    							61
    Note:When you use WJ-HD300 Series, start playback
    before pressing the GO TO LAST button.
     WV-CU360C/CJ
    This operation is not available.
     Recorder Control End
    Note:Before this operation, stop playback or search play-
    back surely.
    To finish recorder control, select a camera.
    The monitor display will become the status before recorder
    control.
     Recorder Selection
    Before recorder control procedures not described in this
    chapter, you need to select a recorder in advance. In the
    following example, you will open SETUP MENU of Recorder
    16.
     WV-CU950/650
    1. Enter the desired recorder number by pressing the
    numeric buttons. The entered number will appear on
    the LCD.
    2. Press the RECORDER button. The recorder will be
    selected.
    3. Press the MENU button repeatedly until System Setup
    appears on the LCD.
    4. Press the F1 button. SETUP MENU of recorder will be
    displayed on the selected monitor.
    Note:To close the SETUP MENU, press the F2 button.
     WV-CU360C/CJ
    1. Enter the desired recorder number by pressing the
    numeric buttons. The entered number will appear on
    the LED display.
    2. Press the RECORDER button. The recorder will be
    selected.
    3. Press the SETUP button while holding down the SHIFT
    button. SETUP MENU of recorder will be displayed on
    the selected monitor.
    Note:To close the SETUP MENU, press the SETUP button
    while holding down the SHIFT button.
     Note
    If a selected recorder directly connects an external monitor,
    black screen will be displayed on the monitor with the mes-
    sage RECORDER CONTROL. Refer to p. 30 for connec-
    tion.  
    						
    							62
     Descriptions of Sequence
    Sequence is the function to switch camera images automatically.
    There are two sequences:
    •Tour sequence
    •Group sequence
     Tour Sequence
    Camera images are displayed on a selected monitor, and they are sequentially switched according to the setting. 
    •Up to 32 tour sequences can be registered.
    •Up to 64 steps can be set for a tour sequence.
     Group Sequence
    Camera images are displayed on two or more monitors, and they are sequentially switched according to the setting. 
    •Up to 8 group sequences can be registered.
    •Up to 32 steps can be set for a group sequence.
     Group Preset
    Spot camera images are simultaneously displayed on two or more assigned monitors. Up to 24 (Group Sequence 9 to 32)
    group presets can be registered.
    RUNNING SEQUENCE
    Monitor 1
    Monitor 2
    Monitor 3Step 1 Step 2 Step 3Camera 1
    Preset 1
    Camera 10
    Preset 2
    Camera 100
    Preset 3Camera 5
    Camera 20
    Preset 10
    Camera 300Camera 7
    Camera 50
    Camera 900
    Preset 200
    Displayed for 2 seconds Displayed for 10 seconds Displayed for 30 seconds
    ......
    ......
    ...... 
    						
    							63
    Setting item
    LCN (Logical Camera Number) 
    Preset
    AUX1/2
    DwellParameter Remarks
    1 to 999
    1 to 256
    ON, OFF, - -
    1 to 30 secCamera position numbers are also avail-
    able for parameters. (CAM-P)
    –
    Dwell time to display each camera
    image
    (Group preset has no sequence steps,
    and Dwell setting is not available.)
     Sequence Setting
    Sequence setting is performed in Sequence of WJ-SX650 Series  Administrator Console. The following settings are available
    for each sequence step.
    Note:Preset and AUX1/2 will not be activated for cameras selected by operators with higher priority or restricted by the cam-
    era access setting  
    						
    							64
     Tour Sequence
    WV-CU950/650
    1. Enter the desired sequence number by pressing the
    numeric buttons. The entered number will appear on
    the LCD.
    2. Press the TOUR SEQ button. The tour sequence will be
    activated.
     WV-CU360C/CJ
    1. Enter the desired sequence number by pressing the
    numeric buttons. The entered number will appear on
    the LED display.
    2. Press the TOUR SEQ button. The tour sequence will be
    activated.
     Group Sequence/Preset
    WV-CU950/650
    1. Select a monitor assigned for desired group
    sequence/preset. (Refer to p. 57 Monitor Selection.)
    2. Enter the desired sequence number by pressing the
    numeric buttons. The entered number will appear on
    the LCD.
    3. Press the GROUP SEQ button while holding down the
    SHIFT button. The group sequence will be activated.
     WV-CU360C/CJ
    1. Select a monitor assigned for desired group
    sequence/preset. (Refer to p. 57 Monitor Selection.)
    2. Enter the desired sequence number by pressing the
    numeric buttons. The entered number will appear on
    the LED display.
    3. Press the GROUP SEQ button. The group sequence will
    be activated.
    Notes:
    •If you have specified Group Sequence 9 to 32 in Step
    2, group preset will be activated. The system status will
    be the same as that after camera selection.
    •Group sequence/preset will not be activated for moni-
    tors selected by operators with higher priority or
    restricted by the monitor access setting 
    •When one of the monitors assigned for the active group
    sequence is controlled by a higher-priority operator,
    you cannot control the monitors. (Monitor busy) 
    						
