended for the user to keep a spare bulb. If your lamp unit is not replaced after 1 300 hours 2 (with the lamp output set at “HIGH”), power supply will be turned off automatically at the time of 1 500 hours1, entering a standby state. After 1 500 hours1of initial lighting, power supply is turned off automatically about 10 minutes later, entering a standby state even if it is turned on again. Indication after 1 300 hours2 (with the lamp output set at HIGH) When lamp unit used hours have reached 1 300 hours2, lamp monitor (LAMP1 or LAMP2) light up including standby state. Further, an on-screen indication will appear for about 30 seconds as shown in the diagram on the right, recommending replacement of lamp unit. (The indication on the below diagram will disappear after about 30 seconds or when either control button on the rear of main unit or remote control button is operated.) After the time of 1 500 hours 1, the on-screen indication will not disappear unless the menu (MENU) button is operated. REPLACE THE LAMP CAUTION Wait until the lamp is cooled sufficiently before replacing the lamp unit. Timing of lamp unit replacement 1 This time period is 4 000 hours when Long Life Lamp Units are used. 2 This time period is 3 800 hours when Long Life Lamp Units are used.