Panasonic Mpeg2 Encoder Wj Gxe900 Operating Instructions
Here you can view all the pages of manual Panasonic Mpeg2 Encoder Wj Gxe900 Operating Instructions. The Panasonic manuals for TV Receiver are available online for free. You can easily download all the documents as PDF.
Page 102
102 RESETTING THE ALARM / DISPLAYING THE ALARM STATUS Displays the status of the alarm or resets the alarm against the encoder. The bit rate of the streaming video and audio data returns to the set value by resetting the alarm that sets the status of the alarm to OFF. When two or more alarms occurred, the bit rate of the latest alarm will be applied. The camera preset control will not be performed when resetting. ■Format ■Important Notices •"/control4?alm=(parameter value)&ch=(parameter value)"....
Page 103
103 ■Response ●Response of alarm reset ●Response of displaying alarm status ■Examples 1. To reset the alarm occurred at the contact input port 1 http://192.168.0.10/control4?alm=reset&ch=01 2. To reset the video loss alarm occurred at the VIDEO IN 3 http://192.168.0.10/control4?alm=reset&ch=11 3. To display the alarm status http://192.168.0.10/control4?alm=state&ch=00 HTTP /1.1 XXXXXXXXXXXXX CR LF Cache-Control: no-cache CR LF Content-Type: text/plain CR LF Content-Length: XX CR LF(Store the octet...
Page 104
104 DISPLAYING THE CONTACT INPUT STATUS Displays the status of each contact input port. ■Format ■Response HTTP /1.1 200 OK CR LF Cache-Control: no-cache CR LF Content-Type: text/plain CR LF Content-Length: XX CR LF(Store the octet number of the Message-Body decimally) CR LF DI1: xxx CR LF(Status of the contact input port 1) DI2 : xxx CR LF(Status of the contact input port 2) DI3 : xxx CR LF(Status of the contact input port 3) DI4 : xxx CR LF(Status of the contact input port 4) (xxx : High or...
Page 105
105 DISPLAYING THE STATUS OF VIDEO LOSS Displays the receiving status of the video sync signals from camera or the VTR connected to the VIDEO IN connector of the encoder. When the power of the camera connected with the video cable is off, the status will be OFF. ■Format ■Response HTTP /1.1 200 OK CR LF Cache-Control: no-cache CR LF Content-Type: text/plain CR LF Content-Length: XX CR LF(Store the octet number of the Message-Body decimally) CR LF VI1: xxx CR LF(Status of VIDEO IN 1) VI2 : xxx CR...
Page 106
106 MUTING THE AUDIO It is possible to mute audio temporarily, or resume muted audio. ■Format ■Response ■Important Notice •"audio=out&ch=(parameter value)&mute=(parameter value)" (Required) ■Item List Item Parameter name Parameter value Description Audio mute audio out Identifier to mute audio AUDIO OUT connector number ch 01 - 04 Select a AUDIO OUT connector number Audio mute control mute on, off on: Stop audio output off: Audio output ■Examples 1. To resume the muted audio output from the AUDIO...
Page 107
107 MULTISCREEN DISPLAY Designates image to be displayed on the monitor connected to the QUAD connector by the CGI commands. It is possible to select whether to display in multiscreen (quad) or to display one of the 4 image sources. ■Format ■Response ■Important Notice •"video=out & ch=(parameter value)" (Required) ■Control Item List Item Parameter name Parameter value Description Multiscreen video out Identifier to display multichannel VIDEO OUT channel ch 01 - 05 Select one of the VIDEO OUT...
Page 108
108 CONTROLLING THE CONTACT OUTPUT It is possible to designate the output port, output type (open/close), and output time of the control pulse which is supplied from the contact output port of the encoder. ■Format ■Response ■Important Notice •The output time will be invalid when "momentary" is selected for the output mode. ■Item List Item Parameter name Parameter value Description Output port PIO 1 - 4 Designate the output port Output mode OUT latch Supply the pulse from the output port dur- ing...
Page 109
109 ■Examples 1. Close output for 1 second for the port 1 http://192.168.0.10/cgi-bin/pioctrl.cgi?com=set_pio&PIO=1&OUT=latch&TYPE=close &TIME=10&submit=ACTION 2. Open output for 15 seconds for the port 2 http://192.168.0.10/cgi-bin/pioctrl.cgi?com=set_pio&PIO=2&OUT=latch&TYPE=open &TIME=150&submit=ACTION 3. Trigger close output for the port 3 http://192.168.0.10/cgi-bin/pioctrl.cgi?com=set_pio&PIO=3&OUT=momentary&TYPE=close &submit=ACTION 4. Trigger open output for the port 4...
Page 110
110 RESTARTING THE ENCODER / DECODER It is possible to restart the encoder/decoder using the CGI commands. ■Format ●Restarting the encoder ●Restarting the decoder ■Response ■Important Notice The user name and the password authentication will be required when trying to restart the encoder/decoder. Enter a user name with access level 1 (ADMINISTRATOR) and the password registered to the encoder/decoder to be restarted. ■Example •Restarting the decoder...