Panasonic Matrix Switcher Wj Sx650p Operating Instructions
Have a look at the manual Panasonic Matrix Switcher Wj Sx650p Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
51 Notes: •ON is not available for recorders when camera input channels are set for RS-485 cameras. To activate recorder connec- tions, delete the RS-485 camera settings. (Refer to p. 53.) •For camera input channels to supply video input signal from recorders, set VD2 and DATA to OFF. The VD2 and DATA set- tings are performed in VD2/DATA/CABLE COMPENSATION. (Refer to p. 53.) •Set LCN parameters surely for these camera input channels, even though these channels accept video input signals from recorders. Without LCN settings, recorder selection is unavailable. The channel settings are performed in System – Recorder of WJ-SX650 Series Administrator Console. •Be sure to connect the recorders to the specified DATA ports in the daisy chain. (Refer to p. 32 for connections.) •Be sure to supply the video input signals from recorders to the specified camera input channels. (Refer to p. 30 for con- nections.) RECORDER No. 1CAMERA IN No. 32CAM (Camera input channel No.: Video Input board 1 to 8) INPUT BOARD 1 32 64 96 128 160 192 224 256 2 31 31 63 95 127 159 191 223 255 3 30 30 62 94 126 158 190 222 254 4 29 29 61 93 125 157 189 221 253 5 28 28 60 92 124 156 188 220 252 6 27 27 59 91 123 155 187 219 251 7 26 26 58 90 122 154 186 218 250 8 25 25 57 89 121 153 185 217 249 9 24 24 56 88 120 152 184 216 248 10 23 23 55 87 119 151 183 215 247 11 22 22 54 86 118 150 182 214 246 12 21 21 53 85 117 149 181 213 245 13 1420 1920 19 51 83 115 147 179 211 243 15 18 18 50 82 114 146 178 210 242 16 17 17 49 81 113 145 177 209 24152 84 116 148 180 212 244 INPUT BOARD 2INPUT BOARD 3INPUT BOARD 4INPUT BOARD 5INPUT BOARD 6INPUT BOARD 7INPUT BOARD 8
52 SYSTEM You will perform the system settings required to transmit data between the unit and connected devices. When you select SYSTEM on the top menu, the following menu is dis- played. SYSTEM Menu • DATA PORT DATA PORT menu will be displayed. You will select the DATA port types according to the connected devices. • SERIAL PORT Select the communication speed of SERIAL port. (The fac- tory default is 38 400 bps.) 4 800 bps/9 600 bps/19 200 bps/38 400 bps Other parameters (COMMUNICATION STATUS) are as fol- lows. (Setting change is not available.) Data bit:8 (bits) Parity check:NONE Stop bit:1 (bit) • VD2/DATA/CABLE COMPENSATION VD2/DATA/CABLE COMPENSATION menu is displayed. You will perform the settings for VD2, camera control signal (DATA), and cable compensation. • RS485 CAMERA RS485 CAMERA menu is displayed. You will set the RS-485 port numbers and unit numbers for the RS-485 cameras. DATA PORT Menu • TYPE Select the DATA port types according to the connected devices. TMNL1 to 8:Select this when using the DATA port for sys- tem controller in the terminal mode. PSD:Select this when using the DATA port for system con- troller in the PS·Data mode. HDR1 to 4:Select this when connecting a recorder to the DATA port. The available port settings are as follows. DATA1:TMNL1 /PSD (The factory default is TMNL1.) DATA2:TMNL2 (The factory default is TMNL2.) DATA3:TMNL3/HDR1 (The factory default is HDR1.) DATA4:TMNL4/HDR2 (The factory default is HDR2.) DATA5:TMNL5 (The factory default is TMNL5.) DATA6:TMNL6 (The factory default is TMNL6.) DATA7:TMNL7/ HDR3 (The factory default is HDR3.) DATA8:TMNL8/ HDR4 (The factory default is HDR4.) • COMM. Select the communication speed. (The factory default is 9 600 bps.) 4 800 bps/9 600 bps/19 200 bps Parameters of COMMUNICATION STATUS are as follows. (Setting change is not available.) Data bit:8 (bits) Parity check:NONE Stop bit:1 (bit) Note:When changing the communication speed, conform the communication speed settings to that of the con- nected devices. 500 SYSTEM 510 DATA PORTO 520 SERIAL PORT COMMUNICATION STATUS 38400 (8/ NONE/1) 530 VD2/DATA/CABLE COMPENSATIONO 540 RS485 CAMERAO B 510 DATA PORT DATA TYPE COMM. OUTPUT BOARD1 1 TMNL1 9600 2 PSD 9600 3 HDR1 9600 4 HDR2 9600 OUTPUT BOARD2 5 TMNL5 9600 6 TMNL6 9600 7 HDR3 19200 8 HDR4 19200 COMMUNICATION STATUS 8/ NONE/1 DATA=DATA(TMNL/PCD/HDR)
