Page 391

Default Values
i2 13jDISA Delayed Answer Time1 ring
[216]Message Waiting Ring Interval Time0 min (no ring)
[2 171Timed Reminder Alarm Ring Time30 s
[218]DISA AA Wait Time1s
[2 191Call Park Recall Time12 rings
TRS / ARS Programming
[300]TRS Override for System SpeedDisable
Dialing
[301]-[305] TRS Denied Code Entry forNot Stored
Levels 2 through 6
[306]-[310] TRS Excepted Code Entry forNot Stored
Levels 2 through 6
[3 1 l]Special Carrier Access CodesNot Stored
List
5-5
. 

Page 392

520Default Values
Assignment
[402]Dial Mode SelectionAll Outside Lines=DTMF
[403]Pulse Speed SelectionAll Outside Lines=10 pps
[404] DTMF TimeAll Outside Lines=80 ms
[405]CPC Signal Detection Incoming SetAll Outside Lines=400 ms
[406]Caller ID AssignmentAll Outside Lines=Disable
[407]-[408] DLL 1: 1 Extension-Day/NightAll Outside Lines=Disable-Day/Night
[409]-[410] Intercept Extension-Day/NightAll Outside Lines=Disable-Day/Night
[41 l]Host PBX Access CodesNot Stored
f4 121 Pause TimeAll Outside Lines=l.5...

Page 393

52lDefault ValuesRinging-Day/Night
Ringing-Day/Night
[605]-[606] Outgoing Permitted OutsideAll Jacks- 1/2=All Outside
Line Assignment-Day/NightLines=Enable-Day/ Night
[607]-[608] Doorphone Ringing AssignmentJack 1-l=Enable; Other Jacks=Disable-Day/Night
-Day/Night
[609]Voice Mail Access CodesNot Stored
‘[6 171Live Call Screening Recording Mode All Jacks=Stop Ret
Assignment
Resource Programming
[800]SMDR Incoming / Outgoing Call
Outgoing Calls=All; Incoming Calls=On
Log Printout
[801] SMDR Format...

Page 394

Section 6
Troubleshooting
This section provides information for system and telephone
troubleshooting. 

Page 395

61lTroubleshooting
6.1.1 Installation
PROBLEMPROBABLE CAUSEPOSSIBLE SOLUTION
Extension does not operate.Bad printed circuit boardExchange printed circuit board for
(Extension Card).another printed circuit board.
Bad connection betweenTake the extension and plug it into
the system and extension.the same extension port using a
short telephone cord. If the
telephone does not work, the
connection between the system and
the extension must be repaired.
A telephone with an A-AlUse a 2 wire cord.
relay is...

Page 396

610Troubleshooting6.1.2 Connection
Connection between the system and a proprietary telephone:
Yes
(Continued on the
following page.)
CAUSE
The T/R is connected to the Dl/D2.
pz*xj
IIIIKX-TD308
extension
SOLUTION
Use the correct cord (inner 2
wires are for T/R and the
outer 2 wires are for Dl/D2).
Connection between the system and a standard telephone:
CAUSESOLUTION
The T/R is connected to the DlID2.
1KX-TD308
extension
Use the correct cord (inner 2
wires are for T/R).
Connection between the system and a...

Page 397

610Troubleshooting
Connection between the central office and the system:
(Continued from the
previous page.)
Outslde lmes are connected to the T2/Tl.
Can you dial
out on an
outside line?No
Outside lineKx-TD308
I
Outside lines are connected to the T2/Rl.
IOutside lineKx-TD308
6.1.3. Operation
SOLUTION
Reconnect the outside lines
totheTl/Rl orTUR2ofthe
telephone jack using 2-
conductor wiring.
PROBLEMPROBABLE CAUSE
POSSIBLE SOLUTION
l When using the speaker-. The HANDSET /l When the headset is not used,...

Page 398

61lTroubleshooting
PROBLEM
PROBABLE CAUSEPOSSIBLE SOLUTION
During a power failure,l A DPT or APT isl Disconnect the DPT or APT and
extensions connected toconnected to the jack.connect a standard telephone.
jack numbers 1 do not
l The dialing mode (tonel Set the Tone / Pulse switch to the
operate.or pulse) is improper.other position.
Originating an outside call,The corresponding COProgram the CO button. See
Call Transfer, orbutton does not exist on the
Section 4.2 
[005] “Flexible CO
Conference cannot...

Page 399

Matsushita Consumer Electronics
Company, Division of Matsushita
Electric Corporation of America
One Panasonic Way, Secaucus,
New Jersey 07094
Panasonic Saks Company (LTSC’9),
Division of Matsushita Electric of
Puerto Rico, Inc.
Ave. 65 de Infantereia, Km. 9.5,
San Gabriel Industrial Park, Carolina,
Puerto Rico 00985
Printed in the United KingdomPSQX1348ZA SO997MTO (M) 
Start reading Panasonic Kx-Td308 Digital Super Hybrid System Installation Maintenence Manual

Related Manuals for Panasonic Kx-Td308 Digital Super Hybrid System Installation Maintenence Manual

All Panasonic manuals