Page 51
5051 Advanced OperationOthers IndicatorsThere are two indicators on the control panel of the projector which give information about the operating condition of the projector. These indicators illuminate or flash to warn you about problems that have occurred inside the projector, so if you notice that one of the indicators is on, turn off the power and check the table below for the cause of the problem.ProblemIndicator display Flashing (red) (Lamp unit on) The surrounding temperature or the temperature...
Page 52
5253 Others Cleaning and replacing the air filterIf the air filter becomes clogged with dust, the internal temperature of the projector will rise, the TEMP indicator will flash and the projector power will turn off. The air filter should be cleaned every 100 hours of use, depending on the location where the projector is being used.Cleaning procedure#Turn off the MAIN POWER switch and disconnect the power cord plug from the wall outlet. Turn off the MAIN POWER switch according to the procedure given in...
Page 53
5253 Others Cleaning and replacing the air filterIf the air filter becomes clogged with dust, the internal temperature of the projector will rise, the TEMP indicator will flash and the projector power will turn off. The air filter should be cleaned every 100 hours of use, depending on the location where the projector is being used.Cleaning procedure#Turn off the MAIN POWER switch and disconnect the power cord plug from the wall outlet. Turn off the MAIN POWER switch according to the procedure given in...
Page 54
5455 Others Lamp unit replacement procedureNOTE: BIf the lamp usage time has passed 2000 hours (when LAMP POWER has been set to “HIGH”), the projector will switch to standby mode after approximately 10 minutes of operation. The steps *to -on the next page should thus be completed within 10 minutes. #Turn off the MAIN POWER switch according to the procedure given in “Turning off the power” on page 23, and then disconnect the power cord plug from the wall outlet and check that the area around the lamp unit...
Page 55
5455 Others Lamp unit replacement procedureNOTE: BIf the lamp usage time has passed 2000 hours (when LAMP POWER has been set to “HIGH”), the projector will switch to standby mode after approximately 10 minutes of operation. The steps *to -on the next page should thus be completed within 10 minutes. #Turn off the MAIN POWER switch according to the procedure given in “Turning off the power” on page 23, and then disconnect the power cord plug from the wall outlet and check that the area around the lamp unit...
Page 56
5657 Others Before calling for serviceBefore asking for service, check the following points. Problem Possible cause Power does not turn on. No picture appears. The picture is fuzzy.COLOR is too light or TINT is poorNo sound can be heard.BThe power cord may not be connected. BThe MAIN POWER switch is turned off. BThe main power supply is not being supplied to the wall outlet. BTEMP indicator is illuminated or flashing. (Refer to page 51.) BLAMP indicator is illuminated or flashing. (Refer to page 52.)...
Page 57
5657 Others Before calling for serviceBefore asking for service, check the following points. Problem Possible cause Power does not turn on. No picture appears. The picture is fuzzy.COLOR is too light or TINT is poorNo sound can be heard.BThe power cord may not be connected. BThe MAIN POWER switch is turned off. BThe main power supply is not being supplied to the wall outlet. BTEMP indicator is illuminated or flashing. (Refer to page 51.) BLAMP indicator is illuminated or flashing. (Refer to page 52.)...
Page 58
5859 Others SpecificationsPower supply: 100 V–240 V ~, 50 Hz/60 Hz Power consumption: 180 W (During standby (when fan is stopped): Approx. 1.5 W) Amps: 2.2 A–0.8 A LCD panel: Panel size (diagonal): 0.7 type (17.78 mm) Aspect ratio: 16:9 Display method: 3 transparent LCD panels (RGB) Drive method: Active matrix method Pixels: PT-L300U: 518 400 (960 x 540) x 3 panels PT-L200U: 415 272 (858 x 484) x 3 panels Lens: Manual zoom (1 - 1.2) / focus lens F 2.0 - 2.3, f 22.0 mm - 26.2 mm Lamp: UHM lamp (120 W)...
Page 59
5859 Others SpecificationsPower supply: 100 V–240 V ~, 50 Hz/60 Hz Power consumption: 180 W (During standby (when fan is stopped): Approx. 1.5 W) Amps: 2.2 A–0.8 A LCD panel: Panel size (diagonal): 0.7 type (17.78 mm) Aspect ratio: 16:9 Display method: 3 transparent LCD panels (RGB) Drive method: Active matrix method Pixels: PT-L300U: 518 400 (960 x 540) x 3 panels PT-L200U: 415 272 (858 x 484) x 3 panels Lens: Manual zoom (1 - 1.2) / focus lens F 2.0 - 2.3, f 22.0 mm - 26.2 mm Lamp: UHM lamp (120 W)...
Page 60
6061 Others AppendixList of compatible signals*1 The “i” appearing after the resolution indicates an interlaced signal. *2 The following symbols are used to indicate picture quality. AA Maximum picture quality can be obtained. A Signals are converted by the image processing circuit before picture is projected B Some loss of data occurs to make projection easier. 720 x 480i 15.734 59.940 A A Video/S-Video720 x 576i 15.625 50.000 AA A Video/S-Video720 x 480i 15.734 59.940 13.500 A A YP BPR 720 x 576i...