53 VD2/DATA/CABLE COMPENSATION Menu • INPUT BOARD Select a video input board from 1 to 8. (The factory default is 1.) • VD2 Select ON or OFF. (The factory default is ON.) ON:Sends the VD2 timing pulse with the camera output signal. OFF:Not sends the VD2 timing pulse with the camera out- put signal. • DATA Select ON or OFF. (The factory default is ON.) ON:Sends the control data with the camera output signal via the coaxial cable. OFF:Not sends the control data with the camera output signal via the coaxial cable. • CABLE Perform the settings to compensate for the video signal transmission loss from the camera (cable compensation) according to the cable lengths. (The factory default is S.) S:Less than 400 m {1 300 ft} M: 400 m {1 300 ft} to 700 m {2 300 ft} L:700 m {2 300 ft} to 900 m {3 000 ft} Note:When supplying video input signals from recorders or using cameras of other manufacturers, set VD2 and DATA to OFF. RS485 CAMERA Menu • INPUT BOARD Select a video input board from 1 to 8. (The factory default is 1.) • RS485 Select the RS-485 (CAMERA) port connecting RS-485 cam- eras. (The factory default is no settings.) CAM001 to 032:1 to 4 (INPUT BOARD=1) CAM033 to 064:5 to 8 (INPUT BOARD=2) CAM065 to 096:9 to 12 (INPUT BOARD=3) CAM097 to 128:13 to 16 (INPUT BOARD=4) CAM129 to 160:17 to 20 (INPUT BOARD=5) CAM161 to 192:21 to 24 (INPUT BOARD=6) CAM193 to 224:25 to 28 (INPUT BOARD=7) CAM225 to 256:29 to 32 (INPUT BOARD=8) • UNIT Select the unit numbers for the connected RS-485 cameras. 1 to 8 is available. Note:RS485 is not available for camera input channels accepting video input signals from recorders. To activate RS-485 camera connections, change the settings in the RECORDER menu. (Refer to p. 50.) 530 VD2/DATA/CABLE COMPENSATION 1 of 2 INPUT BOARD=8 CAM VD2 DATA CABLE CAM VD2 DATA CABLE 225 ON OFF S 233 ON OFF S 226 ON OFF M 234 ON OFF S 227 ON OFF L 235 ON OFF S 228 ON OFF S 236 ON OFF S 229 ON OFF M 237 ON ON S 230 ON OFF L 238 ON ON S 231 ON OFF S 239 ON ON S 232 ON OFF S 240 ON ON S CAM=CAMERA IN DATA:CAMERA CONTROL SIGNAL 540 RS485 CAMERA 1 of 2 INPUT BOARD=8 CAM RS485 UNIT CAM RS485 UNIT 225 29 1 233 30 1 226 29 2 234 30 2 227 29 3 235 30 3 228 29 4 236 30 4 229 29 5 237 230 29 6 238 231 29 7 239 232 29 8 240 COMMUNICATION STATUS 19200/8/ NONE/1 CAM=CAMERA IN RS485=RS485(CAMERA) 530 VD2/DATA/CABLE COMPENSATION 2 of 2 INPUT BOARD=8 CAM VD2 DATA CABLE CAM VD2 DATA CABLE 241 ON OFF S 249 OFF OFF S 242 ON OFF M 250 OFF OFF S 243 OFF OFF L 251 OFF OFF S 244 OFF OFF S 252 OFF OFF S 245 OFF OFF M 253 OFF OFF S 246 OFF OFF L 254 OFF OFF S 247 OFF OFF S 255 OFF OFF S 248 OFF OFF S 256 OFF OFF S CAM=CAMERA IN DATA:CAMERA CONTROL SIGNAL 540 RS485 CAMERA 2 of 2 INPUT BOARD=8 CAM RS485 UNIT CAM RS485 UNIT 241 31 1 249 242 32 1 250 243 251 244 252 245 253 246 254 247 255 248 256 COMMUNICATION STATUS 19200/8/ NONE/1 CAM=CAMERA IN RS485=RS485(CAMERA)
54 INFORMATION You can check whether the connected video input or output boards are working properly. When you select INFORMA- TION on the top menu, the following menu is displayed. • OUTPUT BOARD You can check the version of video output boards currently used. • INPUT BOARD ∗ are displayed beside the boards currently used. LANGUAGE You can set the desired language display for SETUP MENU. On the top menu, move the cursor to LANGUAGE and select the desired language. (Refer to p. 48 for the top menu display.) LANGUAGE:JAPANESE*, ENGLISH, FRENCH*, SPAN- ISH*, GERMAN*, ITALIAN*, RUSSIAN*. (The factory default is ENGLISH.) * In the actual display, these parameters are displayed in their own languages. 800 INFORMATION OUTPUT BOARD1 V1.00 OUTPUT BOARD2 V1.01 INPUT BOARD1 ∗ INPUT BOARD2 ∗ INPUT BOARD3 ∗ INPUT BOARD4 ∗ INPUT BOARD5 ∗ INPUT BOARD6 ∗ INPUT BOARD7 INPUT BOARD8 ∗