    							65
     Sequence Pause
    You can pause an active tour or group sequence. When a
    group sequence is paused on a monitor, all sequences will
    be simultaneously paused on other monitors.
    1. Press the SEQ PAUSE*
    1(or PAUSE*2) button.
    Sequence will be paused.
    2. Press the SEQ PAUSE*
    1(or PAUSE*2) button again to
    restart the sequence.
    *
    1WV-CU950/650
    *2WV-CU360C/CJ
    Available operations during sequence pause
    •Sequence step forward/backward
    You can move the sequence one frame to the next or
    previous step by pressing the + or – button.
    •Camera control
    You can control the camera whose image is being dis-
    played on the monitor.
     Sequence Stop
    When a tour or group sequence is stopped, the camera at
    the stopped step will be selected. When a group sequence
    is stopped on a monitor, all sequences will be simultane-
    ously stopped on other monitors.
     WV-CU950/650
    Press the SEQ STOP button while holding down the SHIFT
    button.
    Sequence will be stopped.
     WV-CU360C/CJ
    Press the STOP button.
    Sequence will be stopped.
    Note
    Sequence will also be stopped when you select a camera
    during the sequence is activated. Then, the image of
    selected camera will be displayed on the monitor. 
    						
    							66
    ALARM DESCRIPTIONS
    Alarm Occurrence
    When this unit accept an alarm input signal (terminal alarm, camera alarm, recorder alarm, serial alarm, or video loss), an
    alarm event (tour sequence, etc.) is activated automatically. Each alarm input signal is associated with an alarm event setting.
    (The setting activates the alarm input signal and alarm event.) Up to 1 024 alarm event settings are available. The alarm event
    setting is performed in Alarm – Alarm Event of WJ-SX650 Series  Administrator Console.
    By performing the settings of Alarm Event, the following events will be activated when this unit accepts an alarm input signal.
    •Alarm event information will be displayed on the associated monitors (Refer to p. 13 Monitor Display Information.)
    •Depending on the setting of Display Mode, camera images will be displayed, or sequences will be activated on the asso-
    ciated monitors. In this document, these actions are mentioned as the alarm mode, and pictures displayed during the
    alarm mode is mentioned as alarm pictures.
    •Depending on the setting of Recording Source LCN, event recording will be activated. (Recording will follow the com-
    mand alarm setting and event recording setting of recorder. Refer to the operating instructions of recorder for details.)
    •Depending on the setting of Alarm Output, alarm output signal will be supplied from the video output board, and external
    alarm devices (buzzer, etc.) can be activated.
    Notes: 
    •To activate terminal alarm output signals, perform settings of No.1 to 64. No.65 and greater are assigned for serial
    commands. 
    •To activate serial alarm output signals, serial command settings are required. The settings are performed in
    Communication – Serial Command of WJ-SX650 Series Administrator Console. 
    •ALARM indicators of all system controllers blink.
    •Up to 10 000 alarm records are saved chronologically.  The latest 1 000 alarm records can be displayed as the alarm his-
    tory on the monitor. (Refer to p. 69 Alarm History Display.) The Alarm History can be downloaded from the PC to the unit.
    •Alarm information is notified to the PC in serial commands. The serial command setting is performed in Communication –
    Serial Command of WJ-SX650 Series Administrator Console. 
    Terminal alarm setting
    No.11(Dish)No.10 (Pot)
    No.1 (Entrance)
    Sensor 
    system
    Alarm Input 256
    Matrix Switcher WJ-SX 650650
    Alarm input signal 
    from a sensor
    ALARMTIMERHDD 2ERRORHDD 1 ALARM
    SUSPEND
    ALARM
    RESETOPERATEMONITOR1
    MONITOR2159132610/014371115481216SEQ SHIFT OSDPA N /
    TILTSTOPPLAY PAUSEREC - REC STOP
    ZOOM/
    FOCUSTEXTCOPYDISK SELECTEL-ZOOMMARKLOGOUTIRIS
    PRESET
    /AUTOA-B
    REPEATGOTO
    LASTLISTEDSEARCH
    BUSYSETUP
    /ESCSETREV–+FWDPULLDigital Disk Recorder
    WJ-HDPA N / T I LTSLOW
    Infrared sensor Preset Position 1
    (Zooming in No.1 (Entrance))
    Monitor 5 Terminal Alarm 
    256This unit Camera 100
    PC Alarm Output 50
    Recorder 1Records the image 
    of Camera 100.
    (Recording follows  
    the command alarm 
    setting and event 
    recording setting of 
    recorder.)
    Notifies the 
    alarm event 
    occurrence.
    No. Display ModeSpot
    MonitorRecording
    Source (LCN)Alarm Output
    LCN Preset
    256 SPOT 100 1 5 100 50 
    						
