Page 181

2.2 System Configuration—Software
Feature Guide 181
Operator Call
An extension user can call an operator by dialing the preprogrammed Operator Call feature 
number, often simply, 0. When an Operator Call is made, the call is directed to the tenant 
operator of the calling extension’s tenant. If no tenant operator is assigned, the call is routed to 
the PBX operator. The tenant number of the calling extension determines the current time 
mode which is then used to determine the current PBX operator.
If...

Page 182

2.2 System Configuration—Software
182 Feature Guide
Conditions
WARNINGWhen a third party discovers the personal identification number (PIN) (verified code PIN/
extension PIN) of the PBX, there will be a risk that they will make fraudulent phone calls 
using the telephone line, and the cost will be charged to your own account. In order to 
avoid this problem, we strongly recommend the following points:
a)Carefully maintain the secrecy of the PIN.
b)Specify a complicated PIN as long and random as you can...

Page 183

2.2 System Configuration—Software
Feature Guide 183
Manager Password
Only one manager password can be assigned per PBX (  Manager Password [112]).
User Manual References
User Manual
2.1 Control Features
3.2.2 Manager Programming 

Page 184

2.3 System Data Control
184 Feature Guide
2.3 System Data Control
2.3.1 PC Programming
Description
Although many PBX features can be programmed using a proprietary telephone (PT) (  2.3.2 
PT Programming), a PC connected to the PBX can use the KX-TAW848 Maintenance Console 
software to program in further detail. System programming, diagnosis, and data upload/
download can be performed either through on-site programming or remote programming.
1)On-site Programming: Programming that is performed using an...

Page 185

2.3 System Data Control
Feature Guide 185
2.Connection Methods for Remote Programming
Conditions
Only one system programming session is permitted at a time. Access will be denied when 
a second party tries to perform system programming, including system programming via 
a PT.
Programmer Code and Password for System Programming
To access system programming, a programmer code (login ID for the programmer) and its 
password must be entered. There are three programmer codes, which are set at the 
factory...

Page 186

2.3 System Data Control
186 Feature Guide
programming (Default: None [no limitation]), access will be locked and can only be 
unlocked by enabling remote access once again through on-site system programming (  
Remote Programming [810]).
Remote Programming Limitation
It is possible to disable remote access through system programming (  Remote 
Programming [810]). Disabling this feature will also disable the ability to perform on-site 
programming via modem.
If an extension user sets Walking Extension...

Page 187

2.3 System Data Control
Feature Guide 187
Conditions
Class of Service (COS) programming determines the level of programming an extension 
user is authorized to perform (  Programming Mode Limitation [516]):
The extension which is connected to the lowest numbered port on the card installed in the 
lowest numbered slot can perform both personal programming and system programming 
regardless of the extension’s COS.
COS programming determines which extensions are manager extensions and can 
therefore...

Page 188

2.3 System Data Control
188 Feature Guide
Feature Guide References
2.2.6 Manager Features
3.3 PT Programming
User Manual References
User Manual
3.1 Personal Programming
3.2 Manager Programming
3.3 System Programming
2.3.3 Quick Setup
Description
Basic PBX parameters can be programmed the first time the PBX is accessed with a PC using 
the KX-TAW848 Maintenance Console software.
 When the PBX is accessed with the Installer Level Programmer Code and default password 
(  2.3.1 PC Programming), for the first...

Page 189

2.3 System Data Control
Feature Guide 189
2.3.4 Automatic Time Adjustment
Description
The PBX clock can be adjusted automatically in the following two ways:
1.Daylight Saving Time Setting
The start and end dates of Daylight Saving Time can be programmed. The PBX clock will 
automatically adjust itself one hour forward or backward at 2:00 A.M. on the programmed 
date, if enabled through system programming. At 2:00 A.M. on the start date, the clock will 
change to 3:00 A.M., and at 2:00 A.M. on the end...

Page 190

2.3 System Data Control
190 Feature Guide
2.3.5 Flexible Numbering/Fixed Numbering
Description
To dial another extension user or to access PBX features, access numbers (extension numbers 
or feature numbers) are required.
There are three types of numbering plans:
1)Flexible Numbering (available while a dial tone is heard)
2)Flexible Numbering (available while a busy, DND, or ringback tone is heard)
3)Fixed Numbering (available while dialing or talking)
1.Flexible Numbering (available while a dial tone is...