55 LOGIN AND LOGOUT Operator Registration Before logging into the system, operator registration is required. Operator registration is performed in Operator – Operator of WJ-SX650 Series Administrator Console. The factory default of operator information is as follows. •Operator No.:Number given for operator registration. Up to 59 operators can be registered. •User ID:ID number of operator controlling this unit. 1 to 99998 are available. Note:Begin the entry with a numeric other than 0. •Password:For login, a password is checked as well as a User ID. Up to 5 digits are available. Note:To protect system controllers from misuse, be sure to change the factory default passwords. •Level:An operators restrict level. 1 to 5 are available. 1 is the highest, and 5 is the lowest. Note:Desired functions can be assigned to each level in Operator – Level Table of WJ-SX650 Series Administrator Console. •Priority:Operator priority given to control a monitor, camera, or recorder selected by another operator. 1 to 99 are available. 1 is the highest, and 99 is the lowest. •Camera Access:View and control can be enabled or disabled for each camera. VIEW & OPERATE:An operator can display the select- ed camera image on the selected monitor. The operator can also control the camera. VIEW:An operator can display the selected camera image on the selected monitor, but cannot control the camera. - -:The operator can neither display the selected cam- era image on the selected monitor nor control the camera.•Recorder Access:View and control can be enabled or disabled for each recorder. VIEW & OPERATE:An operator can display the select- ed recorder image on the selected monitor. The operator can also control the recorder. VIEW:An operator can display the selected recorder image on the selected monitor, but cannot control the recorder. - -:The operator can neither display the selected recorder image on the selected monitor nor control the recorder. •Monitor Access:Control can be enabled or disabled for each monitor. Notes: •Monitor Access is set for each DATA port. Operators logging into the system from the same DATA port have the common setting. •Monitor Access setting is not applied for operators logging into the system from the PC connected to the SERIAL port. •Monitor Access setting is performed in Controller – Monitor Access of WJ-SX650 Series Administrator Console. Operator No. 1 650 650 1 1 View & Operate (All cameras)View & Operate (All recorders) 2 1 12345 1 1 View & Operate (All cameras)View & Operate (All recorders) 3 100 100 2 5 View & Operate (All cameras)View & Operate (All recorders) 4 101 101 3 10 View & Operate (All cameras)View & Operate (All recorders) 5 102 102 4 30 View & Operate (All cameras)View & Operate (All recorders) 6 103 103 5 50 View & Operate (All cameras)View & Operate (All recorders) User ID Password Level Priority Camera Access Recorder Access
56 Operation End (Logout) You need to log out of the system: •When finishing operations and powering off •When changing an operator WV-CU950/650 During the login status, press the LOGOUT button while holding down the SHIFT button. The LCD returns to the login standby display. WV-CU360C/CJ During the login status, press the LOG OUT button while holding down the SHIFT button. The LED display returns to the login standby display. Operation Start/End (Auto Login/Logout) •To activate auto login or auto logout, the setting is required in advance. •The auto login and auto logout settings is performed in Controller – Auto Login/Logout of WJ-SX650 Series Administrator Console. •Auto login and auto logout are set for each DATA port. Operators logging into the system from the same DATA port have the common setting. •When both auto login and auto logout are set for a DATA port, system controllers connected to the port perform login and logout automatically. Then, the sys- tem controller returns to the status before monitor selec- tion. Power-on/off 1. To power on the unit, press the power switch behind the front panel. 