Panasonic Kx Ta824 Programming Manual
Have a look at the manual Panasonic Kx Ta824 Programming Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
9.2 Extension [2] Programming Manual 161 Value Range Log-in, Log-out Feature Manual References 1.1.80 Log-in/Log-out Operating Manual References 1.3.59 Log-in/Log-out MW for Another Ext. Lock Enables the authorization to lock message waiting indications to prevent others from viewing, calling back or clearing message waiting indications left at a users extension. If this setting is enabled, the code to lock and unlock message waiting indications can be specified. Default All jacks: Off Value Range lock, code lock: On (checked), Off (unchecked) code: 4 digits (4000–9999) Feature Manual References 1.1.83 Message Waiting for Another Extension Operating Manual References 1.3.62 Message Waiting for Another Extension Lock Paging Deny Enables the prevention of being paged by other extensions. Default All jacks: Off Value Range On (checked), Off (unchecked) Feature Manual References 1.1.92 Paging—SUMMARY Operating Manual References 1.3.73 Paging Deny
9.2 Extension [2] 162 Programming Manual Monitored PT set This program is available only for the extensions enabled in Room Monitor on the 9.2.1 Main [2-1] screen. To set the Room Monitor feature at the monitored extension, select the check box for the extension in this program, and then press the AUTO ANS button of the extension to be monitored. Default All jacks: Off Value Range On (checked), Off (unchecked) Programming Manual References 9.2.1 Main [2-1]—Room Monitor Feature Manual References 1.1.110 Room Monitor Operating Manual References 1.3.80 Room Monitor LCS Password Specifies the Live Call Screening (LCS) password to prevent the unauthorized screening of calls. Default All jacks: — (Not stored) Value Range 3 digits (consisting of 0–9) Feature Manual References 1.1.77 Live Call Screening (LCS) (Voice Mail APT Integration only) Operating Manual References 1.3.56 Live Call Screening (LCS) (Voice Mail APT Integration only)
9.2 Extension [2] Programming Manual 163 Page 3 Jack Indicates the jack number (reference only). Value Range 01–24 Extension Indicates the extension number and name (reference only). Value Range Extension no. and name specified in Ext. no. and Name on the 9.1.3 Numbering Plan [1-3] screen Programming Manual References 9.1.3 Numbering Plan [1-3]—Ext. no., Name Hot Line for SLT Enables the Hot Line feature. Default All jacks: Off [set], — (Not stored) [phone no.] Value Range set, phone no. set: On (checked), Off (unchecked) phone no: Max. 32 digits (consisting of 0–9, , and P [pause])
9.2 Extension [2] 164 Programming Manual Feature Manual References 1.1.66 Hot Line Operating Manual References 1.3.50 Hot Line Timed Reminder Enables the Timed Reminder feature. When One Time or Daily is selected, the setting time can be specified. Default All jacks: Cancel Value Range Cancel, One Time (AM12:00–PM11:59), Daily (AM12:00–PM11:59) Feature Manual References 1.1.115 Timed Reminder 1.1.116 Timed Reminder, Remote Operating Manual References 1.3.84 Timed Reminder 2.1.10 Timed Reminder, Remote (Wake-up Call) Voice Mail Integration Selects the Follow-on ID format required by your Voice Processing System (VPS). Default All jacks: B: send #6+ext no. Value Range Cancel, A: send ext no., B: send #6+ext no. Feature Manual References 1.1.121 Voice Mail Inband (DTMF) Integration Operating Manual References 1.3.88 Voice Mail Integration 9.2.3 PT personal settings [2-3] Various personal programming settings on a proprietary telephone (PT) can be programmed for each extension. This screen is divided into 2 pages, each containing different settings. To show all parameters for a certain jack or extension, double-click the relevant Jack or Extension Number cell.
