31 Register an encoder [Basic setup] Step 1 Click the [Device mng.] button. →The Registered device window will be displayed. Step 2 Click the [Encoder] tab. →The Registered device window of the encoder will be displayed. The following are descriptions about each item dis- played on the Registered device window of the encoder. Registered device Titles of the registered encoders, model numbers and theirs addresses will be displayed in list form. Number of device Number of the registered encoders will be displayed. [Add…] button The Device registration window will be displayed. [Edit…] button The Device registration window of the encoder selected from the list will be displayed. [Delete…] button The encoder selected from the list will be deleted. Step 3 Click the [Add…] button. →The Device registration window will be displayed. Note: The [Add…] button will become unavailable when reached the maximum number of encoder registra- tion. The following are descriptions about each item dis- played on the Device registration window of the encoder. Address Enter the IP address of the encoder. Enter up to 255 alphanumeric characters for the address. HTTP port number Enter a number from 1 to 65535 for the HTTP port number. Default:80 Use a proxy server Determine whether to use or not use a proxy server to connect the encoder. ON:Use a proxy server OFF:Not use a proxy server Default:OFF Important: When receiving MPEG-4 images, live images will be received without using a proxy server.
32 Note: The proxy server address can be set on the [Basic setup] tab of the Comm page (page 54). [Start…] button Encoder information will be downloaded based on the settings of Address, HTTP port number and Use a proxy server. Model no. The model number contained in the downloaded encoder information will be displayed. Unknown will be displayed when encoder information is not downloaded yet. Device title Enter the encoder title. Enter up to 16 characters. The following characters are unavailable for the encoder title. ! $ % ’ < = > @ [ ]^ _ ` { | } ~ [Setup…] button The Camera setup window will be displayed. The [Setup…] button will be unavailable until encoder information is downloaded. [Set] button The edited settings will be saved and applied. Step 4 Complete the settings of Address, HTTP port num- ber and Use a proxy server. Step 5 Click the [Start…] button. Important: When the settings of the setup menu of the encoder are edited, download the encoder informa- tion again. Note: When a message window is displayed by clicking the [Start…] button, refer to the Displayed mes- sages and solutions section on page 73 and follow the instructions. Step 6 Click the [OK] button. →The downloading status window will be displayed. To cancel downloading the encoder information, click the [Cancel] button on the displayed down- loading status window.
33 Step 7 The message window will be displayed when down- load process ended. 1. Click the [OK] button. →The confirmation window will close. 2. Go to step 8. 1. Click the [OK] button on the error message window and check if the information on the Device regis- tration window has been edited correctly. Note: Check if the entered device information is correct. When the information has been edited correctly, the connected device or the version of the connect- ed device may be not compatible with this soft- ware. Refer to the Compatible devices section (page 5) for further information. 2. After confirming the edited information is correct and the compatible devices are connected, click the [Start…] button and complete the download. Step 8 Complete the setting of Device title. Step 9 Click the [Setup…] button. →The Camera setup window will be displayed. The following are descriptions about each item dis- played on the Camera setup window of the encoder. CH The camera channel numbers will be displayed. Title Enter the camera title. Enter up to 16 characters for the camera title. The following characters are unavailable for the cam- era title. ! $ % ’ < = > @ [ ]^ _ ` { | } ~ Default:Camera channel number
34 Type Select the camera type. PTZ camera:Cameras with the panning, tilting and zooming functions. Fixed camera:Cameras without the panning and tilt- ing functions. Default:PTZ camera Compression Select the image compression type. M-JPEG:Live images will be displayed in the M-JPEG format. MPEG-4:Live images will be displayed in the MPEG-4 format. Default:MPEG-4 Refresh interval (JPEG) Determine the refresh interval of the camera (number of images to be refreshed per second). The refresh interval setting can be set only when M- JPEG is selected for Compression. Auto/0.1 ips/0.2 ips/0.3 ips/0.5 ips/1 ips/2 ips/3 ips/ 5 ips/10 ips/15 ips/All When Auto is selected, an appropriate refresh inter- val will be applied according to the value set for Maximum refresh interval (JPEG/VGA) on the Performance page. When All is selected, the refresh interval will be 30 ips. Default: When M-JPEG is selected for Compression, Auto is the default. When Compression is other than M-JPEG, -- is the default. Notes: •The actual refresh interval may become slower than the set refresh interval depending on the net- work environment, the settings of the camera and the set maximum refresh interval on the Performance page. •Refer to the Set the maximum refresh interval [Performance] section (page 21) for how to set the maximum refresh interval. [OK] button The Camera setup window will be closed. Step 10 Click the [OK] button after completing the settings. →The Camera setup window will close. Notes: •The edited settings will not be saved and applied even when the Camera setup window is closed by clicking the [OK] button. To save and apply the settings, click the [Set] but- ton on the Device registration window after clos- ing the Camera setup window. •When a message window is displayed by clicking the [OK] button, refer to the Displayed messages and solutions section on page 73 and follow the instructions. Step 11 Click the [Set] button on the Device registration win- dow. →The Device registration window will close and the settings will be saved and applied. The registered encoder will be displayed in the list of the registered devices. Note: When a message window is displayed by clicking the [Set] button, refer to the Displayed messages and solutions section on page 73 and follow the instructions.
