  Color Correction 1/3
  B_Mg Gain             0
  B_Mg Phase            0
  Mg   Gain           +27
  Mg   Phase            0
  Mg_R Gain             0
  Mg_R Phase            0
  R    Gain           +15
  R    Phase            0
 Return
 Color Correction Set Display
  Color Correction 2/3
  R_Yl Gain             0
  R_Yl Phase            0
  Yl   Gain           +18
  Yl   Phase           +6
  Yl_G Gain             0
  Yl_G Phase            0
  G    Gain           +30
  G    Phase         +112...

Page 72

- 72 -
   Other Set 1
  Gamma              0.45
  Knee Point          88%
  White Clip         110%
  Flare R               0
  Flare G               0
  Flare B               0
  Black Stretch       Off
  SD 2D LPF           Off
  EBU Matrix Set      Off
 Return–––––––––––––––––––––
––––––
–––––––––––––––––––––
 Other Set Display
   Other Set 2
  Format            1080i
  Downconv. Mode  Squeeze
  Component       Y/Pb/Pr
  Status              Off
  Character Mix
   Component           On...

Page 73

- 73 -
Description of the setting screen
 Brightness  Set
  Video level adjustment
[Picture Level: –50 to +50]
Convergence level of AUTO IRIS, AUTO GAIN UP and 
ELC can be adjusted.
  Detecting ratio adjustment
[Light PEAK/AVG: P50 to A50]
The ratio of AUTO IRIS, AUTO GAIN UP and ELC 
detected peak (P) to average (A) can be adjusted within a 
predetermined range.
  Photometric measurement method setting 
[Light Area: All, Center, Top Cut, BTM Cut, 
R/L Cut]
A photometric measurement method can be...

Page 74

- 74 -
  Electronic shutter step/synchro scan setting 
[Step/Synchro: Off, 1/100 to 1/10000 (Step), 
61.19 Hz to 1466 Hz (Synchro Scan)]
This setting is possible only when “Step” or “S/Scan” is 
selected in electronic shutter mode setting.
When “Step” has been selected as the electronic shutter 
mode setting:
  Off:  Electronic shutter is turned off.
  1/100, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000:
     Electronic shutter operates at one of these 
speeds as selected.
 When “S/Scan” has been...

Page 75

- 75 -
 Color  Set
  Chroma level adjustment
[Chroma Level: –3 to +3]
Chroma Level can be decreased or increased to any of 
three levels each.
The RGB signal cannot be adjusted.
  White balance setting
[White Bal: ATW, AWB A, AWB B, 3200K, 5600K]
AT W :   The white balance is automatically adjusted to 
the optimum position.
The white balance is tracked across an 
approximate color temperature range from 
2000K to 10000K.
AWB A, AWB B:
   Once the white balance is adjusted, it is no 
longer necessary...

Page 76

- 76 -
 HD (1080i, 720p) Detail Set
 Detail level setting [Detail: Off, Low, High]
Contour correction quantity can be selected.
Detail settings made using the horizontal/vertical detail 
level high/low setting.
  Horizontal detail level high setting
[H Detail Level H: L+1 to +63]
   Vertical detail level high setting
[V Detail Level H: L+1 to +31]
   Horizontal detail level low setting
[H Detail Level L: 0 to H–1]
   Vertical detail level low setting
[V Detail Level L: 0 to H–1]
Detail level can be...

Page 77

- 77 -
  Dark detail level setting
[Dark Detail: 0 to 5]
The contours of the darker portions of an object can be 
emphasized.
This setting is possible only when the level dependent 
level setting is set to “0 %”.
  Chroma detail level setting
[Chroma Detail: 0 to 15]
The contours of high-hue portions of an object can be 
emphasized.
  Clean DNR setting
[Clean DNR: Off, Low, High]
The noise reduction effect to be provided by the clean 
DNR can be selected.
  Flesh noise suppress level setting
[Flesh...

Page 78

- 78 -
 SD (480i) Detail Set
 Detail level setting [Detail: Off, Low, High]
Contour correction quantity can be selected.
Detail settings made using the horizontal/vertical detail 
level high/low setting.
  Horizontal detail level high setting
[H Detail Level H: L+1 to +63]
   Vertical detail level high setting
[V Detail Level H: L+1 to +31]
   Horizontal detail level low setting
[H Detail Level L: 0 to H–1]
   Vertical detail level low setting
[V Detail Level L: 0 to H–1]
Detail level can be set in...

Page 79

- 79 -
Menu item setting/changing (User Mode)
  Dark detail level setting
[Dark Detail: 0 to 5]
The contours of the darker portions of an object can be 
emphasized.
This setting is possible only when the level dependent 
level setting is set to “0 %”.
  Chroma detail level setting
[Chroma Detail: 0 to 15]
The contours of high-hue portions of an object can be 
emphasized.
  Clean DNR setting
[Clean DNR: Off, Low, High]
The noise reduction effect to be provided by the clean 
DNR can be selected.
...

Page 80

- 80 -
Menu item setting/changing (User Mode)
 Color Matrix Set
  Linear Matrix R-G
[Matrix(R-G): –31 to +31]
This is used to adjust the color in the R-G axis direction.
  Linear Matrix R-B
[Matrix(R-B): –31 to +31]
This is used to adjust the color in the R-B axis direction.
  Linear Matrix G-R
[Matrix(G-R): –31 to +31]
This is used to adjust the color in the G-R axis direction.
  Linear Matrix G-B
[Matrix(G-B): –31 to +31]
This is used to adjust the color in the G-B axis direction.
  Linear Matrix B-G...
Start reading Panasonic Hd Convertible Camera Aw He870n Operating Instructions

Related Manuals for Panasonic Hd Convertible Camera Aw He870n Operating Instructions

All Panasonic manuals