Page 181
2.2 System Configuration—Software Feature Guide 181 Operator Call An extension user can call an operator by dialing the preprogrammed Operator Call feature number, often simply, 0. When an Operator Call is made, the call is directed to the tenant operator of the calling extension’s tenant. If no tenant operator is assigned, the call is routed to the PBX operator. The tenant number of the calling extension determines the current time mode which is then used to determine the current PBX operator. If...
Page 182
2.2 System Configuration—Software 182 Feature Guide Conditions WARNINGWhen a third party discovers the personal identification number (PIN) (verified code PIN/ extension PIN) of the PBX, there will be a risk that they will make fraudulent phone calls using the telephone line, and the cost will be charged to your own account. In order to avoid this problem, we strongly recommend the following points: a)Carefully maintain the secrecy of the PIN. b)Specify a complicated PIN as long and random as you can...
Page 183
2.2 System Configuration—Software Feature Guide 183 Manager Password Only one manager password can be assigned per PBX ( Manager Password [112]). User Manual References User Manual 2.1 Control Features 3.2.2 Manager Programming
Page 184
2.3 System Data Control 184 Feature Guide 2.3 System Data Control 2.3.1 PC Programming Description Although many PBX features can be programmed using a proprietary telephone (PT) ( 2.3.2 PT Programming), a PC connected to the PBX can use the KX-TAW848 Maintenance Console software to program in further detail. System programming, diagnosis, and data upload/ download can be performed either through on-site programming or remote programming. 1)On-site Programming: Programming that is performed using an...
Page 185
2.3 System Data Control Feature Guide 185 2.Connection Methods for Remote Programming Conditions Only one system programming session is permitted at a time. Access will be denied when a second party tries to perform system programming, including system programming via a PT. Programmer Code and Password for System Programming To access system programming, a programmer code (login ID for the programmer) and its password must be entered. There are three programmer codes, which are set at the factory...
Page 186
2.3 System Data Control 186 Feature Guide programming (Default: None [no limitation]), access will be locked and can only be unlocked by enabling remote access once again through on-site system programming ( Remote Programming [810]). Remote Programming Limitation It is possible to disable remote access through system programming ( Remote Programming [810]). Disabling this feature will also disable the ability to perform on-site programming via modem. If an extension user sets Walking Extension...
Page 187
2.3 System Data Control Feature Guide 187 Conditions Class of Service (COS) programming determines the level of programming an extension user is authorized to perform ( Programming Mode Limitation [516]): The extension which is connected to the lowest numbered port on the card installed in the lowest numbered slot can perform both personal programming and system programming regardless of the extension’s COS. COS programming determines which extensions are manager extensions and can therefore...
Page 188
2.3 System Data Control 188 Feature Guide Feature Guide References 2.2.6 Manager Features 3.3 PT Programming User Manual References User Manual 3.1 Personal Programming 3.2 Manager Programming 3.3 System Programming 2.3.3 Quick Setup Description Basic PBX parameters can be programmed the first time the PBX is accessed with a PC using the KX-TAW848 Maintenance Console software. When the PBX is accessed with the Installer Level Programmer Code and default password ( 2.3.1 PC Programming), for the first...
Page 189
2.3 System Data Control Feature Guide 189 2.3.4 Automatic Time Adjustment Description The PBX clock can be adjusted automatically in the following two ways: 1.Daylight Saving Time Setting The start and end dates of Daylight Saving Time can be programmed. The PBX clock will automatically adjust itself one hour forward or backward at 2:00 A.M. on the programmed date, if enabled through system programming. At 2:00 A.M. on the start date, the clock will change to 3:00 A.M., and at 2:00 A.M. on the end...
Page 190
2.3 System Data Control 190 Feature Guide 2.3.5 Flexible Numbering/Fixed Numbering Description To dial another extension user or to access PBX features, access numbers (extension numbers or feature numbers) are required. There are three types of numbering plans: 1)Flexible Numbering (available while a dial tone is heard) 2)Flexible Numbering (available while a busy, DND, or ringback tone is heard) 3)Fixed Numbering (available while dialing or talking) 1.Flexible Numbering (available while a dial tone is...