2. Power on system controllers and recorders. (Refer to the operating instructions of each system device for how to power on.) 3. When finishing operations, power off each device in the same procedure as power on. Operation Start (Login) By logging into the system as a registered operator, you can control system devices with the authority of that opera- tor. 1. Turn on the power. (Refer to Power-on/off.) 2. Wait until the login standby display appears. Note:If the password is wrong or no operation has been performed for 5 seconds or more, the LCD (or LED dis- play) will return to the login standby display. 3. Enter the user ID by pressing numeric buttons, and press the CAM (SET) button. 4. Enter the password by pressing numeric buttons, and press the CAM (SET) button. The system controller will enter the login status, and the LCD (or LED display) will become the default status.
57 The following is the procedure examples for monitor opera- tion. Refer to p. 73 Lists of Operations and Functions for other monitor control procedures not described here. Monitor Selection In the following procedure, you can display camera images or perform setup procedures on a desired monitor. 1. Enter the desired monitor number by pressing the numeric buttons. The entered number will appear on the LCD (or LED display). 2. Press the MON (ESC) button. The specified monitor will be selected, and the system will become ready for monitor control. 3. Control the selected monitor. Note:Even after you log out of the system or select another monitor, the camera image or sequence is continuously displayed on the selected monitor. Monitor Lock When you log out of the system or select another monitor, this function can prevent operators with lower priority from gaining control of the selected monitor and camera(s). WV-CU950/650 1. Press the MON LOCK button. The selected monitor will be locked. 2. To release the monitor lock, press the MON LOCK but- ton again. WV-CU360C/CJ 1. Press the MON LOCK button while holding down theSHIFT button. The selected monitor will be locked. 2. To release the monitor lock, press the MON LOCK but- ton again while holding down the SHIFT button. Note Monitor lock is released when you select the monitor again, or an operator with higher priority selects the monitor. MONITOR CONTROL
58 •When you select another camera or camera position, the memorized steps are updated. •When you select another monitor, the memorized steps will be cleared. WV-CU360C/CJ This operation is not available. Preset Position Control By entering preset position numbers, you can move cam- eras to preset positions. Refer to p. 73 Lists of Operations and Functions for how to register preset positions. 1. Enter the desired preset position number by pressing the numeric buttons. The entered number will appear on the LCD (or LED display). 2. Press the PRESET* 1(or CALL PRESET*2) button. The camera will move to the specified preset position. * 1WV-CU950/650 *2WV-CU360C/CJ Notes: •If you press no numeric buttons in Step 2, the cam- era will move to the home position. •By activating a group preset, two or more cameras can be moved to preset positions at a time. (Refer to p. 64.) The following is the procedure examples for camera opera- tion. Refer to p. 73 Lists of Operations and Functions for other camera control procedures not described here. Camera Selection In the following procedure, you can display the image of desired camera on the selected monitor. 