9.2 Extension [2] Programming Manual 165 Page 1 Jack Indicates the jack number (reference only). Value Range 01–24 Extension Indicates the extension number and name (reference only). Value Range Extension no. and name specified in Ext. no. and Name on the 9.1.3 Numbering Plan [1-3] screen Programming Manual References 9.1.3 Numbering Plan [1-3]—Ext. no., Name Line Preference—Outgoing Selects the line to be seized after going off-hook to make a call. Default All jacks: No Line Value Range No Line, Idle Line, CO 1–8
9.2 Extension [2] 166 Programming Manual Feature Manual References 1.1.76 Line Preference—Outgoing Operating Manual References 3.1.2 Personal Feature Assignment—Line Preference—Outgoing Line Preference—Incoming Selects the line on which an incoming call is answered after going off-hook. Default All jacks: Ringing Line Value Range No Line, Ringing Line, CO 1–8 Feature Manual References 1.1.75 Line Preference—Incoming Operating Manual References 3.1.2 Personal Feature Assignment—Line Preference—Incoming CO Line Ringing Selection—CO1–8 Specifies whether an extension will ring when receiving a call from an outside (CO) line. Default All jacks: On Value Range On (checked), Off (unchecked) Feature Manual References 1.1.90 Outside (CO) Line Ringing Selection Operating Manual References 3.1.2 Personal Feature Assignment—Outside (CO) Line Ringing Selection
9.2 Extension [2] Programming Manual 167 Page 2 Jack Indicates the jack number (reference only). Value Range 01–24 Extension Indicates the extension number and name (reference only). Value Range Extension no. and name specified in Ext. no. and Name on the 9.1.3 Numbering Plan [1-3] screen Programming Manual References 9.1.3 Numbering Plan [1-3]—Ext. no., Name Extension Password Specifies the extension password used for the Walking COS feature and the Remote Extension Lock feature. The extension password should be unique to that extension. Default All jacks: — (Not stored)
9.2 Extension [2] 168 Programming Manual Value Range 4 digits (consisting of 0–9) Feature Manual References 1.1.87 Operator/Manager Features Operating Manual References 2.1.7 System Feature Assignment—Extension Password Set (Manager only) Alternate Receiving Selects the method of receiving intercom calls. Default All jacks: Tone Call Value Range Tone Call, Voice Call Feature Manual References 1.1.69 Intercom Call Operating Manual References 3.1.2 Personal Feature Assignment—Alternate Receiving—Ring/Voice Call Waiting Tone Type Selects the type of Call Waiting tone to receive when an extension is busy and a new call arrives. Default All jacks: Tone 1 Value Range Tone 1, Tone 2 Feature Manual References 1.1.27 Call Waiting Operating Manual References 3.1.2 Personal Feature Assignment—Call Waiting Tone Type Selection LCS Mode Selects whether the extensions mailbox is monitored in Hands-free or Private mode. Default All jacks: Hands-free
9.2 Extension [2] Programming Manual 169 Value Range Hands-free, Private Hands-free: The extension user can screen calls automatically through the built-in speaker. Private: The extension user will hear an alert tone when a message is being recorded in his or her mailbox. To screen calls, the extension user must press the MONITOR, SP-PHONE, or LCS button. Feature Manual References 1.1.77 Live Call Screening (LCS) (Voice Mail APT Integration only) Operating Manual References 3.1.2 Personal Feature Assignment—Live Call Screening (LCS) Mode Set 9.2.4 Flexible Buttons [2-4] Each flexible CO, Programmable Feature (PF), or MESSAGE button can be customized to allow one-touch access to a certain feature. The button settings of an extension can be copied to other extensions. Select the extension whose buttons you want to copy from the Extension jack list, then click Copy. Clicking a CO button opens the 9.2.5 Flexible Buttons [2-4] CO buttons screen, which allows you to specify the feature to be assigned to a flexible CO button on the selected extension. Clicking a PF button opens the 9.2.6 Flexible Buttons [2-4] PF buttons screen, which allows you to specify the feature to be assigned to a PF button on the selected extension. Clicking the Message button opens the 9.2.7 Flexible Buttons [2-4] Message button screen, which allows you to specify the feature to be assigned to the MESSAGE button on the selected extension. Extension jack Selects the jack number of the extension to edit. The extension number and name are shown with the jack number. Value Range Jack 01–24 (Extension no. and name specified in Ext. no. and Name on the 9.1.3 Numbering Plan [1-3] screen)
9.2 Extension [2] 170 Programming Manual Programming Manual References 9.1.3 Numbering Plan [1-3]—Ext. no., Name CO buttons Each CO button can be customized to access a certain feature with a one-touch operation. Default Button 1–8: Single CO (CO Line Number 1–8), Button 9–12: Not Stored Value Range Not Stored, Single CO, Group CO, Direct Station Selection (DSS), One-touch Dialing, Other CO, Conference, FWD/DND, Saved Number Redial, Caller ID Indication—Personal, Caller ID Selection— Personal, Log-in/Log-out, 2-way Record, 2-way Transfer, Live Call Screening (LCS), LCS Cancel, Voice Mail Transfer, Another Extension Message Waiting, Caller ID Indication—Common, Caller ID Selection— Common Programming Manual References 9.2.5 Flexible Buttons [2-4] CO buttons Feature Manual References 1.1.61 Flexible Buttons Operating Manual References 3.1.3 Flexible Button Assignment PF buttons Each PF button can be customized to access a certain feature with a one-touch operation. Default All buttons: Not Stored Value Range Not Stored, One-touch Dialing Programming Manual References 9.2.6 Flexible Buttons [2-4] PF buttons Feature Manual References 1.1.61 Flexible Buttons Operating Manual References 3.1.3 Flexible Button Assignment Message button The Message button can be customized to access a certain feature with a one-touch operation.