    							67
    Alarm Modes
    The following alarm modes (Display Mode settings) are
    available. (Alarm mode follows the setting of Display
    Mode.)
    Spot
    The image of associated camera will be displayed on the
    monitor. Preset position or auxiliary control will be activated.
    The following alarm modes (=patterns to display alarm pic-
    tures on a monitor) are available. (Regardless of alarm
    modes, alarms occur to all the associated cameras.) The
    alarm mode setting is performed in Alarm – Alarm Mode
    of WJ-SX650 Series Administrator Console or the ALARM
    menu of SETUP MENU.
    • Sequence mode
    Alarm pictures are sequentially displayed on the associated
    monitor.
    • Earliest mode
    The earliest alarm picture is displayed on the associated
    monitor.
    • Latest mode
    The latest alarm picture is displayed on the associated
    monitor.
    Tour Sequence
    Tour sequence is activated on the associated monitor. 
    Group Sequence/Preset
    Group sequence is activated on the associated monitors. 
    OFF
    Only the alarm information is displayed on the associated
    monitor. Alarm does not occur to monitors and cameras.
    Notes:
    •When a tour sequence, group sequence, or group pre-
    set is activated as an alarm event, the earlier alarm
    event on the monitor will be reset. 
    •When 33 or more alarms (spot mode) occur to a moni-
    tor, older alarms will be reset chronologically. 
    •After occurrence, the same alarm will be suspended for
    5 seconds.
    •By the alarm schedule setting, alarm events can be
    deactivated in the specified periods. The alarm sched-
    ule setting is performed in Alarm – Alarm Event of
    WJ-SX650 Series Administrator Console.
    Video Loss
    To display the video loss information on associated moni-
    tors and save the video loss history without making alarms
    occur to monitors and cameras, set Display Mode to OFF. 
    Note:If Alarm A (Display Mode is OFF) occurs while
    Alarm Bs (Display Mode is Spot, Tour Sequence or
    Group Sequence) are being activated, the Alarm A
    information will be displayed on the monitor after all
    Alarm Bs have been reset.
    Alarm 1Alarm 2
    Alarm 3Alarm 4
    Alarm 4
    Alarm 1 
    						
    							68
    ALARM CONTROL
    Alarm Acknowledgement (ACK)
    By acknowledging an alarm occurrence on an associated
    monitor, you can control alarm pictures.
    WV-CU950/650
    While a monitor in the alarm mode status is selected, press
    the ACK button. (During the alarm mode status, Alarm
    sign is blinking on the LCD.)
    The alarm event will be acknowledged. (Alarm sign will
    change to steady light.)
    WV-CU360C/CJ
    While a monitor in the alarm mode status is selected, press
    the ACK button. (During the alarm mode status, the alarm
    number is blinking on the LED display.
    The alarm will be acknowledged. (The alarm number will
    change to steady light.)
    In the ACK status, the following operations are available.
    Camera Control
    You can control panning/tilting of cameras, or move cam-
    eras to preset positions, etc.
    Alarm Picture Change
    When two or more alarms are occurring, you can change
    alarm pictures displayed on the monitor in order or reverse
    order.
    WV-CU950/650
    To change alarm pictures on the monitor, press the + or –
    button. The alarm pictures will be displayed in order or
    reverse order.
    WV-CU360C/CJ
    To change alarm pictures on the monitor, press the NEXT
    or PREV button. The alarm pictures will be displayed in
    order or reverse order.
    Alarm Individual Reset
    You can reset each acknowledged alarm separately, and
    return to the status before alarm occurrence. While two or
    more alarms are occurring, the system will remain in the
    alarm mode even after an alarm reset.
    To reset an acknowledged alarm, press the ACK button.
    The alarm will be reset.
    Notes: 
    •An alarm whose display mode setting is OFF will not be
    the ACK status. The alarm will be reset by every press-
    ing the ACK button.
    •If AUTO RESET has been set to ON, alarms will be reset
    automatically after the specified time. AUTO RESET set-
    ting is performed in Alarm – Alarm Mode of WJ-
    SX650 Series Administrator Console or the ALARM
    menu of SETUP MENU. Refer to p. 49 ALARM of SETUP
    MENU.
    Alarm Monitor Reset
    You can reset all the alarms occurred to the selected moni-
    tor.
    While the selected monitor is in the alarm mode status,
    press the ALM RESET*
    1(or RESET*2) button. All the alarms
    occurred to the monitor will be reset, and the monitor dis-
    play will return to the status before the alarm occurrence.
    *
    1WV-CU950/650
    *2WV-CU360C/CJ
    Note:Alarm monitor reset is also available by supplying
    Alarm Recover Input signals to the unit. (Refer to p. 36.)
    Alarm All Reset
    You can reset all the alarms occurred to the system.
    Press the ALM ALL RESET*
    1(or ALL RESET*2) button while
    holding down the SHIFT button. All the alarms occurred to
    the system will be reset. 
    						
