Have a look at the manual Panasonic Network Camera Server Bb Hcs301a Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Operating Instructions [For assistance, please call: 1-800-272-7033] 121 2.25 Notifying Setup of an Alarm Log Once a day, an alarm log sent at a specified time can be checked. To enable Alarm Log, set Alarm or Motion Detection for Trigger Setting and check [Enable]. 1.Click [Alarm Log] on the Setup page. 2.Set each parameter. 3.Click [Save] to save the settings. Clicking [Cancel] cancels your settings without saving changes. 4.Click [Go to Alarm Log page]. The Alarm Log page is displayed. Note If you change a setup of operation and click [Save], new alarm logs are deleted.
Operating Instructions 122 SettingDescription A setup of operation Alarm log operation can be set here. Time Set the date and time to send alarm logs via E-mail. SMTP Server IP Address or Host Name *1 *1But [Space], [], [], [&], [] are not available. If you set the server IP address, set 4 digits (0—255) and 3 periods such as 192.168.0.253. But 0.0.0.0 and 255.255.255.255 are not available. Or set a host name (0—255 characters). An IPv6 address can be set. Por t N o. Enter a number (1—65535). Usually set to 25. POP3 Server IP Address or Host Name *1 If you set the server IP address, set 4 digits (0—255) and 3 periods such as 192.168.0.253. But 0.0.0.0 and 255.255.255.255 are not available. Or set a host name (0—255 characters). An IPv6 address can be set. Por t N o. Enter a number (1—65535). Usually set to 110. Login ID*2 *2But [] is not available. If your ISP requires a login ID to log in to a POP3 server, set it (0—63 characters). Password*2 If your ISP requires a password to log in to a POP3 server, set it (0—63 characters). Reply E-mail Address*2 Set the senders E-mail address. We recommend you to set the administrators E-mail address. Destination E-mail Address 1-3*2 Set the destination E-mail address (up to 3). Subject*2 Enter a subject with ASCII characters (see page 163) or characters in each language (0—44 characters for a 1-byte character and 0—22 characters for a 2-byte character).
Operating Instructions [For assistance, please call: 1-800-272-7033] 123 2.26 Changing Initial Settings on the Single Camera page or the Multi-Camera page The Image Display page allows you to change initial settings (display settings when a user accesses this product) of image resolution, image quality and refresh interval. You can display a time stamp on the image. The initial language can be selected from eight languages. The banner can be displayed for administrator or general users or both. 1.Click [Image Display] on the Setup page. 2.Set each parameter. Clicking [Cancel] cancels your settings without saving changes.
Operating Instructions 124 SettingDescription Image Resolution Select the image resolution. 640 × 480 pixels (Only for the Single Camera page) 320 × 240 pixels (default) 160 × 120 pixels (Only for the Multi-Camera page) Image Quality Select the image quality. [Favor Clarity] optimizes for good quality. [Standard] offers standard quality. (default) [Favor Motion] optimizes for enhanced motion. Refresh Interval Select a refresh interval. Motion, 3 s, 5 s, 10 s, 30 s, and 60 s Time stamp setting You can display a time stamp on the upper left side of the image. Select from [Enable] or [Disable]. Notes If you enable this feature, the time is also stamped on the buffered image. Set AM/PM format and 24H format on the Date and Time page. Language Select the initial language from English, French, German, Italian, Spanish, Russian, Simplified Chinese or Japanese. The selected language is displayed as the initial language on the Top, Single Camera, Multi- Camera and Buffered Image pages. If you select English or Japanese, all pages can be changed. But if you select other language, the Setup, Maintenance and Support pages are displayed only in English. Banner Display When this product accesses the Internet, the banner displays product information about this product or announcements about the latest firmware, etc. from Panasonic. Checking [Display] for Administrator is particularly recommended. When checked, the banner is displayed for administrator or general users or both. The banner is displayed only on the Single Camera page (see page 16).
