66 DST Here you can set day night save time begin time and end time. You can set according to the date format or according to the week format. NTP You can check the box to enable NTP function. NTP server You can set the time server address. Port It is to set the time server port. Update period It is to set the sync periods between the device and the time server. 4.4.2 Account For the character in the following user name or the user group name, system max supports 15- digits. The valid string includes: character, number, and underline. Password can be 0~32 characters in number and letter only. User can modify other user’s password. The user amount is 18 and the group amount is 8 when the device is shipped out of the factory. The factory default setup includes two levels: user and admin. You can set the corresponding group and then set the rights for the respective user in the specified groups. User management adopts group/user modes. The user name and the group name shall be unique. One user shall be included in only one group. Currently logged in user cannot change his/her own right. 4.4.2.1 Username In this interface you can enable anonymity login, add/remove user and modify user name. See Figure 4- 54.
![](/img/blank.gif)
67 Figure 4-54 Enable anonymity login: Enable anonymity login, and input IP. No username or password is required, you can log in by anonymity (with limited rights). You can click logout to end your session. Add user: It is to add a name to group and set the user rights. See Figure 4- 55. Hidden user “default” is for system interior use only and cannot be deleted. When there is no login user, hidden user “default” automatically login. You can set some rights such as monitor for this user so that you can view some channel view without login. Here you can input the user name and password and then select one group for current user. Please note the user rights shall not exceed the group right setup. For convenient setup, please make sure the general user has the lower rights setup than the admin.
![](/img/blank.gif)
68 Figure 4- 55 Modify user It is to modify the user property, belonging group, password and rights. See Figure 4-56. Modify password It is to modify the user password. You need to input the old password and then input the new password twice to confirm the new setup. Please click the OK button to save. Please note, the password ranges from 0-digit to 32-digit. It shall include the number and letter only. For the user who has the account rights, he can modify the password of other users.
![](/img/blank.gif)
69 Figure 4-56 4.4.2.2 Group The group management interface can add/remove group, modify group password and etc. The interface is shown as in Figure 4- 57.
![](/img/blank.gif)
70 Figure 4- 57 Add group: It is to add group and set its corresponding rights. See Figure 4- 58. Please input the group name and then check the box to select the corresponding rights. It includes: preview, playback, record control, PTZ control and etc. Figure 4- 58 Modify group Click the modify group button, you can see an interface is shown as in Figure 4-59.
![](/img/blank.gif)
71 Here you can modify group information such as remarks and rights. Figure 4-59 4.4.3 Default The default setup interface is shown as in Figure 4- 60. Please note system cannot restore some information such as network IP address. Figure 4- 60 4.4.4 Import/Export The interface is shown as in Figure 4- 61.
![](/img/blank.gif)
72 Figure 4-61 Please refer to the following sheet for detailed information. Parameter Function Import It is to import the local setup files to the system. Export It is to export the corresponding system setup to your local PC. 4.4.5 Auto Maintenance The auto maintenance interface is shown as in Figure 4-62. Here you can select auto reboot and auto delete old files interval from the dropdown list. If you want to use the auto delete old files function, you need to set the file period. Figure 4-62
![](/img/blank.gif)
73 Parameter Function Auto Reboot Check it and set auto reboot time. Auto Delete Old Files Check it and set period within 1~31 days. 4.4.6 Upgrade The upgrade interface is shown as in Figure 4-63. Please select the upgrade file (file extension is “.bin”) and then click the update button to begin firmware update. Important Improper upgrade program may result in device malfunction! Figure 4-63 4.5 Information 4.5.1 Version The version interface is shown as in Figure 4-64. Here you can view system hardware features, software version, release date and etc. Please note the following information is for reference only.
![](/img/blank.gif)
74 Figure 4-64 4.5.2 Log Here you can view system log. See Figure 4-65. Figure 4-65 Please refer to the following sheet for log parameter information. Parameter Function Start time Set the start time of the requested log. (The earliest time is 2000/1/1) End time Set the end time of the requested log. (The latest time is 2037/12/31) Type Log type.
![](/img/blank.gif)
75 Parameter Function Search You can select log type from the drop down list and then click search button to view the list. You can click the stop button to terminate current search operation. Log information You can select one item to view the detailed information. Clear You can click this button to delete all displayed log files. Please note system does not support clear by type. Backup You can click this button to backup log files to current PC. 4.5.3 Online User The online user interface is shown as in Figure 4-66. Here you can view current online user, group name, IP address and login time. Figure 4-66