1. Enter the desired camera number by pressing the numeric buttons. The entered number will appear on the LCD (or LED display). 2. Press the CAM (SET) button. The specified camera will be selected, and the system will become ready for camera control. 3. Control the selected camera. Camera Selection Recall Every time you select a camera or camera position, a sys- tem controller memorizes up to 10 steps of camera selec- tion. You can recall these steps in order or reverse order. In the following procedure, you can track back camera images or camera positions formerly displayed. WV-CU950/650 Press the – button while holding down the HISTORY button. The camera image formerly selected will be displayed on the selected monitor. (Example: Camera 128 →3) Notes: •To return to the camera images more recently selected, press the + button while holding down the HISTORY button. The camera image more recently selected will be displayed on the selected monitor. (Example: Camera 3 →128) CAMERA CONTROL
59 All Cameras Control All cameras connected to the unit can be controlled at a time. •All home positions: All cameras will be moved to the home positions. •All auxiliaries OFF: AUX 1 and 2 outputs of cameras will become OFF. Note:This operation is not available for cameras restricted by the operators setting. WV-CU950/650 1. Press the MENU button repeatedly until All CAM Control appears on the LCD. 2. Press the F1 or F3 button. Available buttons and functions F1:All home positions F3:All Auxiliaries OFF WV-CU360C/CJ This operation is not available.
60 The following is the procedure examples for recorder con- trol. Refer to p. 73 Lists of Operations and Functions for other recorder control procedures not described here. The following procedures are available when a camera is selected. Note:Depending on statuses, recorder control may not be performed properly. In this case, check the recorder status, and retry the control. Playback In the following example, you will play back the recorded image of Camera 3. 1. Check that Camera 3 has been selected. WV-CU950/650 WV-CU360C/360CJ 2. Press the PLAY/PAUSE* 1(or PLAY*2) button. The recorder connected to Camera 3 will be activated, and recorded image of Camera 3 will be played back. * 1WV-CU950/650 *2WV-CU360C/CJ WV-CU950/650 WV-CU360C/360CJ Manual Recording WV-CU950/650 Press the REC button. The recorder will be activated, and recording will be start- ed. WV-CU360C/CJ 1. Select a recorder. (Refer to p. 61 Recorder Selection.) 2. Press the ZOOM WIDE and TELE buttons. The recorder will be selected, and recording will be started. Note Recording follows the manual recording setting of recorder. Multiscreen Display WV-CU950/650 Press the MULTI SCREEN button. The recorder will be selected, and images will be displayed in multiscreen segments on the selected monitor. WV-CU360C/CJ Press the MULTI SCREEN SEL button while holding down the SHIFT button. The recorder will be selected, and images will be displayed in multiscreen segments on the selected monitor. Note You cannot specify multiscreen segment patterns. Search Playback Press the SEARCH*1(or INDEX*2) button. The recorder will be selected, and a search list (time-and- date entry form, recording event search list, VMD search list, or marking search list) will be displayed on the selected monitor. * 1WV-CU950/650 *2WV-CU360C/CJ Notes: •Depending on selected recorder disks, the search list display may differ. •In a search list, you can select a recorded image to play back. Refer to the operating instructions of recorder for operating procedures. Playing the Latest Recorded Image WV-CU950/650 Press the GO TO LAST button. The recorder will be selected, and the latest recorded image of selected camera will be played back. RECORDER CONTROL