    							69
    *1WV-CU950/650
    *2WV-CU360C/CJ
    Notes:
    •Alarm all reset will also be conducted when setting
    changes are performed in SETUP MENU or WJ-SX650
    Series Administrator Console.
    •To reset the alarms occurred to recorders, perform
    alarm all reset. Alarm all reset is available even while no
    alarms are occurring.
    Return to Alarm Mode Status
    You can recover from the ACK status to the alarm mode
    status.
    WV-CU950/650
    Press the ACK button while holding down the SHIFT button. 
    The alarm mode will be recovered.
    WV-CU360C/CJ
    This operation is not available.
    Alarm Suspension
    You can suspend the system from accepting alarm input
    signals when you do not want to be disturbed. (Alarm will
    also be suspended for recorders.)
    1. Press the ALM SUSPEND*
    1(or SUSPEND*2) button
    while holding down the SHIFT button. 
    The alarm will be suspended.
    2.
    To cancel the alarm suspension mode, press the ALM
    SUSPEND*1(or SUSPEND*2)button while holding down
    the SHIFT button again.
    *1WV-CU950/650
    *2WV-CU360C/CJ
    Alarm History Display
    The latest 1 000 alarm records (date, time and details) can
    be displayed as the alarm history on an active monitor.
    Note:Alarm History Display is not available on monitors in
    the alarm mode or during recorder selection.
    WV-CU950/650
    Press the ALM RECALL button. The Alarm History Display
    will appear on the selected monitor.
    WV-CU360C/CJ
    Press the OSD and ALM H buttons at a time. The Alarm
    History Display will appear on the selected monitor.
    Details on Alarm History Display
    ∗ beside the time indicates daylight saving time (sum-
    mer time).
    The following items are display details.
    • ALARM (Highlighted for reset alarms)
    T-001 to 256:Terminal alarm
    (Example: For T-001, 001 means the number of
    alarm input signal accepted by the ALARM IN port
    of video input board.)
    C-001 to 999:Camera alarm
    (Example: For C-001, 001 means the number of
    camera supplying an alarm input signal to the unit.)
    R-001 to 999:Recorder alarm
    (Example: For R-001, 001 means the number of
    camera associated with the recorder supplying an
    alarm input signal to the unit.)
    S-0001 to 1024:Serial alarm
    (Example: For S-0001, 0001 means the serial com-
    mand alarm input number.)
    V-001 to 999:Video loss
    (Example: For V-001, 001 means the number of
    camera to which video loss has occurred)
    ALL:Alarm all reset
    :Alarm suspension ON/OFF
    S
        ALARM HISTORY                1 of 100
     M  D  Y  H  M  S  ALARM     ACTION   REC
    Aug31/06
    ∗11:59:00PM ALL       12345   K4-8
    Aug31/06∗11:58:00PM C-999     M32 C100 001
    Aug31/06∗11:57:00PM V-001     M03 T32  256
    Aug31/06∗11:56:00PM           POWER
    Apr15/05∗09:15:25AM                      POWER
    Apr15/05∗09:15:25AM R-003
    Apr15/05∗09:13:54AM S-0002    M10*G32  ———
    Apr15/05∗09:12:32AM T-001     M20 ———  999
    Jan02/05 03:05:10PM S         56789    PC
    Jan01/05 03:04:08PM S         101      PSD
    T-TERMINAL  C-CAMERA         R-RECORDER
    S-SERIAL    V-VIDEO LOSS     SSUSPEND 
    						
    							70
    • ACTION
    POWER:The unit is powered on. (Highlighted: Power
    off) 
    M01 to 32:Alarm occurred to Monitor 1 to 32. (For
    group sequence and group preset, the smallest
    monitor number is displayed with ∗.)
    C001 to C999:Camera 001 to Camera 999 was activat-
    ed for spot mode.
    T01 to 32:Tour Sequence 1 to 32 was activated.
    G01 to 32:Group sequence (or Group preset) 1 to 32
    was activated.
    Notes:
    •User ID and Controller information is displayed for
    an alarm reset or suspended by an operator. (They
    are not displayed for auto reset.)
    •User ID and controller No. will be highlighted to
    indicate alarm reset or alarm suspension OFF.
    • REC
    Recording Source (LCN) associated with the alarm event
    is displayed.
    Refer to p. 73 Lists of Operations and Functions for opera-
    tions while the Alarm History Display is displayed on the
    monitor. 
    						