Page 32
2.1 SAFETY PRECAUTIONS 32INSTALLATION 2.1 SAFETY PRECAUTIONS Please read the following precautions before installing the VPS. 2.1.1 Installation The VPS needs to be installed on the wall. Improper placement of the system may result in malfunction, noise, or discoloration. Avoid installing the VPS in the following places: • in direct sunlight; in hot, cold, or humid places • in new areas where there are thermal springs, etc. (where sulfuric gas may damage the equipment or contacts). • where shocks or...
Page 33
2.1 SAFETY PRECAUTIONS INSTALLATION 33 Table 7 Hard Disk Drive Usage Environment Te m p e r a t u r e: 5° C - 40° C Relative humidity: 10% - 50% Shock: Under 5 G Vibration: 5Hz - 22Hz : 0.0042cm {0.020inch} displacement; double amplitude, 1 octave per minute. 23Hz - 350Hz : Under 0.5G Magnetic Field: DC : 6gauss to 700KHz : 7milligauss 700KHz - 1.5MHz : 3milligauss
Page 34
2.2 FRAME GROUND CONNECTION 34INSTALLATION 2.2 FRAME GROUND CONNECTION IMPORTANT!!! Connect the frame of the main unit to the ground. 1.Loosen the screw. 2.Insert the grounding wire. 3.Tighten the screw. 4.Connect the grounding wire to the ground. In most of North America, the ground provided by the Third wire ground at the commercial power outlet will be satisfactory. However, in some cases this ground may be installed incorrectly. Therefore, the following test procedure should be performed. Test...
Page 35
2.2 FRAME GROUND CONNECTION INSTALLATION 35 3.Move one of the meter probes to the third prong terminal (GND). Either the same reading or a reading of 0 V should be obtained. 4.If a reading of 0 V at 1 terminal and a reading of 108 V AC-132 V AC at the other terminal is not obtained, the outlet is not properly grounded. This condition should be corrected by a qualified electrician (per article 250 of the National Electrical Code). 5.If a reading of 0 V at 1 terminal and a reading of 108 V AC-132 V AC at...
Page 36
2.3 INSTALLATION STEPS 36INSTALLATION 2.3 INSTALLATION STEPS The following is an overview of the standard installation process using DPT. When necessary, other sections in this manual have been referenced for more detailed descriptions or instructions. 1.Get a list of current users, their extension numbers, their departments, and the type of systems they use (mailbox, no mailbox, beeper, car phone...). 2.Assess your customers needs before setting up the system. You will save yourself time later by...
Page 37
2.3 INSTALLATION STEPS INSTALLATION 37 d)Connect the computer to the voice processor with a Null Modem Cable (See 2.7.2 Connecting the RS-232C Cable). e)Turn the rotary switch to position 5. f)Turn the power on. g)Wait until the warning appears on the screen. h)Turn the rotary switch back to position 0. CAUTION If the rotary switch is not returned to position 0 after initialization, all programming will be lost when the voice processor loses power! 6.Perform Quick Setup. (See Section 5 CUSTOMIZING THE...
Page 38
2.4 INSTALLING PORT EXPANSION CARD - KX-TVS100/KX-TVS200 38INSTALLATION 2.4 INSTALLING PORT EXPANSION CARD - KX- TVS100/KX-TVS200 2.4.1 General KX-TVS100 The KX-TVS100 can handle up to 4 calls simultaneously when the following port card is installed. • KX-TVS102 (2 Digital/Analog port expansion card) One port card (KX-TVS102) is installed at the factory. KX-TVS200 The KX-TVS200 can handle up to 12 calls simultaneously when the following port cards are installed. • KX-TVS102 (2 Digital/Analog port...
Page 39
2.4 INSTALLING PORT EXPANSION CARD - KX-TVS100/KX-TVS200 INSTALLATION 39 2.4.2 Installing the KX-TVS102 or KX-TVS204 Port Card Note The following five steps are for the KX-TVS200. Please refer to them for the KX-TVS100. 1.Remove the adhesive tape from the card. 2.(KX-TVS102 only) Loosen, remove and discard the screw under the tape with a screwdriver. 3.Loosen the screw on the grounding strap, then remove the strap from the unit. TVS102TVS204 SLOT 1SLOT 2 SLOT 3
Page 40
2.4 INSTALLING PORT EXPANSION CARD - KX-TVS100/KX-TVS200 40INSTALLATION 4.Insert the optional port card into SLOT 1 using the guide rails. (for the KX-TVS100, insert the optional port card into SLOT 2.) 5.Press the left and right card latches firmly, then fix the grounding strap to the unit with a screwdriver. SLOT 1SLOT 2 SLOT 3 Guide Rail TVS102 SLOT 3 SLOT 2 SLOT 1 Guide Rail TVS204 SLOT 3 SLOT 2 SLOT 1 Guide Rail TVS102