Operating Instructions [For assistance, please call: 1-800-272-7033] 125 3.Click [Save] when finished. New settings are saved. When finished, Success! is displayed. 4.Click [Go to Image Display page]. The Image Display page is displayed.
Operating Instructions 126 2.27 Configuring Multiple Images To view images on the Multi-Camera page, this products or the Panasonic Network Cameras IP address and camera name must be configured on the Multi-Camera Setup page. These configurations are required to use the Multi-Camera page. Up to 12 cameras can be configured. 1.Click [Multi-Camera] on the Setup page. 2.Click Add. Notes If you click the number, the modification page is displayed. The setting can be modified or deleted on it. If you configured multiple cameras, you can change the number. Select the number, and click [Move]. 3.Set each parameter. Clicking [Cancel] cancels your settings without saving changes.
Operating Instructions [For assistance, please call: 1-800-272-7033] 127 Notes Set the local IP address and port number for this product on the same LAN. If this product is accessed from the Internet, be sure to use the global IP address. In this situation, local IP addresses such as 192.168. . cannot be used. 4.Click [Save] when finished. New settings are saved. The Multi-Camera Setup page is displayed. SettingDescription Display Check the box to enable the image display. IP Address*1 or Host Name*2 Set the IP address or the host name to enable the image display. Po r t N o. Set the port number (1—65535). Camera Name*3 The name is displayed only on the Multi-Camera page. *1In IPv4, set 4 digits (0—255) and 3 periods such as 192.168.0.253. But 0.0.0.0 and 255.255.255.255 are not available. In IPv6, set the host name.*2Enter ASCII characters for the host name (see page 163). But [Space], [], [], [#], [&], [%], [=], [+], [?], [] are not available. Enter 1—255 characters.*3Enter ASCII characters (see page 163) or characters in each language (1—15 characters for a 1-byte character and 1—7 characters for a 2-byte character). But [Space], [], [], [#], [&], [%], [=], [+], [?], [:], [] are not available.
Operating Instructions 128 2.28 Specifying Operation Time The Operation Time page allows you to limit the operation time. The image turns to a gray screen outside the operation time. Notes If you wrongly set the time period, your privacy may be seen. Confirm the time period after the setup. If you access this product as an administrator, you can view the image outside the time period. 1.Click [Operation Time] on the Setup page. 2.Click [No.] to set the operation time. Note If No. 1—7 are disabled, this product can always be operated. 3.Check [Enable], set the time. Clicking [Cancel] takes you back to the previous page.
Operating Instructions [For assistance, please call: 1-800-272-7033] 129 4.Click [Save] when finished. New settings are saved. The Operation Time page is displayed. About Operation Time In the operation time settings, the enabled settings take priority over the disabled settings. Therefore, if Monday or Tuesday is disabled in a setting but enabled in other settings, this product can be operated on both Monday and Tuesday. SettingDescription Enable Check the box to enable the setting. Clear the box to disable it. A day of the week Check the box to enable the day. Clear the box to disable it. Operation Time Select the [Always] option when you do not specify the time period. If you specify the time period, select the time period option and set the time period.
Operating Instructions 130 2.29 Controlling External Output Terminal The digital output terminal allows you to control the external devices. You can change the initial status of the output signal. Note Connect the external devices to this product. 1.Click [External Output] on the Setup page. 2.Click [Save] when finished. Clicking [Cancel] cancels your settings without saving changes. New settings are saved. When finished, Success! is displayed. 3.Click [Go to External Output Control page]. The External Output Control page is displayed. SettingDescription External Device Control Output If you check [Open], the internal transistor turns off and the external output terminal gets high impedance (open collector) when this product powers up. If you check [Short to GND], the internal transistor turns on and is electrically short-circuited to GND pin when this product powers up. The external output terminal gets low impedance (0 V). Button name modification You can change the output control button names on the operation bar. You can name the button depending on your external devices.