35 Step 1 Display the Registered device window of the encoder. (page 31) Step 2 Select the encoder whose information is to be edited, and then click the [Edit…] button. →The Device registration window will be displayed. Step 3 Click the [Set] button after editing the information. Refer to the Register an encoder [Basic setup] sec- tion (page 31) for further information. →The Device registration window will close and the settings will be saved and applied. Note: When a message window is displayed by clicking the [Set] button, refer to the Displayed messages and solutions section on page 73 and follow the instructions. Edit the registered encoder information [Basic setup]
36 Step 1 Display the Registered device window of the encoder. (page 31) Step 2 Select the encoder to be deleted. Step 3 Click the [Delete…] button. →The confirmation window will be displayed. Step 4 Click the [OK] button. →The device information will be deleted. Note: When a message window is displayed by clicking the [Delete…] button, refer to the Displayed mes- sages and solutions section on page 73 and follow the instructions. Delete the registered encoder [Basic setup]
37 Step 1 Click the [Device mng.] button. →The Registered device window will be displayed. Step 2 Click the [Camera] tab. →The Registered device window of the camera will be displayed. The following are descriptions about each item dis- played on the Registered device window of the cam- era. Registered device Titles of the registered cameras, model numbers and theirs addresses will be displayed in list form. Number of device Number of the registered cameras will be displayed. [Add…] button The Device registration window will be displayed. [Edit…] button The Device registration window of the camera select- ed from the list will be displayed. [Delete…] button The camera selected from the list will be deleted. Step 3 Click the [Add…] button. →The Device registration window will be displayed. Note: The [Add…] button will become unavailable when reached the maximum number of camera registra- tion. The following are descriptions about each item dis- played on the Device registration window of the cam- era. Address Enter the IP address of the camera. Enter up to 255 alphanumeric characters for the address. HTTP port number Enter a number from 1 to 65535 for the HTTP port number. Default:80 Use a proxy server Determine whether to use or not use a proxy server to connect the camera. ON:Use a proxy server OFF:Not use a proxy server Default:OFF Note: The proxy server address can be set on the [Basic setup] tab of the Comm page (page 54). Register a camera [Basic setup]
38 [Start…] button Camera information will be downloaded based on the settings of Address, HTTP port number and Use a proxy server. Model no. The model number contained in the downloaded cam- era information will be displayed. Unknown will be displayed when camera information is not downloaded yet. [Setup…] button The Camera setup window will be displayed. The [Setup...] button will be unavailable until camera information is downloaded. [Set] button The edited settings will be saved and applied. Step 4 Complete the settings of Address, HTTP port num- ber and Use a proxy server. Step 5 Click the [Start…] button. Important: When the settings of the setup menu of the camera are edited, download the camera information again. Note: When a message window is displayed by clicking the [Start…] button, refer to the Displayed mes- sages and solutions section on page 73 and follow the instructions. Step 6 Click the [OK] button. →The downloading status window will be displayed. To cancel downloading the camera information, click the [Cancel] button on the displayed down- loading status window.
