Home > Panasonic > Camera Accessories > Panasonic Indoor Pan Tilt Head Aw Ph400 Operating Instructions

Panasonic Indoor Pan Tilt Head Aw Ph400 Operating Instructions

Here you can view all the pages of manual Panasonic Indoor Pan Tilt Head Aw Ph400 Operating Instructions . The Panasonic manuals for Camera Accessories are available online for free. You can easily download all the documents as PDF.

Page 41

Cable Compensator  AW-RC400
40 (E)
ENGLISH 

Page 42

Roll Unit  AW-RL400
41 (E)
Introduction
Accessories
≥The AW-RL400 roll unit enables a camera to be rotated
when it is used in combination with the AW-PH400 indoor
pan/tilt head.NOTE
≥Since the roll unit causes the camera to rotate, the user
should ensure that all the wiring such as the camera
cable and lens cable will not become entangled when
the roll unit is operated.
≥When the roll unit is to be discarded at the end of its
service life, ask a specialized contractor to dispose of it
properly in order...

Page 43

Roll Unit  AW-RL400
42 (E)
ENGLISH
Parts and their function
1Rotary ring
2Camera mounting screw (U1/4”-20UNC)
After mounting the camera, secure it firmly using this
screw.
3Camera mounting plate
Mount the camera on this plate using the camera
mounting screws.
4Camera mounting plate anchoring screws
After mounting the camera on the camera mounting
plate, anchor it to the roll unit using these screws.
5Roll unit anchoring screw holes
This is where the roll unit is secured to the rotary arm of
the pan/tilt...

Page 44

Roll Unit  AW-RL400
43 (E)
Installation
4Attach the camera mounting plate (it was removed in step 3) to the camera unit using two camera mounting screws (camera
accessory). 3Loosen the two screws of camera mounting plate which is already installed to the roll unit.
Then remove the camera mounting plate. 1Attach the pan/tilt head’s rotary arm to the roll unit using the accessory three screws (M4!8 mm, with flat washers).
2Attach the rotary arm to the pan/tilt head using the rotary arm mounting screws...

Page 45

Roll Unit  AW-RL400
44 (E)
ENGLISH
Specifications
Pan/tilt head connector:Connected to pan/tilt head using cable supplied
Performance:Maximum load-bearing capability: 4 kg
Rotary range: 380 degrees (approx. ±190 degrees)
Maximum operating speed: 60 degrees/sec.
Repeatability: Less than ±1 degree
Noise level: Less than ???
Ambient operating temperature:0°C to +40°C
Storage temperature:–20°C to +60°C
Ambient operating humidity:30% to 90% (no condensation)
Dimensions (W!H!D):205!198!260 mm
Weight:Approx....

Page 46

45 (E)
Connections
≥Turn off the power of all the equipment before proceeding with the connections.
≥Use the AW-PS505 as the AC adaptor for the AW-RP400 pan/tilt head controller. Use the DC cable supplied
with the AW-PS505 to connect the DC 12V IN socket on the AW-RP400 with the DC 12V OUT socket on the
AW-PS505.
≥Connect the AC power cable supplied with the AW-PH400 for the AW-PH400 indoor pan/tilt head.
≥Use the AC adaptor supplied with the AW-RC400 for the AW-RC400 cable compensator.
≥Use 10BASE-T...

Page 47

46 (E)
ENGLISH
Connections
Motorized zoom lens
Iris control
Convertible camera
Genlock signals
Video signals
Video signal output
Genlock signal input
Monitor switching signals
Monitor signals 1
Monitor for AW-CB400Monitor for AW-RP400
Monitor signals 2Camera cable supplied
with AW-PH400 Zoom/focus control
AW-PH400 indoor
pan/tilt head
Pan/tilt head/camera
control signals
AC power cable supplied
with AW-PH400
AW-RP400 pan/tilt
head controller AW-CB400 remote
operation panel
Cable supplied with AW-CB400...

Page 48

47 (E)
Example of system configuration
Convertible camera
MONITOR1
MonitorMonitor
Cable provided with AW-CB400 Monitor switching
AW-RC400 cable
compensator
AW-PS505
AC adaptor
Pan/Tilt Head Controller
AW-RP400Remote operation
panel
AW-CB400 Headset
Headset
MONITOR2
Pan/tilt head and camera control Indoor Pan/Tilt Head 
AW-PH400
Composite video or
component video
signals
To switcher,
monitor
Genlock signalsG/L
AW-PS301
AC adaptor 

Page 49

48 (E)
ENGLISH
Operating procedures
$Turning on the power
1When using one AW-RP400, set its EXT CONT [M/S] switch to the [M] position.
2Turn on the power.
First set the power switch on the AC adaptor for the AW-RP400 and AC power switch on the AW-PH400 to ON, and then
set the OPERATE switch on the AW-RP400 to ON.
$Setting the movement range (limiters) of the AW-PH400 indoor pan/tilt head
If there are any objects obstructing the movement of the AW-PH400 indoor pan/tilt head in the immediate vicinity, set...

Page 50

49 (E)
Operating procedures
6To set the counterclockwise limit of the roll unit, use the ROTATION switch to rotate the roll unit as far as the limit in the
counterclockwise direction which is to be set.
While holding down the MENU/LIMIT button, press the PRESET MEMORY button [25].
Once the limit is set, the lamp of the PRESET MEMORY button [45] will light.
To release the setting, press the PRESET MEMORY button [25] again while holding down the MENU/LIMIT button.
Once the setting is released, the lamp of...
Start reading Panasonic Indoor Pan Tilt Head Aw Ph400 Operating Instructions