39 Step 7 The message window will be displayed when down- load process ended. 1. Click the [OK] button. →The confirmation window will close. 2. Go to step 8. 1. Click the [OK] button on the error message window and check if the information on the Device regis- tration window has been edited correctly. Note: Check if the entered device information is correct. When the information has been edited correctly, the connected device or the version of the connect- ed device may be not compatible with this soft- ware. Refer to the Compatible devices section (page 5) for further information. 2. After confirming the edited information is correct and the compatible devices are connected, click the [Start…] button and complete the download. Step 8 Click the [Setup…] button. →The Camera setup window will be displayed. The following are descriptions about each item dis- played on the Camera setup window of the camera. Title Enter the camera title. Enter up to 16 characters for the camera title. The following characters are unavailable for the cam- era title. ! $ % ’ < = > @ [ ] ^ _ ` { | } ~ Default:1 Type Select the camera type. PTZ camera:Cameras with the panning, tilting and zooming functions. Fixed camera:Cameras without the panning and tilt- ing functions. The model numbers and their camera type are as fol- lows. Model no. Type WV-NF284 Fixed camera WV-NP24x Fixed camera WV-NP100x Fixed camera WV-NS202 PTZ camera WV-NS202A PTZ camera WV-NW484 PTZ camera WV-NP472 Fixed camera WV-NS32x PTZ camera WV-NW47x PTZ camera
40 Compression Select the image compression type. Only the MPEG-4 cameras can be selected. M-JPEG:Live images will be displayed in the M-JPEG format. MPEG-4:Live images will be displayed in the MPEG-4 format. Default: Model no. Compression WV-NF284 MPEG-4 WV-NP24x MPEG-4 WV-NP100x MPEG-4 WV-NS202 MPEG-4 WV-NS202A MPEG-4 WV-NW484 MPEG-4 WV-NP472 M-JPEG (cannot be changed) WV-NS32x M-JPEG (cannot be changed) WV-NW47x M-JPEG (cannot be changed) Resolution (JPEG) Select the resolution from the following. The resolution setting can be set only when M-JPEG is selected for Compression. Auto:Images whose resolution is VGA (640 x 480) will automatically be fit into the area when displaying on a 1-screen or a 4-screen or 6-screen. Images whose resolution is QVGA (320 x 240) will automatically be fit into the area when displaying on a 9-screen or a 16-screen. QVGA:Images whose resolution is QVGA (320 x 240) will automatically be fit into the area regardless of the screen pattern. VGA:Images whose resolution is VGA (640 x 480) will automatically be fit into the area regardless of the screen pattern. SXVGA* 1:Images whose resolution is SXVGA (1 280 x 960) will automatically be fit into the area regard- less of the screen pattern. Default: When M-JPEG is selected for Compression, Auto is the default. When Compression is other than M-JPEG, -- is the default. Model no. Resolution WV-NF284 Auto/QVGA/VGA WV-NP24x Auto/QVGA/VGA WV-NP100x Auto/QVGA/VGA/SXVGA*1 WV-NS202 Auto/QVGA/VGA WV-NS202A Auto/QVGA/VGA WV-NW484 Auto/QVGA/VGA WV-NP472 --*2 WV-NS32x --*2 WV-NW47x --*2 *1: When Partial is selected for the scan mode of the camera, the resolution will be 960 x 720. *2: Cannot select any parameter for Resolution (JPEG). Refresh interval (JPEG) Determine the refresh interval of the camera (number of images to be refreshed per second). The refresh interval setting can be set only when M- JPEG is selected for Compression. Auto/0.1 ips/0.2 ips/0.3 ips/0.5 ips/1 ips/2 ips/3 ips/ 5 ips/10 ips/15 ips/All When Auto is selected, an appropriate refresh inter- val will be applied according to the value set for Maximum refresh interval (JPEG/VGA) on the Performance page. When All is selected, the refresh interval will be 30 ips. Default: When M-JPEG is selected for Compression, Auto is the default. When Compression is other than M-JPEG, -- is the default. Notes: •0.1 ips, 0.2 ips, 0.3 isp and 0.5 ips may be unavailable depending on the model of the camera. •The actual refresh interval may become slower than the set refresh interval depending on the net- work environment, the settings of the camera and the set maximum refresh interval on the Performance page. •Refer to the Set the maximum refresh interval [Performance] section (page 21) for how to set the maximum refresh interval. [OK] button The Camera setup window will be closed.